SMC Corporation of America
Elite Part Number Search
Search Results "CDUJB8-4D-F8PSAPCS"

Pilot: Internal Pilot, Voltage: 4 (220VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (1), Thread: F (G), Passage: A (Normally Closed), Option: Standard, CE Compliant: Q (CE Compliant)

Pilot: R (External Pilot), Voltage: 4 (220VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (1), Thread: F (G), Passage: External Pilot (N.O/N.C), Option: Standard, CE Compliant: Q (CE Compliant)

Pilot: Internal Pilot, Voltage: 4 (220VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 06 (3/4), Thread: F (G), Passage: A (Normally Closed), Option: Standard, CE Compliant: Q (CE Compliant)

Pilot: R (External Pilot), Voltage: 4 (220VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 04 (1/2), Thread: Rc, Passage: External Pilot (N.O/N.C), Option: Standard, CE Compliant: Q (CE Compliant)

Pilot: Internal Pilot, Voltage: 4 (220VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 04 (1/2), Thread: F (G), Passage: A (Normally Closed), Option: Standard, CE Compliant: Q (CE Compliant)

Pilot: Internal Pilot, Voltage: 4 (220VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 06 (3/4), Thread: Rc, Passage: A (Normally Closed), Option: Standard, CE Compliant: Q (CE Compliant)

Function: 2 Position Single, Body Option: Body Ported/Individual Pilot EXH, Pilot: Internal Pilot, Voltage: 220VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: Sub-plate Plug-in Terminal 1/8, Non Plug-in Std 1/8, Option: Foot Bracket

Function: 2 Position Single, Body Option: Body Ported/Individual Pilot EXH, Pilot: Internal Pilot, Voltage: 220VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: Sub-plate Plug-in Terminal 1/4, Non Plug-in Std 1/4, Option: Foot Bracket

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 4, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet,

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 4, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet,

Regulator Unit Combination: [Other FRL Combination Devices] Soft Start Up Valve, Port Size: NPT1/4, Filter Rating: 5μm, Compressed Air Quality: General Dry Air, Maximum Operating Pressure(MPa): 1, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure

Regulator Unit Combination: [Other FRL Combination Devices] Soft Start Up Valve, Port Size: NPT1/4, Filter Rating: 5μm, Compressed Air Quality: General Dry Air, Maximum Operating Pressure(MPa): 1, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Reverse Flow (Right to Left)] Right to left, Drain Cock: [Not Provided] No, Pressure Gauge

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 4, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet,

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 4, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet,

The CUJ miniature free mount series is a space saving compact cylinder. It is available in 4mm to 10mm bore sizes with stroke lengths up to 20mm for double acting and 10mm for single acting. Options include auto switch capabilities, double and single acting, mounting from 4 directions.Miniature free mount , Space saving compact cylinder , Available in 4mm to 10mm bore size, Cyl, Free Mount

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com