x 0.8 depth 8 Stroke: S 2-M4 x 0.7 depth 6 11-/22-MXP16-20 Width across flats 8 Width across flats 3 A 4-M5 x 0.8 depth 7 (Plug: M-5P) 2-M5 x 0.8 Piping port H 17 M6 x 1 10.5 26.7 11 5 5.5 34 35 8.5 4-M6 x 1 +0.030 0 depth 4 4H9 depth 4 4H9 Prepared hole diameter 5.1 A 6.5 19 320.05 +0.030 0 30 0.50.05 W B D 2-M5 x 0.8 Piping port M5 x 0.8 Vacuum suction port 47 46 13 10.5 depth 2 4H9 J
A A Solid state auto switch D-M9B, D-M9N Reed auto switch D-A93 (mm) (mm) Stroke (mm) 20 41 29 47 35 Stroke (mm) 20 45 25 51 31 Auto switch operating range Auto switch operating range 15 40.5 20.5 Model Model 25 50.5 30.5 30 59 39 10 35 15 25 46.5 34.5 30 55 43 10 31 19 15 36.5 24.5 A B A B A B A B A B A B 11-/22-MXP10 11-/22-MXP10 11-/22-MXP12 11-/22-MXP12 3 5 11-/22-
Hs B A W 16, 20, 25 Approx. Hs W A A B CUJ CU 32 to 100 Approx.
Proper Mounting Position (Detection at Stroke End) and Mounting Height 32, 40, 50, 63 D-M9/D-M9W/D-A9 D-M9V/D-M9WV/D-A9V Hs B W A A A B (mm) D-A9V D-A9 D-M9 D-M9W D-M9V D-M9WV A B A B Bore size (mm) W Hs A B W A B Hs 32 40 50 63 12 [17] 9 1 12 [17] 9 29 8 [13] 5 3 (0.5) 8 [13] 5 27 16 11.5 1.5 16 11.5 32.5 12 7.5 5.5 (3) 12 7.5 30.5 14 <19> 14.5 4.5 14 <19> 14.5 42 10 <15> 10.5 8.5 (6)
Symbol X201 Machined Bleed Port M5 Thread 1 Regulator with a M5 thread machined on the relief port in order to connect it to the bleed port. X201 Standard model no. Machined bleed port M5 thread Dimensions Other dimensions are the same as the standard type.
Standard Base mounted Universal External pilot Flow Characteristics/Weight Flow characteristics (1) Port size Valve model Weight (kg) Series 2 1 (A P) 1 2 (P A) 3 2 (R A) 2 3 (A R) C [dm3/(sbar)] 3.3 4.0 2.9/2.9 3.1/2.9 6.6 9.1 6.5/7.0 7.9/8.1 12 15 12/12 15/14 Cv 0.86 0.99 0.74/0.76 0.79/0.83 1.6 2.4 1.7/1.8 1.8/1.9 2.9 3.8 2.9/3.1 3.5/3.3 C [dm3/(sbar)] 3.4 3.7 3.3/3.6 4.1/4.1
: mm Model A B C Fn Fd G J XLFV-16-2 40 108 38 30 17 41 XLFV-25-2 50 121 48 40 26 46 XLFV-40-2 65 171 66 55 41 54.5 XLFV-50-2 70 185 79 75 52 71 XLFV-63-2 88 212 100 87 95 70 80.5 XLFV-80-2 90 257 117 114 110 83 90.5 Model K L M N S T XLFV-16-2 17.2 10.2 3.6 3.6 M5 M5 XLFV-25-2 21.4 10.2 3.6 3.6 M5 M5 XLFV-40-2 33.9 10.2 3.6 3.6 M5 M5 XLFV-50-2 35.3 12 4 2 Rc1/8 M5 XLFV-63-2 43.8 12 4 2 Rc1
Left Right 15 -60 -60 10 -40 -40 Air consumption -20 -20 5 S 1 S 2 R U N L HL H S 1 S 2 R U N L HL H S 1 S 2 R U NL HL H S 1 S 2 R U NL HL H S 1 S 2 R U N L HL H S 1 S 2 R U N L HL H S 1 S 2 R U N L HL H S 1 S 2 R U N L HL H kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE
(mm) <M5> <M5> Weight (g) Applicable tubing KCH04-M5 KCH04-01S KCH06-M5 KCH06-01S KCH06-02S KCH08-01S KCH08-02S KCH08-03S KCH10-02S KCH10-03S KCH12-03S KCH12-04S 2.1 2.6 2.4 M5 x 0.8 9.8 30.8 26.1 32.4 37.4 28.9 42.4 45.7 34 50.5 51.5 54.2 41.6 27.3 22.1 28.9 33.4 22.9 38.4 39.7 27.5 44.5 45 47.7 33.6 18 2.1 2.6 2.4 4 8 1 8 10 11.8 12 14 M5 x 0.8 10 16 14 20 27 25 34 43 48 41 Reference dimensions
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Effective area (mm2) Weight (g) A L M Model
R E A C O D E A P P L I C A B L E T U B E OD Japan, Asia, Australia, UK N Canada, USA MM 23 3.2 04 4 06 6 08 8 10 10 12 12 Inch 01 1/8 03 5/32 05 3/16 07 1/4 09 5/16 11 3/8 13 1/2 B O D Y S I Z E 1 M5 2 1/8, 1/4 Standard 3 3/8 Standard 4 1/2 Standard T H R E A D P O R T S I Z E M5 ...M5 U01 ..1/8 U02 ..1/4 U03 ..3/8 U04 ..1/2 U32 ..10-32UNF 01 ... 1/8 02 ... 1/4 03 ... 3/8 04 ... 1/2 W I
Intermediate bracket A. Tap M5 thread on the brackets mounting positions at the installation side, and fix the ionizer body and brackets with M5 threads. M5 tap M5 threads 4. Adjust angle of the ionizer body to ensure proper static charge elimination, and fix it with detent threads (M5) of brackets.
Dimensions (mm) 1in = 25.4mm MSUA7 MSUA7-S, SE Scale: 60% Top ports/MSUA7-SE C 8-M4 x 0.7 depth 8 A port B port 67 13 2-M5 x 0.8 14 B 41 50 33 37 4-M5 x 0.8 depth 7 22.5 5 +0.025 0 3H9 A Long groove depth 5 (positioning pin hole) 22.5 47h9 0 0.062 +0.052 0 26H9 36 +0.030 0 3-4H9 depth 4 ( A , B , C ) 4 3 2-5.5 through 3-R2 3-R2 4.5 19 10.5 13 48h9 0 0.062 36 7 6 22.3 10.5 44 3 11 10 58.5
Grommet type 16.5 3 7 15 21 2-3.4 mounting hole Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 150 (Lead wire AWG#26) 22 5 6 22 20.5 3 2 11 1 7 6 5 12 12.3 12 25 M5 x 0.8 3 (EXH) port M5 x 0.8 2 (OUT) port M5 x 0.8 1 (SUP) port S070B-C-M5 Plug lead type 0.1 W with
Easy and simple wiring Connector type 16-6-7 2 Series ZSE2/ISE2 How to Order Operating pressure range/ Setting pressure range Piping specifications Single mounting R 1/8, M5 x 0.8 01 T1 Single mounting NPTF 1/8, M5 x 0.8 Nil L 0 to 1 MPa 0 to 100 kPa Note) M5 x 0.8 (female) thread.