116.5 70 Rc(PT) 1, 1 Rc(PT) 1 25 VEX5710 VEX5711 1 4 1 4 177.5 167.5 84.5 90 60 30 15 7 190.5 54.5 100 13 105.5 103.5 18 4-M6 X 1 X depth 6 136.5 60 17 82 c Bracket mounting dimensions h Grommet terminal i Conduit terminal g Grommet j DIN connector a Model b d e f VEX5510 VEX5511 19 130 110 9 12 2.3 204 204.5 222 221.5 32 VEX5710 VEX5711 136 9 20 2.3 120 221.5 239.5 221 239 VEX5910/5911
If the mounting surface is distorted or not flat, excessive force may be applied to the housing, etc. causing malfunction. 19 - 4.
(mm) Bore size A B C D F FB FC FT FX FY FZ GA GB H MM NA NB NN S Z 10 15 12 14 4 8 13 4.5 1.6 24 14 32 8 5 28 M4 x 0.7 12.5 9.5 M8 x 1.0 46 74 16 15 18.3 20 5 8 19 5.5 2.3 33 20 42 8 5 28 M5 x 0.8 12.5 9.5 M10 x 1.0 47 75 5 Series CJ2Y Dimensions Head flange (G) CJ2YG Bore size Stroke Z Mounting nut MM NN GA Piping port 2 x M5 x 0.8 GB NN Cover surface Rod end nut C D B 0 0.3 FY FB 2 x
UNF 0.625 0.75 1.12 0.38 0.88 0.34 0.62 0.81 0.12 1.00 1/8 1.00 0.093 0.22 1/4-28 10-32 UNF 1/4-20 0.250 106 (1 1/16") 10-32 UNF 0.750 0.75 1.47 0.62 1.22 0.47 0.81 0.24 1.12 1.25 1/8 1.25 0.093 0.25 3/16-24 10-32 UNF 1/4-20 0.312 150 (1 1/2") 1/4-20 NUC 1.00 1.25 1.93 0.88 1.57 0.38 1.12 1.56 0.25 1.75 1/4 1.75 0.125 0.38 7/16-20 1/4-20 NUC 5/16-18 0.437 Block Mounting Type (in) ZB2 ZB3
28 49 35 28 16.8 2.7 12 PF3W711 3/41 124 92 46 77 57.6 23 41 42 63 48 28 18 3.5 14 S T U V W WX Y Z PF3W704 24 22 32 40 50 4.5 5 1.5 PF3W720 28 22 32 40 50 4.5 5 1.5 PF3W740 34 30 42 48 58 4.5 5 1.5 PF3W711 44 36 48 58 70 5.5 7 2 -81No.PF-OMM0004-D PF3W721 A AA B D E F G H J K L N P 11/4,11/2 104 74 31 52 39.5 G 11/4 108 76 33 54 41.5 PF3W721 56 91 71.6 28.5 54 25 27.5 3.5 14 G 11/2 112
13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 51 Revision history G: Revise Safety Instructions.
EMG+ 1 EMG+ 1 EMG2 EMG2 SD+ 3 SD+ 3 SD4 SD4 EN_SW+ 5 EN_SW+ 5 ON 6 ON 6 DC24V 7 DC24V 7 GND 8 GND 8 Shield Shield 32 - 9. CN2: TB/PC connector 9. 1 How to use This connector is for setting the controller (LEC) which is connected to the gateway unit by the teaching box or the set software.
55.9 25 24 18.5 12 (P port) Rc 1/8,1/4 A B (A port) Rc 1/8,1/4 Base mounted: VPA344V12 65.6 39 12 30 (PA port) Rc 1/8 2(A) NO 26.5 PA 35 43 3(R) 1(P) NC (R port) Rc 1/8,1/4 39.2 Switch mark (Mounting hole) 24.5 26.7 56.9 55.9 25 24 18.5 12 (P port) Rc 1/8,1/4 5-5-16 5 3 Port Air Operated Valve Series VPA300/500/700 Dimensions A B Body ported: VPA54231 83.9 26.1 Rc 1/8 3.5 NO NC (PA port) 32
Bit BYTE 64 (Maximum) Value The Bits 49 54 56 32 30 33 30 2D 49 4C 32 42 4E (hexadecimal number) indicate "ITV2030-IL2BN." (ASCII code) 20 - Setting using buttons ! Caution If the incorrect key is pressed or incorrect information is displayed during setting, power must be shut off and the procedure started again.
O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110 110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2 2 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 AMH150 1 8 1 4 3 8 166 187 187 218 218 241 241 277 334 24 27 27 32 32 37 37 39 55 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122
No.PF-OMJ0018-F PRODUCT NAME Digital Flow Switch (Remote type monitor unit) MODEL / Series / Product Number PFM3## Table of Contents Safety Instructions 2 Model Indication and How to Order 9 Summary of Product parts 12 Mounting and Installation 13 Installation 13 Wiring 15 Flow Setting 19 Function Setting 21 Default settings 21 F0 Selection of connected sensor Unit selection function 22
7.4.5 Composition of Required Message (from master to the product) . 7-10 7.4.6 Composition of Response Message (from the product to master) . 7-11 7.4.7 Explanation of Code . 7-12 7.4.8 Cautions for Communication . 7-14 7.4.9 Communication Example . 7-16 7.4.10 Connection (for RS-485) . 7-18 7.4.11 Identification Code List . 7-18 7.4.12 ASCII Code List . 7-18 7.5 Performance Chart . 7-19
Modify the mounting. 19 20 21 4. Construction Standard product: Double acting/single rod Table 12. Parts list No. Description Qty No.
21 12 1.6 15.5 100 50 12.4 12.5 60.6 75h9 77h9 35H9 13 26H9 12 5 3 7.5 20 10.5 18 10.5 (mm) JC JD JJ JU JV Q S SC SD SU UU WA WB WC WD WE WF XA XB XC YA YB YC Size 10 20 30 50 M8 x 1.25 12 M5 x 0.8 M4 x 0.5 M10 x 1 34 132.5 46 50 27.3 47 15 3H9 3.5 M5 x 0.8 8 32 27 3H9 3.5 19 3H9 3.5 M10 x 1.5 15 M6 x 1 M5 x 0.5 M12 x 1.25 37 168.5 58.5 63.5 39 54 20.5 4H9 4.5 M6 x 1 10 43 36 4H9 4.5 24
Refer to the above drawing for other dimensions. n L 1 38 28 2 57 47 3 76 66 4 95 85 5 114 104 6 133 123 7 152 142 8 171 161 9 190 180 10 209 199 11 228 218 12 247 237 13 266 256 14 285 275 15 304 294 16 323 313 17 342 332 18 361 351 19 380 370 20 399 389 L1 L2 4-5-9 10 Series VK300 Precautions Be sure to read before handling.
Cylinder Speed Chart Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VK VZ1120--M5 (Piping: 4 x 1 m) VZ VF AS1301F-M5-04/AN120M5 AS1301F-M5-04/AN120-M5 Speed controller/Silencer VFR
42.5 84 42.5 84 1/4 3/4, 1 28 27.8 43.5 176 46 3.3 M62 x 1.5 43.5 44.5 55 42.5 84 42.5 84 1/4 95 1 AR Optional specifications AL Bracket mount Panel mount Model M N Q R S T U V W Y Z AW AR10 AR20(K) AR25(K) AR30(K) AR40(K) AR40(K)-06 AR50(K) AR60(K) 4.5 6.5 30 25 28 40 2 18 18.5 44 5.4 15.4 34 30 55 2.3 25 28.5 14 6 AG 15.4 34 44 5.4 30 55 2.3 26 32.5 16 6 8 6.5 41 40 46 53 2.3 31 38.5 19
Applicable Model/Drain Capacity Model AF10 AF30 AF40 AF40-06 AF20 AF50 3/4, 1 AF60 Port size M5 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 1 Drain capacity (cm3) 88 9 19 43 Note) Please consult with SMC for dimensions. 30 AF X64 03 Long bowl Semi-standard: Select one each for a to d. Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order.
CN2 11 15 14 2 12 PF SG CR PP PG NP NG SD V24 SON LSN LSP ALM SG 3 12 13 9 10 7 8 20 17 11 LG 19 P5 4 OP 1 V+ 20 12 7 6 P5 LG MR MRR MD MDR SD SG 7 8 1 2 4 5 9 P5 LG MR MRR MD MDR SHD 7 8 1 2 4 9 P5 LG MR MRR MD MDR SHD Note 3) Detector 17 16 Plate 5 Note 2) Note 6) Be sure to connect the shielding wires to the ground plate inside the connector.