(mm) Bore size D-A9, D-A9V D-M9, D-M9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum Stroke for Auto Switch Mounting (2 pcs.)
(mm) Bore size D-A9, D-A9V D-M9, D-M9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum Stroke for Auto Switch Mounting (2 pcs.)
Note 2) Use standard power cables for 3 m and 10 m lengths.
Cooling Capacity HRSH100-A-20/40HRSH100-W-20/4014 16 Ambient temperature 32C Facility water temperature 32C 14 12 Cooling capacity [kW] Cooling capacity [kW] 10.5 10 11.5 12 10 Ambient temperature 43C 8 8 Facility water temperature 40C 6 6 Ambient temperature 45C 4 4 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSH150
0 90 Vacuum pressure reached 80 kPa Vacuum pressure in tank [kPa] 80 Vacuum pressure [kPa] 66 kPa 70 60 53 kPa 50 40 kPa 40 26 kPa 30 20 13 kPa 10 0 Suction flow rate [L/min (ANR)] 10 0 20 30 40 50 60 70 80 90 100 1 10 Time to reach vacuum [s] 1 0 2 3 4 5 6 7 8 9 10 11 12 Vacuum Break Flow Rate Characteristics*1 (Representative value) *1 Silencer exhaust specification The graph shows the
) IN OUT 01 ARJ 3 10 01 BG ARJ 3 10 F BG With One-touch fitting 04 01 Body size Option specifications 0.7MPa setting (standard) 0.2MPa setting With thread sealant Nil 1 S Model Relieving type 10 When set at 0.2MPa, a pressure gauge is not included.
L L D D Min. bore M L Model 10.4 3 31.6 4 KK3P-04L 5.3 7.2 16 3.7 18 10 12.8 4.5 32.8 6 -06L 11.4 8.0 17 10.1 20 18.4 1/8 15.2 34 8 -08L 16.8 9.7 18.5 15.0 12 23 6 18.5 36 10 -10L 18.5 23.0 21 18.0 17 26.5 12.8 4.5 40.2 6 KK4P-06L 11.4 19.6 17 10.1 20 14 15.2 6 41.4 8 -08L 19.8 21.3 18.5 17.5 23 25.2 1/4 18.5 7.5 42.8 10 -10L 27.5 25.7 21 24.7 26.5 17 44 -12L 29.6 28.0 29.0 20.9 9 12 22
Nylon tubing L L D D Min. bore M L Model 10.4 3 31.6 4 KK3P-04L 5.3 7.2 16 3.7 18 10 12.8 4.5 32.8 6 -06L 11.4 8.0 17 10.1 20 18.4 1/8 15.2 34 8 -08L 16.8 9.7 18.5 15.0 12 23 6 18.5 36 10 -10L 18.5 23.0 21 18.0 17 26.5 12.8 4.5 40.2 6 KK4P-06L 11.4 19.6 17 10.1 20 14 15.2 6 41.4 8 -08L 19.8 21.3 18.5 17.5 23 25.2 1/4 18.5 7.5 42.8 10 -10L 27.5 25.7 21 24.7 26.5 17 44 -12L 29.6 28.0 29.0
AS120M-M5 M5 x 0.8 9 9 8 10 28.2 24.8 10.3 29.8 33.2 AS120M-U10/32 10-32 UNF AS220M-01 12 R 1/8 Rc 1/8 14.3 14.6 18 31.4 27.4 14.1 32.4 36.4 AS220M-N01 NPT 1/8 12.7 AS220M-02 17 R 1/4 Rc 1/4 18 19.5 27.2 35.9 29.9 18 34.9 39.9 AS220M-N02 NPT 1/4 17.5 Dimensions of R and NPT threads after installation. 15-9-63
from the VY Valve. 02 14 2.0 3 03 38 3.3 body Ported Type 04 12 3.9 Terminal Designations are as follows: 04 12 7.2 5 06 34 8.9 1 = 24v Power Supply 2 = Control Signal 3 = Common Negative for both power and signal. 10 1 10 5% 2% + -2% 7 10 1 114 17 12 114 18 9 14 112 2 33 20 2 37 Courtesy of Steven Engineering, Inc. !
High pressure High vaccum Brown DC (+) Main circuit of switch Main circuit of switch Main circuit of switch Main circuit of switch SE1--14/-15/-18/-19 I Z Black OUT Set point ON Hysteresis LED Red Switches with variable hysteresis can be adjusted by means of the HYS potentiometer in the range 1 to 10% of the setting pressure range.
Electric actuators / Common precautions . 10 2.1 Wiring/Cables . 10 2.2 Design/Selection . 11 2.3 Mounting . 12 2.4 Handling . 13 2.5 Operating Environment . 15 2.6 Maintenance . 16 2.7 Actuator with Lock . 16 2.8 Design/Selection . 17 2.9 Handling . 17 2.10 Mounting . 18 2.11 Power Supply . 19 2.12 Grounding . 19 2.13 Wiring . 19 2.14 Maintenance . 20 3.
MHL2-10D MHL2-16D MHL2-16D MHL2-10D 2 1 2 1 60 60 25 25 0.6MPa 0.6MPa Holding force (N) Holding force (N) Holding force (N) Holding force (N) 50 50 20 20 0.5MPa 0.6MPa 0.5MPa 0.6MPa 40 40 15 15 0.4MPa 0.5MPa 0.4MPa 0.5MPa 0.4MPa 0.4MPa 30 30 10 10 0.3MPa 20 20 0.3MPa 0.3MPa 0.3MPa 0.2MPa 5 5 10 10 0.2MPa 0.2MPa 0.2MPa 10 20 30 40 50 60 70 20 40 60 80 100 120 20 40 60 80 100 120 0 0 0 10 20
6 148 137.5 123 12.5 7 160.5 150 133.5 13.5 8 173 162.5 144 14.5 9 185.5 175 154.5 15.5 10 198 187.5 165 16.5 3 135.5 125 102 17 4 148 137.5 112.5 18 5 148 137.5 123 12.5 6 160.5 150 133.5 13.5 7 173 162.5 144 14.5 8 185.5 175 154.5 15.5 9 198 187.5 165 16.5 10 210.5 200 175.5 17.5 L1 L2 L3 L4 L1 L2 L3 L4 31 Cassette Type Manifold Series SZ3000 Dimensions/SZ3000: Plug-in Stations SS5Z3-
655 K 18 K 75 K16K (17) 64 (K16K) 17) JIS 65A 10K JIS 65A 10K 40 51 1276 1418) (14~18) 1375 (1) () (1) 1,3 1,3 () 7122 20 350 700 752 (3) (2) (2) IDF100150F 6-3 6 3 IDX-OM-U021 6 IDF150F-30K16K (10,2m) () ) JIS 80A 10K ( (10 () () (K16K) JIS 80A 10K 2m) 0.7m) ( ( (10, 20 18 t 268 217 9351 t A A 8x23 8x19 75 20 4x A 1300 720 1290 160 150 t K K K16K 64 (K16K) (17)
2 x M5 x 0.8 (Vacuum port) 6.5 12 12 11 10 10 1 24 14 S O 20 46 24 30 K 15 (70) 10 24 24 12.5 4 12.5 4 10 30 When open F 17 17 54 4 x M6 x 1 through (Thread for mounting attachment) When open G (mm) J 32 68 88 H 176 276 316 G 138 238 278 F 98 158 178 E 38 80 100 D 87 129 149 B C 58 100 120 A MHL2-20D MHL2-20D1 MHL2-20D2 112211221122136 211 251 54 96 116 MHL2-25D 1122D A B C 12.5 +0.030 4H9
Slider type LEKFS series 2.1 Specification AC servo motorMotor typeS*/T*) Model LEKFS25 LEKFS32 LEKFS40 Stroke [mm] 100 to 500 100 to 500 200 to 600 Horizontal 10 20 20 30 40 45 30 50 60 Work load [kg] Note1) Vertical 4 8 15 5 10 20 7 15 30 Up to 400 1500 900 450 1500 1000 500 1500 1000 500 401 to 500 1200 720 360 1500 1000 500 1500 1000 500 501 to 600 900 540 270 1200 1000 500 1500 1000
Moreover, the residual voltage of the diode is approximately 1 V. 4-3-3 4 For details about certified products conforming to international standards, visit us at www.smcworld.com. 3 Port Direct Operated Solenoid Valve Rubber Seal Series SY100 Specifications Fluid Air 10 to 50C (No freezing. Refer to page 4-18-4.)
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Abnormal low tank fluid level 1 Low tank fluid level 2 None 3 None 4 None 5 Fan failure Alarm flag 1 6 None 7 None 8 Abnormal rise of circulating fluid temperature 9 Circulating fluid temperature rise 10 Circulating fluid temperature drop 11 TEMP READY
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 CH1 abnormal low tank fluid level 1 CH1 low tank fluid level 2 CH2 Abnormal low tank fluid level 3 CH2 low tank fluid level 4 Reservation 5 Fan failure Alarm flag 1 6 Reservation 7 Reservation 8 CH1 abnormal rise of circulating fluid temperature 9