AR425 to 935 ARX AMR Winding direction ARM Sealant tape Expose approx. 2 threads ARP Recommended Proper Torque [Nm] Connection thread 1/8 1/4 3/8 1/2 Note) IR-A IR-A Torque 7 to 9 12 to 14 22 to 24 28 to 30 Note) Tightening force for connecting to the EXH port of IR32m1 2 -A is 8 to 10 Nm. Operating Environment IR Warning IRV 1.
-: Lithium soap based grease Grease 12-: Class 4, 21-: Class 5 Cleanliness class (ISO class) 11-/22-: Class 3 The maximum piston speed shown in the table above applies to the extension side.
Connections NPT 1/4 inch 1/4 inch compression Code 4 4T Seat material Code Material Viton (Standard) PTFE Kalrez Material No code TF KZ Body Brass Nozzle Diaphragm Code B S SH Gauge port (Inlete, r) 316 SS 316 SS Pressure gauge 1) 316 SS Hastelloy C-22 Hastelloy C-22 Code psig/bar unit MPa unit Pressure gauge unit 2) No gauge port No code Ports Unit psig/bar MPa Code No pressure gauge (Connections
Symbol Symbol Applicable tubing size (mm) 4 x 3 3 x 2 6 x 4 4 x 3 3 x 2 6 x 4 4 x 3 3 x 2 10 x 8 8 x 6 6 x 4 10 x 8 8 x 6 6 x 4 4 x 3 3 x 2 10 x 8 8 x 6 12 x 10 10 x 8 12 x 10 10 x 8 8 x 6 6 x 4 3 x 2 12 x 10 19 x 16 12 x 10 19 x 16 12 x 10 10 x 8 6 x 4 19 x 16 19 x 16 25 x 22 19 x 16 25 x 22 19 x 16 12 x 10 25 x 22 Applicable tubing size (inch) 1/8" x 0.086" 1/4" x 5/32" 3/16" x 1/8" 1/8
Suffix Basic size Description Symbol Nil Symbol Applicable air compressor T With terminal (Provided as standard for HAA37.) 7 15 22 37 7.5 KW 15 KW 22 KW 37 KW Caution on Design Caution Accessory (Option) 1. Do not to obstruct the aftercooler's vent inlet and outlet, and install the equipment more than 20 cm away from the walls or other equipment. 2.
Recommended proper torque Nm Connection threads 1/2 M5 1/8 1/4 3/8 3/4 1 28 to 30 1.5 to 2 7 to 9 12 to 14 22 to 24 28 to 30 36 to 38 Torque 2. Twisting moment or bending moment other than the dead weight of the equipment should not be applied. To avoid damage, external piping should be supported separately from the product. 3.
9.2 8 4 M8 x 1 M6 x 1 M5 x 0.8 SNJ-006A 9.2 8 3 SNJ-010A 3 12 13.9 SNJ-015A 16.2 14 3 M10 x 1 M14 x 1 SN-015A 21.9 19 5 Pad diameter: 10 to 50 ZP10B to 50B Model Size B06 A 6 ZP06B B 7 C 2.5 D 7 E F 13 G 3.3 H 9.1 Y 4 B08 8 ZP08B 9 2.5 7 13 4.7 10.1 4 B10 10 ZP10B 12 4 13 11.7 16 5.5 13.8 5.5 B13 13 ZP13B 15 4 13 14.2 18.5 8.7 19 7.5 B16 16 ZP16B 18 4 13 15.7 20 9.9 21 8.5 B20 20 ZP20B 22
H 25 3H9 depth 3 +0.025 0 4 3H9 depth 3 +0.025 0 (mm) N H I J M Z ZZ Model MXF12-20 4 22 11 36 65 65 76 MXF12-30 4 30 12 45 75 75 86 MXF12-50 6 65 13 80 111 111 122 142 Low Profile Slide Table Series MXF Dimensions: MXF16 Stroke adjuster at retraction end Stroke adjuster at extension end Width across hexagon socket hole 3 Width across flats 8 MXH N 2 ( 1) x 35 24 MXU Note) Blanking plug
(When ordering only bracket, refer to page 22.) With one bracket for mounting a single unit (Mounting screw is attached.) 12 C B 15 F Use for pilot pressure exhaust piping (Standard pump system is released to the atmosphere.)
PAO /PAO 17 18 Phase-A signal Encoder output pulse signals for two-phase pulse train with PBO /PBO Phase-B signal 90 phase differential 19 20 PCO /PCO 21 22 Phase-Z signal Origin pulse output signal Signal ground Connects to the 0 V pin on the control circuit of the PC or PLC ... etc.
No.LEC-OM08004 (ACT Controller) / LEC-W Series 1.3 2.5 3.6 3.1 .6 3.2 .8 4.10 4.1 .10 4.2 .13 4.3 .14 4.3.1 .14 4.3.2 .14 4.3.3 .14 4.4 .15 4.5 .15 4.6 .16 4.7 .16 5.17 5.1 .17 5.2 .20 5.3 .22 5.3.1 .22 5.3.2 .24 5.3.3 .25 5.3.4 .26 5.3.5 .27 5.3.6 .28 5.4 .29 5.4.1 .29 5.4.2 .29 5.4.3.29 5.5 .30 2 - ACT Controller/ 1.
Ground effect is not adequate by soldering the shield wire with wire rod to install the cable (Fig.2-3). 12.European Contact List (44) 1908-56 38 88 Hungary (36) 1-371 1343 Turkey (90) 212 221 15 12 Finland (358) 9-859 580 Portugal (351) 22 610 89 22 No.LC-OM08901 A (3/3) Denmark (45) 70 25 29 00 Poland (48) 22-548 50 85 Greece (30) 1-342 60 76 Switzerland (41) 52-396 31 31 France (33) 1-
Refer to Manifold option on page 22. Note2) When increasing over 4, 8, 12 manifold stations, exchange the Control Unit, Tension bolts, Protection plate and DIN rail for suitable parts for manifold stations. Refer to Replacement Parts on page 21. -23No. ZKJ-OM00201-D 8. Maintenance 8.1.
Function selection mode 22 Default setting 22 F0 Unit selection function 24 F1 OUT1 25 F2 OUT2 27 F3 Response time 29 F4 Auto-preset 30 F6 Fine adjustment of display value 32 F11 Display resolution 33 F80 Power saving mode 34 F81 Security code 35 F90 Setting of all functions 36 F96 Check of suction command signal 38 F98 Check of output 39 F99 Reset to the default setting 41 Other Settings
NO.ZK2-OM00801-B // ZK2-ZSV-A A 2 9 10 11 14 14 15 16 16 17 17 20 20 20 F0 22 F1 OUT1 23 F2 OUT2 25 F3 27 F4 28 F6 30 F11 31 F80 32 F81 33 F90 34 F96 36 F98 37 F99 39 40 B 43 44 45 51 52 52 -1NO.ZK2-OM00801-B (ISO/IEC)(JIS)1)2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems.
Function selection mode 22 Default setting 22 F0 Unit selection function 24 F1 OUT1 25 F2 OUT2 27 F3 Response time 29 F4 Auto-preset 30 F6 Fine adjustment of display value 32 F11 Display resolution 33 F80 Power saving mode 34 F81 Security code 35 F90 Setting of all functions 36 F96 Check of suction command signal 38 F98 Check of output 39 F99 Reset to the default setting 41 Other Settings
Product Number ZME-ZSE***-A Table of Contents Safety Instructions 2 Model indication and How to order 9 Summary of Product parts 10 Definition and terminology 11 Mounting and Installation 14 Installation 14 Wiring 15 Wiring 15 Internal circuit and wiring example 16 Easy Setting 17 Measurement mode 17 Function Setting 20 Function selection mode 20 Default setting 20 F0 Unit selection function 22
Air supply .22 5-4. Piping .22 5-5. Operating environment .23 5-6. Lubrication .23 6. Maintenance or inspection .23 6-1. Maintenance or inspection .23 6-2. Replacement part .24 6-3. Maintenance .24 1 - Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
(Allowable inclination difference in the vertical direction is 5) 3) For IDF60, mount male elbow (width across flats: 22) to the drain outlet port (width across flats: 27). For IDF70, IDF80 and IDF90, mount male connector (width across flats: 22) to the drain outlet port (width across flats: 22) and mount the drain tube.
(Allowable inclination difference in the vertical direction is 5) 3) For IDFC60, mount male elbow (width across flats: 22) to the drain outlet port (width across flats: 27). For IDFC70, IDFC80 and IDFC90, mount male connector (width across flats: 22) to the drain outlet port (width across flats: 22) and mount the drain tube. Note 1) Apply sealant tape or sealant to fit the nipple.