SMC Corporation of America
Elite Part Number Search
Search Results "ISE20-P-M5-LA2"

x 0.8 x 6 25, 32: M6 x 1 x 6 40: M8 x 1.25 x 8 Nickel plated 15 Hexagon socket head cap screw Carbon steel 20, 25: M5 x 0.8 x 6 32, 40: M6 x 1 x 8 16 Carbon steel Hexagon socket head set screw Nickel plated Replacement Parts/Seal Kit 17 Plate Bore size (mm) Kit no.

OLR CM OLP2 C11 FM PRS MOV P For Option M C11 FM PRS M For Option M P IDF55E-30 IDF75E-30 GFCI GFCI For Option R GFCI GFCI For Option R TB TB PRR PRR THR THR CM CM MC2 MC2 FM FM THP THS THP MC1 MC1 MC2 MC2 PRS1 PRS1 P P PRS2 THR PRR PRS2 THR PRR P P For Option M For Option M SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION CM Refrigerating Compressor PRR Phase Revarsal Relay OLR

Bore size (mm) Y NN P S X ZZ 20 M22 x 1.5 1/8 81 20 9 151 25 M24 x 1.5 1/8 81 20 9 156 32 M30 x 1.5 1/8 87 23 9 172 40 M33 x 2 1/4 108 25 11 198 49 Round Type Low Pressure Hydraulic Cylinder: 3.5MPa Series CHM Front flange type: CHMF Width across flats B2 Width across flats B1 N GA GB Rc P N Rc P 4-FD H1 H2 2-NN I IA D FY B MM Effective thread K F NB Width across flats NA NC FT A FX H S

Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m)

Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)

Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)

Output Specification: NPN Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: M5 Female Thread, Option 1: Lead Wire w/Connector, 2m, Option 2: -

Output Specification: NPN Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: M5 Female Thread, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter

proportional valve (VEP type) Current 5 (R1) 4 (A) 1(P) 2 (B) 3 (R2) IRV Simplifying circuit design Space-saving and piping work eliminated 2 (A) 1 (P) Selection of inlet pressure or atmosphere 3 (R) 5 (R1) 4 (A) VEX1 1(P) 2 (B) 3 (R2) SRH SRP SRF System Diagram ARX20 Power amplifier VEA25 VCHR Control circuit Voltage Current ITV 0 to 5 VDC 4 (A) IC 2 (B) PVQ Electro-pneumatic proportional

~30 Model D H K L M N P G F A B C E Q R Tolerance Tolerances (Depth) (Dimensions in Inches) 5/32 0.35 NCDRB1BW10 0.55 0.73 0.35 0.02 0.39 50 0.94 0.12 1.14 0.75 0.98 0 5-40 M5 (10-32NOM) -0.00015 -0.0014 (0.2) M3 -0.00045 3/16 0.47 NCDRB1BW15 0.71 0.73 0.39 0.02 0.59 50 1.14 0.16 1.34 0.94 0.98 0 5-40 M5 (10-32NOM) -0.01 -0.0017 (0.2) M3 -0.00017 15/64 9/16 NCDRB1BW20 0.79 0.98 0.39 0.02

L1 L3 L2 PE TB N PE L TB PRR ILS THR ILS MC THR MC MC PRR CM C01 MC OLR OLP1 CM OLP2 C11 FM PRS MOV P M C11 FM PRS M P IDF55E-30 IDF75E-30 GFCI R GFCI R GFCI GFCI TB TB PRR PRR THR THR CM CM MC2 MC2 FM FM THP THS THP MC1 MC1 MC2 MC2 PRS1 PRS1 P P PRS2 THR PRR PRS2 THR PRR P P M M CM PRS OLR FM PRS1 PRR MC PRS2 TB MC1 ILS GFCI MC2 THR MOV C01 CM THS OLP1 C11 FM THP OLP2

The test was performed in the axial and right angle directions of the main valve and armature for both energized an de-energized conditions. 1 (P) 5 (R1) 3 (R2) 3-position exhaust center (A) 4 (B) 2 Specific Product Precautions 1 (P) 5 (R1) 3 (R2) 3-position pressure center (A) 4 (B) 2 Caution Internal Wiring Specifications 1 (P) 5 (R1) 3 (R2) M8 Connector: Wiring specifications (EVS1-02)

VQZ300 Port size Symbol VQZ200 VZ 1 One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 10 M5 thread Rc (PT)1/4 C4 C6 C8 C10 M5 02 Metal seal Rubber seal 1 (P) 3 (R) VT (A) 2 N.O. 2 VT 1 (P) 3 (R) Note 1) Refer to p.2.10-18 for inch size Onetouch fittings. VP (A) 2 N.C. 3 VG 1 (P) 3 (R) Manual override (A) 2 N.O.

Turbine oil P-32 Nippon Mitsubishi Oil Corp. Turbine oil 32/Mitsubishi turbine 32 Cosmo Oil Co.,Ltd. Cosmo turbine 32 Japan Energy Corp. Kyodo turbine 32 Tightening torque Kygnus Oil Co. Turbine Oil 32 When installing fittings, etc., follow the procedures below. M5 M5 M5 M5 Kyushu Oil Co. Stork turbine 32 Showa Shell Sekiyu K.K. Turbine 32 1)When using SMCs fitting, etc.

Required screws are as follows: 2 x M5 (End plate: torque = 1.5 Nm) 2 x M5 (SI Unit: torque = 1.5 Nm) 4 x M (Valve manifold: refer to valve manifold catalogue) Fig. 3-1 Required screws Caution All manifolds are mounted using 8 screws (except VQC4000 which uses 7 screws). -13No.EX##-OMU0020-A 3.1.1. Valve manifold connection Connect the valve manifold with the 2 screws on the SI Unit.

(mounting hole) 4 x M5 (mounting hole) Position indicator LED M3 Ground terminal Position indicator LED LINK OUT GATEWAY UNIT EX500 SERIES IN EX500 SERIES GATEWAY UNIT (M12, 5 pins, socket) LAN PE PE PWR PWR LINK LINK SOL 100 L RUN OUT Power source connector Note 1) MS L ERR.

Connection thread: M5 First, tighten by hand, then use a wrench appropriate for the hexagon flats of the body to tighten an additional 1/6 to 1/4 turn. A reference value for the tightening torque is 1 to 1.5 Nm. Uni One-touch fittings cannot be used. Please use the fitting with a seal.

Applicable Model Model AR10 Port size M5 AR 10 X406 M5 A 0.4 MPa setting w q Option/Semi-standard: Select one each for a to f. Option/Semi-standard symbol: When more than one specification is required, indicate in alphabetic order.

Screw lightly the auto switch mounting screw (M5 x 0.8 x 16 L). 4. Set the whole body to the detecting position by sliding, tighten the mounting screw (M5 x 0.8 x 16 L) to secure the auto switch. (The tightening torque should be about 2 to 3 Nm.) 5. Modification of the detecting position should be made in the state of 3. Auto Switch Mounting Bracket Part No.

5 (R1) 3 (R2) Side-ported 1/8 (A) 4 (B) 2 Side-ported 1/4 FHG Number of solenoids 1 (P) 5 (R1) 3 (R2) Sealing type S D (A) 4 (B) 2 Single Nil R Metal seal Double FJG Rubber seal 1 (P) 5 (R1) 3 (R2) Rated coil voltage (A) 4 (B) 2 Option 3 4 24VDC FIG 12VDC Nil None 1 (P) 5 (R1) 3 (R2) Voltage other than above (50VDC or less) Indicator light with surge voltage suppressor 9 Z A02 VS1 01