SMC Corporation of America
Elite Part Number Search
Search Results "ISE71-N02-L2-S"

Socket/Plug: L (Semi-standard Socket), Thread Port Size: N02 (NPT 1/4), Barb Fitting Port Size: Not Applicable, Nut Fitting Port Size: Not Applicable, One-touch Fitting Port Size: Not Applicable, Connection Type: F (Female Thread)

Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: N02 [NPT 1/4 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

M5 Port size With One-touch fitting M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32UNF NPT1/8 NPT1/4 NPT3/8 NPT1/2 01 02 03 04 U10/32 N01 N02 N03 N04 SMC Pneumatics, Inc. 5 Series ASIII1F-T Dimensions (mm) 1in=25.4mm L5 D3 Elbow type H (width across flats) Applicable tubing O.D. d A L4 D1 L3 M1 D2 T L1 L2 Metric sizes Inch sizes d T H D1 D2 D3 L1 L2 L3 L4 L5 A M1 Model A D1 Model T H D2 D3 L1 L2 L3

CONTROLLER, ACTUATOR, ELECTRIC ACTUATOR, L2, 32MM LE ELECTRIC ACTUATOR, 1.54323 lb

4 24 17 28.6 70.3 61.8 ASP630F-04-12S-X369 12 21.7 35.2 49.5 25 21.8 ASP330F-N01-07S-X369 NPT1/8 10-32UNF 12 8 14.2 23.9 31 13.6 38.6 35.2 16.8 1/4 13.2 ASP430F-N02-07S-X369 25.2 34.4 18.3 16.8 ASP430F-N02-09S-X369 5/16 15.2 27.2 36.4 18.4 18.7 17.46 12.7 18.5 48.7 42.4 NPT1/4 ASP430F-N02-11S-X369 3/8 18.5 35.3 44.5 19 20.8 NPT1/8 ASP530F-N03-09S-X369 5/16 15.2 29.7 41.2 18.7 NPT3/8 19 12

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None)

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None)

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 4, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: L2 (w/Control Unit, Supply Port: Left Side, With regulator, Square embedded type pressure gauge

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L2 (w/Control Unit

Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: L2

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L2 (w/Control Unit, Supply

Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: w/Unit Conversion Function, Stations: 6, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: L2

Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 6, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: L2

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L2 (w/Control Unit

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L2 (w/Control Unit, Supply Port:

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L2 (w/Control Unit, Supply Port: Left Side, With regulator, Square embedded type pressure gauge)