In this case, the point is between the discharge curves (solid lines) for SUP=0.2MPa and SUP=0.3MPa, and based on the proportional relationship to these lines, the pilot air pressure for this point is approximately 0.25MPa. 40 20 1 0 2 3 4 5 6 7 Cycle (Hz) PA513 Air consumption 400 350 Air consumption l/min (ANR) SUP=0.5MPa Note 1) Even when switching cycles are changed for PA3000 with SUP
PF2A750,550 PF2A711,511 3.0 1.0 10 Pressure loss (kPa) Pressure loss (kPa) Pressure loss (kPa) 2.5 0.8 8 2.0 6 0.6 1.5 0.4 4 1.0 0.2 2 0.5 Flow rate (l/min) 0 100 10 25 50 75 5 2.5 7.5 0 5 10 15 20 25 30 40 35 45 50 0 1 10 Flow rate (l/min) Flow rate (l/min) PF2A721,521 PF2A751,551 50 20 40 Pressure loss (kPa) Pressure loss (kPa) 15 30 10 20 5 10 Flow rate (l/min) 0 200 0 50 100 150200250 300 400 350
Flow rate ( /min (ANR)) Relief flow rate ( /min (ANR)) Supply pressure P1 (MPa) IR1010-01 IR1010-01 IR1010-01 Supply pressure: 0.7 MPa Back pressure: 0.7 MPa 0.4 0.204 0.7 Set pressure P2 (MPa) 0.6 Set pressure (MPa) Set pressure (MPa) 0.202 0.3 0.5 Set point 0.4 0.200 0.2 0.3 0.198 0.2 0.1 0.1 0.196 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 1.0 0 40 80 120 160 200 0 50 100 150 200 250 300 350
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.2 50 100 150 200 250 300 350 400 0 Flow rate (l/min) ( ): Gas pipe bore sizes 16-12-10
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 50 20 40 Pressure loss (kPa) Pressure loss (kPa) 15 30 10 20 5 10 Flow rate (l/min) 0 200 0 50 100 150200250 300 400 350 450 500 20 50 100 150 Flow rate (l/min) Sensor Unit Construction PF2A710/750 PF2A510/550 Component Parts No. q w e r t Description
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500 700 900 10 500 700 900 10 700 1,000 Flow rate Q l/min (ANR) How to read
Air consumption (l/min (ANR)) 140 120 SUP = 0.5 MPa 100 SUP = 0.3 MPa 80 SUP = 0.2 MPa 60 40 20 1 0 2 3 4 5 6 7 Cycle (Hz) PA513 Air Consumption 400 Air consumption (l/min (ANR)) SUP = 0.5 MPa 350 300 Calculating Air Consumption (PA3000) 250 SUP = 0.3 MPa 200 Find the air consumption for operation with a 4 Hz switching cycle and pilot air pressure of 0.3 MPa from the air consumption graph
Terminal with indicator light: DL) M (Conduit terminal: T) K (DIN terminal: D) I (Grommet: G) J (Conduit: C) 4 x 2-18 mounting hole Applicable flange Pilot port Rc A B C D E F G H I J K L M Model VNB5-32F VNB6-40F VNB7-50F 1 8 1 4 1 4 130 150 180 210.5 226 250 135 140 155 134 146 162.5 20 24 24 100 105 120 36 42 54 12 12 14 244 259.5 283.5 256.5 272 296 300.5 316 340 303.5 319 343 310.5 326 350
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4 x 2-18 mouting hole Applicable flange Pilot port Rc A Model L K J H F E D C B VNC5-32F VNC6-40F VNC7-50F 1 8 1 4 1 4 32 40 50 278 293.5 317.5 310.5 326 350 12 12 14 36 42 54 100 105 120 20 24 24 134 146 162.5 135 140 155 210.5 226 250 130 150 180 Flange
Specifications Min. operating pressure differential (MPa) Flow characteristics Max. operating pressure differential (MPa) Ambient temperature (C) Fluid temperature (C)(1) Withstand pressure (MPa) Orifice size (mm) Port size Weight (g) Model Air operated valve Air Effective area (mm 2) Solenoid valve 5 to 60 VXF 2150 1.0 AC AC 530 10 to 60 VXF2150 VXFA2150 170 0.03 1.0 2.0 20 3 4 VXFA 2150 5 to 40 350
W R AT E A N D E F F E C T I V E S E C T I O N A L A R E A Model ASP330F ASP430F ASP530F ASP630F 1.5MPa (218 PSI) Proof Pressure Tube mm 6, 8 6 8 8 10 10 12 1MPa (145 PSI) Max Operating Pressure Outside inch 1/4 1/4 5/163/8 3/8 0.1MPa (14.5 PSI) Min Operating Pressure Diameter 5/16 5/16 1/2 50> of Operating Pressure Pilot Check Valve Actuation Pressure Flow Rate l/min Controlled 180 330 350
0 Hysteresis Within 0.5% (Full span) ZF Output pressure (kPa) Within 0.5% (Full span) Repeatability 20 Sensitivity Within 0.2% (Full span) ZP Within 0.12% (Full span)/C Temperature characteristics 3% (Full span) Accuracy Output pressure display 40 ZCU kPa Minimum display: 1 (5) Units Ambient and fluid temperature 0 to 50C (With no condensation) 60 AMJ Enclosure Equivalent to IP65 Weight 350
(the value under the prescribed conditions) 0.8 0.7 0.6 Subsonic Critical pressure 0.5 0.4 0.45 0.45 Sonic 0.4 0.4 0.35 0.35 0.3 0.3 0.3 0.25 0.2 0.25 0.2 0.2 0.15 0.15 0.1 0.05 0.1 0.1 0.05 S = 0.54 VDW101 10 60 50 40 30 20 10 20 VDW 1.6 S = 1.2 125 100 75 50 S = 3.2 VDW202.3 350 300 250 200 150 100 50 S = 5.8 VDW203.2 600 500 400 300 200 100 S = 2.8 VDW302 300 250 200 150 100 50 VDW303
Dimensions (mm) Equation L1=10.5n+14.5, L2=10.5n+25 n: Station (Max.16) n L 1 2 46 56.5 225 235.5 6 88 98.5 262.5 273 3 56.5 67 237.5 248 7 98.5 109 275 285.5 4 67 77.5 250 260.5 8 109 119.5 287.5 298 5 77.5 88 250 260.5 9 119.5 130 300 310.5 10 130 140.5 312.5 323 14 172 182.5 350 360.5 11 140.5 151 312.5 323 15 182.5 193 362.5 373 12 151 161.5 325 335.5 16 13 161.5 172 337.5 348 L1 L2 L3
Vertically facing downward Supply port: Front port Work mounting position: Fixed to the piston rod (Without the guide) Cylinder: CDG1G (20 to 100) -200K59S After preparatory operation P Graph A: Load weight range Graph B: Max. driving speed at manual operation 500 Piping length: 1m 1400 Load ratio 90% 450 450 Load ratio 50% 1300 Piping length: 5m Min. load weight 1200 400 Supply pressure: 1100 350
Silicon rubber Urethane rubber Fluoro rubber EPR 178 144 143 141 139 350 301 299 414 365 363 Add or deduct the weight shown in the table on the left for other materials. 71 38 37 83 50 49 149 115 114 112 110 40 50 63 80 100 125 1 1 2 3 5 8 0 0 0 1 1 3 5 8 16 27 53 84 1 0 0 1 1 0 How to Order A14 H N 40 ZPT Vacuum entry/Mounting thread diameter (Vacuum entry port) Pad diameter (mm) 40, 50
P S I : 0 . 1 N d r a ' . k P a : 1 Ambient and lluid temoeralure 0 to 50'C {with no condensation) Enclosure tP65 Hated pressure I Weight tw10trn ADorox. 250 a {without options) tw20t Aoorox. 350 q (without options) tws0 Aoprox. 645 q (without options) R = ='5 Note 1) Please refer to graph 1, relation lo lhe ditferences belween lhe sel pressure and input.
Both Ends Actuation D Double Acting S Spring Heturn T Spring Extend 9/t6" 056 3t4" 075 1-1l16' 106 t-1/2' 150 2" 200 2-1n' 250 3' 300 4" 400 o12 025 037 050 062 075 087 100 Solid State Switch Sboke 125 150 I -t,14" 1/8. 1t4" 3/8' 1f2" 5/8' 94" 1-1f2" I /4' 200 2-1n" 300 350 400 3-1t2" 4' The siandard lead wire length is 0-5m. 'L' is add6d lor 3m. long lead wire.
Stations Applicable blank plate ass'y vK300-42-1A Dimuuiun $uies t{U|ff30 Body Ported Grommet (G): NVKF332-"G-M5 inch (mm) Base Mounted Grommet (G) : NVKF334rG-01 T inch (mm) =1 1 .81 (=3001 lld wi'e hQt') Ssis ilUff300 Dimsui Body Ported (Top Ported) lType 20 Manifold NVV3KF3-20-Stations-007 inch(mm L: Dimensions 19 20 14.84 15.59 (377) 't3.78 r4.53115.28 (350) (36s) (388) ( 1 r 1 ) ( 1
N\rz3o4FoH 0.18(4.5)Dia L typ plug conneclorz/NVZ304-OL.Nvz384R-OL M type piug connector.,/Nvz3o4-OM Nvz3O4R-Oil Type 20 Manifold,z Top Ported inch (mm) Grommet(G),(H) L type plug connector (L) M type plug connector TApe 21R Manifold,/ Top Ported(External Pilot) inch(nn) Grommet (G), (H) L type dug connector(L) H type plug connector ( ) o = 6 o J 13.78 (350) r3.