Applicable model 84 84 03 FGD-CV002-04 06 03 FGD-CV003-04 06 03 FGD-CV004-04 06 03 FGD-CV001-04 06 32 32 FGDT/F FGDT/F FGDC/E FGDC/E Note 1) Same as standard product except for cover assembly Note 2) 03, 04, and 06 indicate the relevant port sizes (Rc3/8, 1/2, 3/4).
Metric size Inch size P . 15-11-3 3.2 With One-touch fittings 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" Use 1/8" tube. 23 04 06 08 10 12 01 03 05 07 09 11 13 4 6 8 10 12 Flow Direction Symbols on Body JIS Symbol Symbol 15-9-10
How to Order With bumper Series RBQC Basic type Series RBQ C 20 07 RBQ RBQC C Replacement part no.
Inch size Metric size 01 02 23 2 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 03 05 07 09 11 13 Control type 04 06 08 10 12 0 1 Meter-out Meter-in Use 1/8" tube.
Metric thread (M3, M5) Unified thread (10-32 UNF) R NPT M3 x 0.5 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 ASN M5 Nil U10/32 01 02 03 04 AQ N ASV AK Needle Valve/Flow Characteristics Note) The flow characteristics are representative values.
Symbol Data type Data length Bit [byte] Description (IO-Link standard) U8 8 [1] UIntegerT Unsigned integer U16 16 [2] S16 IntegerT 16 [2] Signed integer F32 Float32T 32 [4] Floating point number C32 StringT 32 [4] String 3: "Y" indicates that the parameter setting data is saved to the master, and "N" indicates that the parameter is not saved. 4: Read/write to un-selectable items will be rejected
Thread type AS-D Port size Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT M5 U10/32 01 02 M5 x 0.8 AS-T 10-32 UNF 1/8 N ASP 1/4 ASN Made to Order AQ ASV Grease-free (Seal: Fluorine Coated) + Throttle Valve (Without Check Valve) X21 Lubricant: Vaseline X12 AK Ex.) AS1201FM-M5-23-X12 Ex.)
port With sub-plate M5 3 position closed center Symbol 5 port 4 port 3 position exhaust center 5 3 position pressure center 2 position single 2 position single (B)2 4(A) (B)2 4(A) 1 (P) 3(R) 1 (P) (R)3 5(R) How to Order Manifold Base 2 position double 2 position double 4(A) (B)2 4(A) (B)2 Same manifolds as SYJ3000 series are prepared. 5(R) 1 (P) (R)3 3(R) 1 (P) SS5YJA3 Fill the same as SS5YJ3
Symbol Data type Data length Bit [byte] Description (IO-Link standard) U8 8 [1] UIntegerT Unsigned integer U16 16 [2] S16 IntegerT 16 [2] Signed integer F32 Float32T 32 [4] Floating point number C32 StringT 32 [4] String 3: "Y" indicates that the parameter setting data is saved to the master, and "N" indicates that the parameter is not saved. 4: Read/write to un-selectable items will be rejected
(b00) Analog output setting*14 20mA Current output b00=inC b00=dEC 4mA 100% 0% 0% 100% Stroke Fig. 32 Setting for analog output will follow the position value (P value).
Metric size Inch size 3 4 5 6 1/8 standard 1/4 standard 3/8 standard 1/2 standard 07 09 11 13 06 08 10 12 1/4" 5/16" 3/8" 1/2" 6 8 10 12 Type Port size 3 Universal Symbol 01 02 03 04 F02 F03 F04 N01 N02 N03 N04 Pilot port M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 G 1/8 G 1/8 G 1/4 10-32 UNF NPT 1/8 NPT 1/8 NPT 1/4 Cylinder side R 1/8 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2
16.8 -06E 4.7 17 6 12.8 22.3 10.1 18.4 17 1/8 19 43.4 M16 x 1 20 -08E 18.5 8 30.2 15.7 6 22.6 22 24 46.4 M20 x 1 22 -10E 21 10 54.7 22.6 17 47 M14 x 1 16.8 KK4P-06E 4.7 17 6 12.8 30.6 10.1 17 19 50.2 M16 x 1 20 -08E 6.2 18.5 8 22.6 38.2 19.8 25.2 1/4 22 24 53.2 M20 x 1 22 -10E 7.7 21 10 35.3 61.4 27.6 54.2 -12E 9 75.2 40.2 24 27 M22 x 1 23 22 12 50.9 60.1 KK6P-12E 9.2 86.1 41.2 31 1/2 30 32
Symbol Color Color indication Symbol Tube size 0425 0604 0805 1065 1208 Symbol Color Color indication Symbol Tube size 01 05 07 11 13 4mm (5/32") 6mm 8mm (5/16") 10mm 12mm 1/8" 3/16" 1/4" 3/8" 1/2" See Color Chart Below. For Non-Quick Ship Colors add "U" to the end of the part number. See Color Chart Below.
Metric size 3.2 4 6 4 6 6 8 6 8 10 12 10 12 Inch size 1/8" 5/32" 1/4" 5/32" 1/4" 1/4" 5/16" 1/4" 5/16" 3/8" 3/8" 1/2" Flow Direction Symbol on Body C values: Sonic conductance dm3/(sbar) Free ow 0.3 0.4 0.6 0.4 0.6 1.0 1.2 1.1 1.6 2.2 2.6 2.4 3.5 Symbol Controlled ow 0.3 0.4 0.6 1.0 1.2 1.3 1.9 2.7 3.3 2.8 4.1 pressure ratio Free ow 0.3 0.2 0.3 0.1 0.2 0.2 0.3 0.2 b values: Critical Controlled
TMH M5 Port size ASD M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 Applicable tubing O.D. Note) Type 01 02 03 04 Inch size Metric size Elbow Universal 2 3 1/8" AS 23 01 3.2 03 05 07 09 11 13 04 06 08 10 12 4 5/32" 6 3/16" Control AS-FE U10/32 N01 N02 N03 N04 8 1/4" Meter-out Meter-in 0 1 10 5/16" Made to Order Refer to the below for details.
Inch size 1/8" 5/32" 1/4" 5/32" 1/4" 1/4" 5/16" 1/4" 5/16" 3/8" 3/8" 1/2" Flow Direction Symbol on Body Free flow 0.3 0.4 0.6 0.4 0.6 1.0 1.2 1.1 1.6 2.2 2.6 2.4 3.5 Controlled flow 0.3 0.4 0.6 1.0 1.2 1.3 1.9 2.7 3.3 2.8 4.1 C values: Sonic conductance dm3/(sbar) Symbol b values: Critical pressure ratio Free flow 0.3 0.2 0.3 0.1 0.2 0.2 0.3 0.2 Controlled flow 0.2 0.3 0.4 0.2 0.2 0.3 0.1
Note) Metric size 23 04 06 08 10 12 Inch size 3.2 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 4 6 8 10 12 Made to Order (For details, refer to page 622.)
. : Bit offset: 32 to 47 in the process data will change to 0 (Forcibly output OFF)/ 2000 (Forcibly output ON). Press the SET button to set.
16.8 -06E 4.7 17 6 12.8 22.3 10.1 18.4 17 1/8 19 43.4 M16 x 1 20 -08E 18.5 8 30.2 15.7 6 22.6 22 24 46.4 M20 x 1 22 -10E 21 10 54.7 22.6 17 47 M14 x 1 16.8 KK4P-06E 4.7 17 6 12.8 30.6 10.1 17 19 50.2 M16 x 1 20 -08E 6.2 18.5 8 22.6 38.2 19.8 25.2 1/4 22 24 53.2 M20 x 1 22 -10E 7.7 21 10 35.3 61.4 27.6 54.2 -12E 9 75.2 40.2 24 27 M22 x 1 23 22 12 50.9 60.1 KK6P-12E 9.2 86.1 41.2 31 1/2 30 32
Horizontal mounting Downward mounting 83 27 94 27 26 32 Center bracket/IZS31-BM Reduced-wiring Fieldbus System 40 15 23 14 3 5.4 18 24 39 Static Neutralization Equipment M5 screw for mounting 2 Ionizer 27 100 Alphabetical Index Length Measuring/ Counter Angle adjustable Ionizer full length (L) Note) Number of center brackets included in a model with brackets.