(50/60 Hz), 240 VAC (50/60 Hz) 12, 24 VDC?
(50/60 Hz), 240 VAC (50/60 Hz) 12, 24 VDC?
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: M (Applicable to Deionized Water Piping)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Model: 2 (SGC200), Valve Type: 1 (Normally Closed), Seal Material: B (FKM), Pressure Range: 10 (0 to 1 MPa), Thread: Rc, Port Size: 15 (1/2), Pilot Valve: Y (0.35 W Type, V116), Voltage: 3 (110 VAC (115 VAC) 50/60 Hz), Electrical Entry: DO (DIN Terminal Without Connector)
Cooling Capacity: 150, Thread Type: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: AK (A + K)
Body Size: 4000, Thread: N (NPT), Port Size: 04 (1/2), Option: S (Silencer), Voltage: 3 [110 VAC (115 VAC)], Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)
Cooling Capacity: 150, Thread Type: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 4 [220 VAC, (230 VAC)], Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: E (Push-turn Locking Type, Manual)
This model is compatible with single phase 100 VAC 50/60Hz power. Air cooled only, without heating feature ; Cooling capacities: 1.2 kW, 1.6 kW (at 60Hz) ; Temperature range setting: 10 to 30°C ; Temperature stability: ±2°C ; Power supply requirement: single phase 100 VAC, 50/60Hz ; Standards: RoHS ; Circulating fluid: Tap water or 15% ethylene glycol solution
This model is compatible with single phase 200 VAC 50/60Hz power. Air cooled only, without heating feature ; Cooling capacities: 1.2 kW, 1.6 kW, 2.2 kW (at 60Hz) ; Temperature range setting: 10 to 30°C ; Temperature stability: ±2°C ; Power supply requirement: single phase 200 VAC, 50/60Hz ; Standards: RoHS ; Circulating fluid: Tap water or 15% ethylene glycol solution
Cooling capacities: 10.5 kW, 15.7 kW, 20.5 kW, 25 kW, 28 Kw ; Temperature range setting: 5 to 35°C ; Temperature stability: ±0.1°C ; Power supply requirement: 3-phase 200 VAC, 50Hz or 3-phase 200 ~ 230 VAC, 60Hz ; Waterproof specification: IPX4 ; Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution
Cooling capacities: 11.5 kW, 15.7 kW, 20.6 kW, 24 kW ; Temperature range setting: 5 to 35°C ; Temperature stability: ±0.1°C ; Power supply requirement: 3-phase 200 VAC, 50Hz or 3-phase 200 ~ 230 VAC, 60Hz ; Waterproof specification: IPX4 ; Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution
Cooling capacities: 2 kW, 8 kW, 15 kW, 30 kW ; Temperature range setting: 20 to 90°C ; Temperature stability: ±0.3°C ; Power supply requirement: 3-phase 200 VAC / 50Hz or 3-phase 200~208 VAC / 60Hz ; Circulating fluid: Clear or deionized water, fluorinated liquid, or 60% ethylene glycol solution ; Standards: UL, CE, SEMI (S2-0703, S8-1103, F47-0200), SEMATECH (S2-93, S8-95)
Fluid fill and drain ports (800W, 1kW) on the front; Mechanical sealless magnet pump eliminates shaft seal leaks; Cooling/Heating capacities: 200W/600W, 400W/1kW, 510W/1.2kW, 800W/1.4kW, 1kW/2kW; Temperture stability: ±0.03°C or Better depending on load stability; Power supply requirement: 100 ~ 240 VAC (200-800W) or 200~240 VAC (1kW) (50/60Hz); Circulating Fluid: water or 20% ethylene glycol
Cooling capacities: 10 kW or 15 kW ; Temperature range setting: 5 to 35°C ; Temperture stability: ±1.0°C ; Power supply requirement: 3-phase 200 VAC 50 Hz or 200~230 VAC 60 Hz ; Waterproof specification: IPX4 ; Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution
This model is compatible with single phase 230 VAC 50/60Hz power. Air cooled only, without heating feature ; Temperature stability: ±2°C ; Power supply requirement: single phase 230 VAC, 50/60Hz ; Standards: RoHS ; Circulating fluid: Tap water or 15% ethylene glycol solution
Fluid fill and drain ports on the front; Mechanical sealless magnet pump eliminates shaft seal leaks; Cooling/Heating capacities: 800W/1.4kW, 1.2kW/2kW; Temperture stability: ±0.03°C or Better depending on load stability; Power supply requirement: 100 ~ 240 VAC (800W) or 200~240 VAC (1.2kW) (50/60Hz); Circulating Fluid: water or 20% ethylene glycol; Standards: CE, UL, RoHS
Flow ranges (lpm): 1-10, 10-20, 20-50; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4; Temperature rating (°C): -5 to 60; Operating pressure (MPa): 0.1 to 0.6; Withstand voltage: 1500 VAC (one minute)