temperature Cv 3) 0.7 1.3 1.0 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 4) 4 x 10-9 Pam3/sec 4) Ra max 15 in. (0.4 m) Option: 10 in. (0.25 m) Face seal , Tube weld Bottom mount 0.36 in3 (6.0 cm3) 1.27 kg 5) Inboard leakage Outboard leakage Leak rate Across the seat leak Surface finish Connections Installation Internal volume Weight 1/4 turn round knob with open/close indication window 7) 1/4
Power supply A Air-cooled refrigeration Symbol Power supply 10 Single-phase 100 VAC (50/60 Hz) Specications * There are different values from standard specications.
type allows element replacement ZFB30 8, 10, 3/8" 75 Easily replaced filter element ZFB40 1/2" 100 ZFC 10 4, 5/32" ZFA ZFA IN/OUT straight piping ZFC5 In-line type 20 Easy installation and removal with One-touch fittings ZFB ZFB 6, 1/4" 30 ZFC ZFC 5 P.281 Light and compact molded resin parts 8, 5/16" 70 ZFC7 10, 3/8" 80 Easily replaced filter element 12 100 Note) Flow rate when initial
Dynamic viscosity [m2/s] Viscosity [Pas] Density [kg/m3] Formulas below can be used for common units 1cP = 1mPas = 10-3Pas 1cSt = 1mm2/s = 10-6m2/s 13 Working Principle 1. When air is supplied, it passes through the switching valve and enters drive chamber B. 2.
Dynamic viscosity [m2/s] Viscosity [Pas] Density [kg/m3] Formulas below can be used for common units 1cP = 1mPas = 10-3Pas 1cSt = 1mm2/s = 10-6m2/s Pulsation Attenuating Capacity The process pump generates pulsation because it discharges a liquid using two diaphragms.
Install it above 0.6m from the floor. 9 Maintenance 10 Troubleshooting 6 Operation Continued 6 Operation Continued 9.1 Daily Check 10.1 Alarm list No. Modes Function Selectable Setting Default No.
Node address setting, Communication speed setting 1) Turn on (SW mode) the switch No. 10 of the 10-digit switch mounted on the SI unit. 2) Change the instance attribute value via the network as indicated below.
(Element life check) Max. contact capacity: 10 VA AC, 10 W DC Rated contact voltage (max. operating current): 125 V AC (0.08 A), 30 V DC (0.33 A) Max. contact capacity: 10 W DC Rated contact voltage (max. operating current): 30 V DC (0.33 A) Pressure drop 0.1 MPa Symbol V: Degreasing wash, white vaseline Reed switch Reed switch Body/housing is degreasing washed.
External pilot air LVC Lubrication Temperature Not required (Use turbine oil Class 1 ISO VG32, if lubricated.) 5 to 60C LVA No freezing LVH LVD Graph (1) VND 02 D Pilot Pressure (N.O. type) JIS Symbol Valve type Valve size N.C. N.O. Normally closed Normally open LVQ 0.7 12 (P1) 10 (P2) Pilot pressure should be within the range of A against the operating pressure.
For Flow Control Equipment Precautions, refer to Handling Precautions for SMC Products and the Operation Manual on the SMC website, http://www.smcworld.com Tubing O.D. 6, 8, 10 6 8, 10 8 10, 12 10 12 C values: Sonic conductance dm3/(sbar) Free ow 0.6 1.1 1.2 1.6 2.2 4.2 4.4 Controlled ow 0.7 1.1 1.3 2.2 2.6 4.4 4.8 Free ow 0.2 0.3 0.3 0.2 0.2 0.3 0.3 b values: Critical pressure ratio Controlled
to 60 psig (0.014 to 0.4 MPa) 5 to 100 psig (0.034 to 0.7 MPa) 15 to 200 psig (0.1 to 1.4 MPa) 15 to 300 psig (0.1 to 2.1 MPa) Code Bonnet Standard Panel installation 3) Code 01 02 06 10 20 30 No code P Connections (Inletq, Outletw) 3) Panel mounting hole: dia. 1.42 inch (36.1 mm).
Fittings & Tubing Air Cylinders Rotary Actuators -ARP20/ARP20K 10 21 -ARP30/ARP30K 10 21 -ARP40/ARP40K 10 21 Clean room compliant, copper-free, fluorine-free, silicone-free Air Preparation Equipment Clean room compliant Description Symbol Body size Body size 30 20 40 20 40 30 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting 0.008 to 0.6 MPa setting
Fittings & Tubing Air Cylinders Rotary Actuators -ARP20/ARP20K 10 21 -ARP30/ARP30K 10 21 -ARP40/ARP40K 10 21 Clean room compliant, copper-free, fluorine-free, silicone-free Air Preparation Equipment Clean room compliant Description Symbol Body size Body size 30 20 40 20 40 30 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting 0.008 to 0.6 MPa setting
M M5 M5 x 0.8 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection H/DL L/LL KC Applicable tubing O.D. Same dia. tubing 4 6 8 10 12 04 06 08 10 12 4 6 8 10 12 KK Tubing (rod) connection Different dia. tubing (plug-in reducer) KK130 DM Construction KDM KB KR KA KQG2 KG KFG2 MS KKA M5 type Male connector KP KP Description Material Component Parts LQ No.
Series VXP 1 2 3 10 N.C.
11 2 3 6 8 C R 3W Z Applicable model AL30 to 60 AL30 to 60 AL30 to 60 AL10 to 60 AL10 to 60 AL10 to 60 AL30 to 60 AL20 AL10 to 60 AL30 to 60 AL10 to 60 Body size F.R.L. 10 20 30 40 50 60 AV Thread type Metric thread (M5) Rc NPT G AU Nil AF N F AL20 Port size AR Body size Symbol Port size M5 1/8 1/4 3/8 1/2 3/4 1 10 20 30 40 50 60 (2) IR M5 01 02 03 04 06 10 Accessory When more than one
Cautions 10 7. Maintenance 11 8.
-) 10-ARP20(K) 10-ARP30(K) 10-ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G49-4-l01 G49-4-l02 0.4 MPa G49-2-l01 G49-2-l02 0.2 MPa Round type Note 2) G49-7-l01 G49-7-l02 0.7 MPa Pressure gauge ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] NPN output / Wiring bottom entry ISE35-R-25-MLA [ISE35-R-25-M (Switch body
Ratio of discharge amount to fresh water (%) 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity (mPa s) mPas Silicone oil Lubricant Vegetable oil Water 60 to 80 1 6080 340 950 1500 3150 9800 Viscosity (mPa s) cp 0 100 1000 10 150 | 2650 45 | 2 3000 4500 Tomato juice Honey Medical barium Wooster source Cutting oil 4500 45 2000 to 3000 8 - 8.
Temperature Alarm Common 10 10m 02 2m 04 4m 06 6m N AC100V L AC100V 6-8 PT-RTD 5 Unused 9 Unused RS-485 Communication connector Note: Always use shielded cable connected to this connector. 6-9 Unused 3-4 Unused 3-5 Unused 1-3 Unused 12-14 Unused 1 BUS + 2 BUS 5 SG 4 FG 15 FG Power supply connector (IEC60320,C14) E PE HEA100 1 2 Specifications Continued 2.4 Connector Specifications Power