Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
This is a legacy product, and replaced byAF20-N02-6CZ-D AF MASS PRO. FILTER, MODULAR. AIRLINE EQUIPMENT. AF MASS PRO 1/4 MODULAR (NPT). .34447 lb. DC.
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y (w/o
This is a legacy product, and replaced byISE20C-Y-P-N02-W-X500 ISE40/50/60 PRESSURE SWITCH. SWITCH ASSEMBLY. INSTRUMENTATION. ISE40/50/60 1/4 NPT VERSION. .34295 lb. DB.
This is a legacy product, and replaced byVHS20-N02-S-KZ-D VHS HAND VALVE. SINGLE ACTION RELIEF VALVE. VALVE. VHS BODY PT 1/4NPT (F). 0.15652 lb. EA.
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
FILTER ELEMENT (AFW20-N02-*). AIRLINE EQUIPMENT. AFW NO SIZE RATING. 21.
This is a legacy product, and replaced byAS3211F-N02-11S
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Body Option: 1 (External Pilot), Port Size: N02 (NPT1/4), Style: 06 (Roller Plunger), Suffix: S (Roller Material Hard Steel)
This is a legacy product, and replaced byVFM250-N02-01 VALVE, MECH L (NYLON). VALVE. VM BODY PT 1/4. .68200 lb.
Main Body Shape: Pipe Type, Additional Function: -, Ultimate Vacuum(kPa): -48, Air Consumption Flow Rate(l/min): 84, Vacuum Port Connecting Port Shape: [Others] NPT1/4, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: 1/8-27 NPT, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating Temperature Range(°C
Main Body Shape: Pipe Type, Additional Function: -, Ultimate Vacuum(kPa): -90, Air Consumption Flow Rate(l/min): 84, Vacuum Port Connecting Port Shape: [Others] NPT1/4, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: 1/8-27 NPT, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating Temperature Range(°C
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, CX, IF/PFA 1/8 INCH ALL OTHERS, 1.06556 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeProof pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, CB, IF/PFA 1/8 INCH NPT VERSION, .77161 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeProof pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, CA, IF/PFA 1/8 INCH PT VERSION, .86036 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeProof pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, CA, IF/PFA 1/8 INCH PT VERSION, .82369 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeProof pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput
SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated
SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated