When an actuator, such as a cylinder, is to be driven using a valve, take appropriate measures (such as the installation of a cover or the restricting of access to the product) to prevent potential danger caused by actuator operation. 12.
Recommended proper torque Nm Connection threads 1/2 M5 1/8 1/4 3/8 3/4 1 28 to 30 1.5 to 2 7 to 9 12 to 14 22 to 24 28 to 30 36 to 38 Torque 2. Twisting moment or bending moment other than the dead weight of the equipment should not be applied. To avoid damage, external piping should be supported separately from the product. 3.
Piston assembly Valve Valve spring No. 4 5 6 1348104A 1348105 1348109 SUP OUT 2 ARX Series Specialty Regulators Regulator for 290 psi (2 MPa) ARX20, 21 Dimensions Panel cutout dimensions 1.02 (26) R .1 (2.5) SUP OUT SMC K C O P A A L U S H .5 (12) 1.61, 2.13 [41 (K40)], [49 (K50)] 2.13 (54) .98 (25) 1.6 (max. thickness 4.5) 1.73 (44) .21 (5.4) 3.13 (79.5) (when regulating pressure = 3.23
(For type 20, 41, 42 and 45) Pilot pressure range SS5YA Fill the same as SS5Y . 3 5 7 3 5 7 Pilot pressure MPa Specify the part numbers for valves and options together beneath the manifold base part number. (Example) SS5YA5-42-03-02 1 set (Type 42, 3 station manifold base part no.) SYA5140 1 set (Single air operated valve part no.) SYA5240 1 set (Double air operated valve part no.)
3 Stainless steel Spool spring 3.5-41 VZM500 Series VZM500 Basic/VZM550-01-00 JIS Symbol SlA VlA SlA VlA 16N F.O.F. 0.5MPa supply 1mm P.T. 2mm O.T. VM/VR 3mm T.T. VH Roller Lever/VZM550-01-01, VZM550-01-01S JIS Symbol 8N F.O.F. 0.5MPa supply 2.2mm P.T. 4mm O.T. 6.2mm T.T.
PSE ZS-26-J IS ISG Specifications ZSM PSE532 (Low pressure) Model PSE530 (Positive pressure) PSE531 (Vacuum) PSE533 (Compound pressure) Rated pressure range 0 to 101 kPa 0 to 1 MPa 0 to 101 kPa 101 to 101 kPa 10.1 to 0 kPa 0.1 to 0 MPa 10.1 to 0 kPa Extension analog output range Proof pressure 500 kPa 1.5 MPa Applicable fluid Air/Non-corrosive gas/Non-flammable gas Power supply voltage 12
Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 01 02 03 04 05 06 07 11 12 13 21 22 23 24 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 Connection size Piping connection method Symbol Size and model no.
Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 Nozzle size Nil 01 02 03 04 05 06 07 11 12 13 21 22 23 24 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 Connection size Piping connection method Symbol Size and model no.
The ZB is available as a single unit or mounted to a manifold of up to 12 stations. Manifold for compact ZB ejector/vacuum pump system, Up to 12 stations available as standard, Mountable or non-mountable base for sensor/switch, MANIFOLD, VACUUM EJECTOR, M02, 41 lb
Recommended proper torque Nm Connection threads 1/2 M5 1/8 1/4 3/8 3/4 1 28 to 30 1.5 to 2 7 to 9 12 to 14 22 to 24 28 to 30 36 to 38 Torque 2. Twisting moment or bending moment other than the dead weight of the equipment should not be applied. To avoid damage, external piping should be supported separately from the product. 3.
-90-20 FAX: 67-12-90-21 NEW ZEALAND SMC Pneumatics (New Zealand) Ltd. 8C Sylvia Park Road Mt.Wellington Auckland, New Zealand TEL: 09-573-7007 FAX: 09-573-7002 BELGIUM (Distributor) SMC Pneumatics N.V.
- (mm) L1 L2 L3 L4 L5 L6 16 5 MHM-16D 1 1 1 1 MHM-25D 36 34 MHM-32D 50 24 MHM-50D 23 25 80 41 / 3 NPN 3 PNP PLC PLC 2 2 PLC PLC PLC PLC -13- AND(),OR() *50ms 3 NPN OR 3 NPN AND 1 1 1 2 2 2 3 PNP AND 3 PNP OR 1 1 1 2 2 2 2 AND 2 OR 2 AND ON , 2 ON 20V 2 OR OFF OFF 1 1 ON 2 2 ON =-2 OFF =2 =1mA2 3k =6V 3k 1mA =24V-4V2 =16V DC24V 4V 2-8.
No.PS-OME0003CN-F / / PSE53 SMC 2 8 8 9 9 11 12 12 14 -1No.PS-OME0003CN-F (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating industrial robots-Safety
When any vibration, impact, or load is applied to the manifold, be sure to use the direct mounting manifold. 12 No.JSY1000V-OMW0002-B JSY1000/3000/5000 series Specific Product Precautions 5 Be sure to read this before handling.
1 12 !3 Scraper Rod seal 12 is a non-replaceable part, so it is not included in the seal kit. Set of left nos. o, !0, !1, !3 Piston seal NBR Piston gasket Tube gasket CHQ100-PS Seal kit consists of items o, !0, !1 and !3 and can be ordered by using the seal kit number for each bore size. Special tool required for disassembly. Contact SMC for recommended tool designs and dimensions.
1 12 !3 Scraper Rod seal 12 is a non-replaceable part, so it is not included in the seal kit. Set of left nos. o, !0, !1, !3 Piston seal NBR Piston gasket Tube gasket Seal kit consists of items o, !0, !1 and !3 and can be ordered by using the seal kit number for each bore size. Special tool required for disassembly. Contact SMC for recommended tool designs and dimensions.
1.5 4 4 7 14.4 4.7 80 M4 x 0.7 26 JS16-5-080 12 13.5 16 2 6 5 10 19 5.8 0.5 210 M5 x 0.8 34.5 JS20-8-125 M8 x 1.25 44 15.5 21 4.5 7 7.8 13 24.8 7.3 0.5 1100 JS32-10-125 M10 x 1.25 49.5 17.5 24 5 8 8.5 17 29 8.5 0.5 2500 JS40-14-150 M14 x 1.5 60 18.5 31 5 11 11.6 22 38.4 11.6 0.75 6000 JS63-18-150 M18 x 1.5 74.5 23 41 7 14 14.3 27 49.2 14.3 1 11000 3
The ZB is available as a single unit or mounted to a manifold of up to 12 stations. Manifold for compact ZB ejector/vacuum pump system, Up to 12 stations available as standard, Mountable or non-mountable base for sensor/switch, Manifold, 5 stations, VACUUM EJECTOR, M02, 41 lb
(inch) Connection thread UNF NPT