Body Size: 4 (1/2), Valve Option: for General, Port Size: 04 [1/2 (15A)], Voltage: 6 (12VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: Z (Light/Surge Suppressor), Actuation Type: B (N.O., Normally Open), Pilot: Standard (Internal Pilot), Thread: T (NPTF)
Body Size: 8 (1 1/2), Valve Option: for General, Port Size: 20 [2 (50A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: Z (Light/Surge Suppressor), Actuation Type: A (N.C., Normally Closed), Pilot: Standard (Internal Pilot), Thread: T (NPTF)
Series: 542 (VP500), Pilot Type: Internal Pilot, Pressure Specification: K (High-pressure Type, 1.0MPa), Coil Specification: Standard, Voltage: 1 (100VAC, 50/60Hz), Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: T (NPTF), Actuation Type: A (N.C., Normally Closed)
Stations: 2 Stations, AB Port: 02L (1/4, Left), AB Thread: T (NPTF), Control: None, PR Port: 02B (1/4, Both Sides), PR Thread: T (NPTF), Silencer: SB (Silencer Box)
Stations: 2 Stations, AB Port: 02R (1/4, Right), AB Thread: T (NPTF), Control: None, PR Port: 02D (1/4, Bottom), PR Thread: T (NPTF)
Stations: 3 Stations, AB Port: 02R (1/4, Right), AB Thread: T (NPTF), Control: None, PR Port: 02D (1/4, Bottom), PR Thread: T (NPTF), Silencer: SB (Silencer Box), Voltage: 3 (24VDC)
Stations: 4 Stations, AB Port: 02R (1/4, Right), AB Thread: T (NPTF), Control: None, PR Port: 02D (1/4, Bottom), PR Thread: T (NPTF)
Stations: 1 Station, AB Port: 02R (1/4, Right), AB Thread: T (NPTF), Control: None, PR Port: 03B (3/8, Both Sides), PR Thread: T (NPTF)
Stations: 1 Station, AB Port: 03L (3/8, Left), AB Thread: T (NPTF), Control: None, PR Port: 02U (1/4, Top), PR Thread: T (NPTF), Silencer: SB (Silencer Box)
Stations: 2 Stations, AB Port: 02R (1/4, Right), AB Thread: T (NPTF), Control: E (Air Release Valve), PR Port: 03B (3/8, Both Sides), PR Thread: T (NPTF), Silencer: None, Voltage: 1 (100VAC, 50/60Hz)
Stations: 2 Stations, AB Port: 02Y (1/4, Bottom), AB Thread: T (NPTF), Control: None, PR Port: 02B (1/4, Both Sides), PR Thread: T (NPTF)
Stations: 2 Stations, AB Port: 02Y (1/4, Bottom), AB Thread: T (NPTF), Control: None, PR Port: 02U (1/4, Top), PR Thread: T (NPTF), Silencer: SB (Silencer Box)
Stations: 3 Stations, AB Port: 02L (1/4, Left), AB Thread: T (NPTF), Control: M (AirFilter w/Man.Drain, Reg., AirReleaseValve,Blank.Plate for Press.Sw.), PR Port: 02B (1/4, Both Sides), PR Thread: T (NPTF), Silencer: None, Voltage: 3 (24VDC)
Stations: 3 Stations, AB Port: 02L (1/4, Left), AB Thread: T (NPTF), Control: M (AirFilter w/Man.Drain, Reg., AirReleaseValve,Blank.Plate for Press.Sw.), PR Port: 02U (1/4, Top), PR Thread: T (NPTF), Silencer: SB (Silencer Box), Voltage: 3 (24VDC)
Stations: 2 Stations, AB Port: 02L (1/4, Left), AB Thread: T (NPTF), Control: None, PR Port: 02B (1/4, Both Sides), PR Thread: T (NPTF)
Stations: 8 Stations, AB Port: 02R (1/4, Right), AB Thread: T (NPTF), Control: None, PR Port: 02D (1/4, Bottom), PR Thread: T (NPTF)
Stations: 2 Stations, AB Port: 02R (1/4, Right), AB Thread: T (NPTF), Control: None, PR Port: 02B (1/4, Both Sides), PR Thread: T (NPTF)
Stations: 4 Stations, AB Port: 02R (1/4, Right), AB Thread: T (NPTF), Control: E (Air Release Valve), PR Port: 02D (1/4, Bottom), PR Thread: T (NPTF), Silencer: None, Voltage: 3 (24VDC)
Stations: 4 Stations, AB Port: 02R (1/4, Right), AB Thread: T (NPTF), Control: None, PR Port: 02B (1/4, Both Sides), PR Thread: T (NPTF)
Stations: 2 Stations, AB Port: 02R (1/4, Right), AB Thread: T (NPTF), Control: E (Air Release Valve), PR Port: 02B (1/4, Both Sides), PR Thread: T (NPTF), Silencer: None, Voltage: 3 (24VDC)