SMC Corporation of America
Elite Part Number Search
Search Results "PF2A510-N02"

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]

Body Option: 1 (External Pilot), Port Size: N02 (NPT1/4), Style: 06 (Roller Plunger), Suffix: S (Roller Material Hard Steel)

This is a legacy product, and replaced byVM220-N02-30GA VALVE, MECH L 1/4 NPT (GREEN). VALVE. VM BODY PT 1/4NPT (F). .41800 lb.

Body Option: 0 (Internal Pilot), Port Size: N02 (NPT1/4), Style: 34 [Twist Selector (2 Position)], Suffix: R (Push Button Selector Color Red), Accessory: F [Foot Bracket (Internal Pilot Type Only)

Body Option: 0 (Internal Pilot), Port Size: N02 (NPT1/4), Style: 30 [Push Button (Mushroom)], Suffix: R (Push Button Selector Color Red), Accessory: F [Foot Bracket (Internal Pilot Type Only)]

This is a legacy product, and replaced byVHS20-N02-MZ-D VHS HAND VALVE. SINGLE ACTION RELIEF VALVE. VALVE. VHS BODY PT 1/4NPT (F). .44071 lb. EA.

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Pressure Range: ISE75G (0 to 2 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)

Main Body Shape: Pipe Type, Additional Function: -, Ultimate Vacuum(kPa): -48, Air Consumption Flow Rate(l/min): 84, Vacuum Port Connecting Port Shape: [Others] NPT1/4, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: 1/8-27 NPT, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating Temperature Range(°C

Main Body Shape: Pipe Type, Additional Function: -, Ultimate Vacuum(kPa): -90, Air Consumption Flow Rate(l/min): 84, Vacuum Port Connecting Port Shape: [Others] NPT1/4, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: 1/8-27 NPT, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating Temperature Range(°C

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, DX, IF/PFA 1/4 INCH ALL OTHERS, .45320 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeProof pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, CB, IF/PFA 1/8 INCH NPT VERSION, .59070 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeProof pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, CA, IF/PFA 1/8 INCH PT VERSION, .91950 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeProof pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, CX, IF/PFA 1/8 INCH ALL OTHERS, .88184 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeProof pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput

SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, DA, IF/PFA 1/4 INCH PT VERSION, .87062 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeProof pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, DA, IF/PFA 1/4 INCH PT VERSION, .59840 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeProof pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput