selection function Note 12) NPN 2 outputs F SI unit only Note 13) -100 to 100 H PNP Unit selection function Note 12) 2 outputs J SI unit only Note 13) K Unit selection function Note 12) NPN Pressure switch for 1 output Q SI unit only Note 13) -100 to 100 vacuum with energy R PNP Unit selection function Note 12) saving function Note 11) 1 output S SI unit only Note 13) N Without pressure
Indication of A B C D E F G T VCKH1209-02F VCKH1008-02F VCKH1075-02F VCKH0806-02F VCKH0604-02F 12/9 13 38.5 10 19 17 18.5 9 to 12 Nm 10/8 11 38 9 17 17 18.5 6 to 9 Nm 1075 11 38 9 17 17 18.5 6 to 9 Nm 8/6 9 36.5 8 14 14 16 4 to 9 Nm 6/4 7 36.5 8 12 14 15 3 to 8 Nm VCKK 40 swivel elbow 40 B A 10 Approx. F D Width across flats 14 Tightening torque: Tighten within 10 1 Nm. Approx.
AWD ITV Wiring diagram Current signal type Voltage signal type VBA Brown Brown VE Blue Blue Vs Vs White White VY Black Black A Vin G 24V DC 12 to 15V DC 4 to 20mA DC 0 to 20mA DC Vs: Power supply Vs: Power supply 24V DC 12 to 15V DC 0 to 5V DC 0 to 10V DC AL Vin: Input signal A : Input signal Preset input type Brown Blue S1 White Vs Black S2 Vs: Power supply 24V DC 12 to 15V DC One of the
Description Size 1 Valve Rc1/2 2 Valve Rc1 3 Y-strainer (#40) Rc1 4 Flow metter Prepare a flow metter with an appropriate flow range. 5 Valve (Part of thermo-chiller) Rc3/4 6 Y-strainer (#40) Rc1/2 3.4 Piping HRS Series 3-28 HRX-OM-W032 Chapter 3 Transport and Setting Up 3.5 Circulating Fluid Supply 3.5.1 Automatic water fill function When clear water is used, refer to 7.1 Quality Control
VCA20-12-1A VCA30-12-1A VCA40-12-1A Connector Mounting screws (2 pcs.)
No anchor bolt is included. 77 A HRS090 Series Standard Type Cooling Capacity HRS090-A-20/40 (50 Hz) HRS090-A-20/40 (60 Hz) 12 12 10 10 Ambient temperature 32C Ambient temperature 32C Cooling capacity [kW] Cooling capacity [kW] 8 8 Ambient temperature 40C Ambient temperature 40C 6 6 4 4 Ambient temperature 45C Ambient temperature 45C 2 2 0 0 5 10 15 20 25 30 35 Circulating fluid temperature
m AFJ20-02-40-S/AFJ30-03-40-S/AFJ40-04-40-S AFJ20-02-40-T/AFJ30-03-40-T/AFJ40-04-40-T 12 12 AFJ20-02-40-T AFJ30-03-40-T AFJ20-02-40-S AFJ30-03-40-S AFJ40-04-40-S 10 10 Pressure drop [kPa] Pressure drop [kPa] 8 8 AFJ40-04-40-T 6 6 4 4 2 2 Water drop removal type Nominal filtration rating: 40 m Large flow type Nominal filtration rating: 40 m 0 0 0 100 200 300 400 500 600 800 700 900 Flow rate
C Facility water temp. +15C Circulating fluid rated flow rate L/min 4 30 40 40 (1.1 [gal]/min) (7.9 [gal]/min) (10.6 [gal]/min) (10.6 [gal]/min) Facility water minimum necessary flow rate L/min 10 20 25 40 (2.6 [gal]/min) (5.3 [gal]/min) (6.6 [gal]/min) (10.6 [gal]/min) Operating temperature range C 20 to 90 Temperature stability *1 C 0.3 Circulating fluid *2 Galden HT200 or FluorinertTM
Mode button 1s Set button 1s or Mode button 1s Set button 1s B D C Fig. 40 No.DIG-31900-OM002 49 B Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 40-1 C Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 40-2 D Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant
MK MK Body option Bore size Nil N Standard (Female thread) 12 16 20 25 32 40 50 63 12 mm Port thread type MK2T With arm 16 mm M thread 12 to 25 Arms are shipped together, (but not assembled). 20 mm Nil CK1 Rc NPT G 25 mm TN TF 32 to 63 32 mm Rotary direction (Unclamp Clamp) CLK2 Port side 40 mm 50 mm Counterclockwise R L Clockwise During unclamping (Extension end) R type (Clockwise) CLKG
(AR20(K)/25(K)/30(K)/40(K)) AR10 AR20(K) AR25(K) AR30(K) AR40(K) AR20(K)/25(K)/30(K)/40(K) Hook spanner Nominal Tightening torque 2.0 0.2 Nm 2.5 0.2 Nm 3.5 0.3 Nm 4.0 0.4 Nm AR20(K) AR25(K) AR30(K) AR40(K) AR20(K) AR25(K) AR30(K) AR40(K) 34/38 40/42 52/55 52/55 Assembly (Bracket assembly) 1) Mount the bracket to the product.
(AR20(K)/25(K)/30(K)/40(K)) AR10 AR20(K) AR25(K) AR30(K) AR40(K) AR20(K)/25(K)/30(K)/40(K) Hook spanner Nominal Tightening torque 2.0 0.2 Nm 2.5 0.2 Nm 3.5 0.3 Nm 4.0 0.4 Nm AR20(K) AR25(K) AR30(K) AR40(K) AR20(K) AR25(K) AR30(K) AR40(K) 34/38 40/42 52/55 52/55 Assembly (Bracket assembly) 1) Mount the bracket to the product.
66 33 40 66 30 38 63 51 67 4 2.5 1.8 1.6 d 8 5 KQB2 Applicable tubing 4 3 2.3 2.6 H1 H2 KS KX 6 4 3.3 6 10 5.8 M A L KM 14 8 6 14 6.6 5.3 17 Connection thread 17 KF 17 25 10 7.5 6.8 30 M 22 27.1 17 7.6 17 25 H/DL L/LL 10 8 7.3 35 22 27.1 KC 17 26.6 12 9 8 45 22 28.7 17 8.5 KK 17 26.6 12 10 9 57 KK130 22 28.7 28 29.9 16 13 22 9.3 12 101 22 DM Reference dimensions after installation of R
Centigrade (oC)Fahrenheit (oF) 5.13 12 Changing pressure unit Pressure unit can be changed.
0 10 20 30 40 0 10 20 30 40 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSE024-A-20/23-(T) [50 Hz] [60 Hz] 3000 3000 Ambient temperature Ambient temperature Cooling capacity [W] Cooling capacity [W] 25C 2500 2500 25C 2000 2000 1500 1500 35C 35C 1000 1000 40C 500 500 40C 0 0 0 10 20 30 40 0 10 20 30 40 Circulating fluid temperature [C] Circulating fluid temperature
: Red (+) 2 x 4.2 (Mounting holes for manifold) 20 2 x 1/4" {A (4), B (2) port} 42 (14) 1.2 (52) (2 x 4.2 Mounting holes) 44 (For E type) (49.5) 0.3 mm2 (42.5) 40 40 14.7 125 (39.4) 123.3 L (Lead wire length) 1/4" {P (1) port} 2 x 1/8" {EA (5), EB (3) port} 39.4 0.9 18 2 1.2 (23.9) EB P EA 39.5 13 36 2 x 2.2 (Positioning for manifold gasket) (66) L plug connector with cover (LL) 52-SY7120
2ywr e 11 Stainless steel 304 Thread 12 PVC Lead wire !
Standard Strokes Bore size (mm) 20 32 40 50 63 80 100 Standard strokes (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Hydraulic Fluid Compatibility 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Hydraulic fluid Compatibility
50 75 100 125 150 175 200 250 300 Reed switches: D-Z7, Z8 Solid state switches: D-Y5, Y6, Y7 Female threads Male threads 180 Single rod Double acting CQ2 200 Double rod New 180 and 200 Compact cylinder variations A wide range of 15 sizes from 12 to 200 Bore size (mm) Compact cylinder series 12 16 20 25 32 40 50 63 80 100 125 140 160 180 200 CQ2 Large bore CQ2 CQS Refer to N320 "CQ2" and