The extemal pilot pressure is separate from the main supply pressure. wnh indicatq rightioc) Applications a Vacuum or low pressure (less than 10 PSI). Howewi this valve will not retain vacuum indefinitely a In case ot A port used in an open position. For example, air blorring. a In case ot P port extremely restricted.
(L) M typ plug connector (M)
(mm) +0.2 0.1 +0.2 0.1 1.6 0.1 0.1 Tolerance Basic diameter 1 0.5 1.5 0.8 0.8 1.2 0.5 Thickness (mm) 0.1 0.05 0.15 0.08 0.15 0.08 0.12 0.05 Tolerance 10 m 20 m 50 m Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bundle 100 m 50 Ft. (16 m) 100 Ft. (33 m) 2 m Straight
AW-A Optional specifications Model AR10-A AR20-A AR25-A AR30-A AR40-A AR40-06-A Bracket assembly Note 1) AR12P-270AS AR22P-270AS AR27P-270AS AR32P-270AS AR42P-270AS AR42P-270AS Set nut AR12P-260S AR22P-260S AR22P-260S AR32P-260S AR42P-260S AR42P-260S AC-B AF-A Note 2) Round type Standard G27-10-R1 G36-10-l01 G46-10-l01 0.02 to 0.2 MPa setting G27-10-R1 Note 3) G36-4-l01 G46-4-l01 Pressure
A G i 2 x P Port size G A 2 x P Port size b B Conduit DIN terminal D F Q S Cable 6 to 12 G1/2 F Q 280 D G1/2 45 (42) (44) 31.5 Built-in full-wave rectifier type R C C R E J J E 2 x M depth 5 H 2 x M depth 5 B B1 H G A G A B B1 2 x P Port size 2 x P Port size Bracket mounting hole a1 (VXS23, 25) a a1 (VXS24, 26) 6.5 10.5 Dimensions (mm) Model Port size P A B B1 C D E F G H J M Bracket mounting
DC24V10% DC24V 10% DC(+) DC(-) 8 / / 9 ( ) 10 , 5 m / / 11 1015 10 "-M" (kPaMPa) ( ) "M" 12 SI kPa,MPa 48 - No. 13 14 () 15 () / ( ) () 49 - 80mA 3.5 F.S.1 1F.S. 50 - 100.0-100.0 kPa 105.0-105.0 kPa 500 kPa 0.1 kPa DC24 V 10(p-p)10() 40 mA NPN PNP OUT1OUT2 80 mA DC26.4 V 2 V (80 mA ) 2.5 ms (20,100,500,1000,2000 ms ) 0.2F.S.1 digit 1 0 3 1/2 7 LED () 2% F.S
F A A Lr Lr = 150mm L X F 60 Table displacement (m) Table displacement (m) Table displacement (m) 10 40 LXFH-100 50 LXFH-100 8 LXFH-100 40 30 LXFH-75 LXFH-75 6 30 20 LXFH-50 LXFH-50 LXFH-75 4 20 LXFH-25 LXFH-25 10 LXFH-50 2 10 LXFH-25 0 Weight (kg) 0 Weight (kg) 0 Weight (kg) 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3 Displacement at the section indicated by the arrow when a load
Applicable air preparation equipment VHS20 VHS30 VHS40 VHS40-06 VHS50 Y200-A Y300-A Y400-A Y500-A Y600-A AC20-A AC25-A, AC30-A AC40-A AC40-06-A AC50, AC55 Note), AC60 Note) Y200T-A Y300T-A Y400T-A Y500T-A Y600T-A Note) VHS50 can be connected to AC55 and AC60.
model that can provide a gripping force of 10 to 20 times the workpiece weight, or more.
Option Applicable model 10-/21-AF20-A 10-/21-AF30-A 10-/21-AF40-A 10-/21-AF40-06-A 10-/21-AF50-A 10-/21-AF60-A Bracket assembly Note 2) AF52P-050AS AF22P-050AS AF32P-050AS AF42P-050AS AF42P-070AS Note 2) Assembly includes a bracket and 2 mounting screws. 1069-1 A Air Filter 1021-AF-A Dimensions AF20-A AF30-A to 40-06-A 10211021T N S J M U D J M U D S N T Air Preparation Equipment Pressure
Connector wiring diagram (mixed wiring) Connector type manifold 6 A 4 A 3 A 1 A 5 B 2 B Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing
~M~ / 6]X6' ~!gb ",*:z..-m;;:r~t 1~ 2M6 Screw depth 11 1 5 2-M6 Screw depth 11 ' ~ Lsii S ~ 60 L 4L.I Applicable clamp Part No. A cylinder , Maleual :Casl iron Malerial: Carbon steel I Matefial : Cast lIon . Part No.
24 VDC 10%, Ripple (P-P)10% or less 1 output: 17 mA or less at 24 VDC, 2 output: 25 mA or less at 24 VDC 5 ms or less 1% F .S. or less IP40 Operating: 0 to 60C, Stored: 10 to 60C (With no condensation) Operating/Stored: 35 to 85%RH (With no condensation) 10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s2 acceleration, in X, Y, Z directions for 2 hrs. each (De-energized) 980
Avoid to using 2 or more end lock cylinders at same time to perform a single task because binding may occur and one of the cylinders end lock may not release. y Use a speed controller as meter-out. Meter-in control may not allow lock to release. Locking style Turn 90 to counterclockwise pushing M/O button. Lock is released when G on cap and H OFF mark on M/O button correspond.
Axial Port (M3 Port) [M] MHZA2-6 M MHZAJ2-6 M S C S C M3 x 0.5 Piping port End boss assembly 20 -0.013 -0.035 4 5 8f8 33.8 12 10 23.7 Specifications and dimensions other than the above are the same as the basic type or the end boss dimensions of the MHZA type. Specifications and dimensions other than the above are the same as the basic type.
Connector wiring diagram (mixed wiring) Connector type manifold 6 A 4 A 3 A 1 A 5 B 2 B Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing
Consult with P/A in case of 10mm or less stroke. In general, mounting on a small-size actuator may cause hunting. For prevention, a pilot valve with a built-in output restriction is available. The restriction is removable.
0.56 0.66 0.70 B 0.56 0.66 0.70 A 1.50 1.81 2.29 A 1.50 1.81 2.29 B 0.48 0.58 0.61 B 0.48 0.58 0.61 A 1.42 1.72 2.21 A 1.42 1.72 2.21 B 0.60 0.70 0.74 B 0.60 0.70 0.74 A 1.54 1.85 2.33 A 1.54 1.85 2.33 B 0.37 0.46 0.50 B 0.37 0.46 0.50 A 1.30 1.61 2.10 A 1.30 1.61 2.10 Bore Bore 075 (3/4") 106 (1 1/16") 150 (1 1/2") 075 (3/4") 106 (1 1/16") 150 (1 1/2") Mounting Height (NCDM) (in) D-C7 D-C80
Dual rod cylinder 6, 10, 15, 20, 25, 32 Series CXS 10-/11-/1221-/22How to Order Clean series 10 11 12 CXSM,CXSL CXSM,CXSL CXSL Relief type Vacuum suction type Relief type (with specially treated sliding parts) Dual rod cylinder 10 CXS M 15 30 Y59A 21 CXS L 15 30 Y59A Number of auto switches Bearing type L M Ball bushing bearing Slide bearing Nil S n 2 pcs. 1 pc. n pcs.
Air suction filter 13-10-1 Series ZFA Using an ejector with a 2-stage nozzle, the ejector system can be used most efficiently. Air suction filter 13-10-4 Prevents problems related to vacuum circuits or airborne contaminants.