By continuously turning the 24 VDC power ON/OFF, the fluid flows from the suction port to the discharge port . The pump performs suction with its own power even without priming. Idle run of the pump shall be 3 minutes or less for the intake of the liquid. 4. To stop the pump turn OFF the 24 VDC power.

By continuously turning the 24 VDC power ON/OFF, the fluid flows from the suction port to the discharge port . The pump performs suction with its own power even without priming. Idle run of the pump shall be 3 minutes or less for the intake of the liquid. 4. To stop the pump turn OFF the 24 VDC power.

SMC + 12 to 24 VDC Brown Gray LED Green kPa Main circuit PLC Input terminal RESET SET Black Tr1 D1 LED Red PLC Input terminal Tr2 D2 White COM Blue How to Use Connector 1. Attaching and detaching connectors When assembling the connector to the switch housing, push the connector straight onto the pins until that lever locks into the housing slot.

(Power supply ripple: 1% or less) Power supply 50 mA Current consumption 0.01 mm (With 4 times multiplication) Resolution 0.02 mm(1) (at 20C) Accuracy Open collector (24 VDC, 40 mA) Output type Made to Order Specifications Click here for details A/B phase difference output Output signal 500 VDC, 50 M or more (between case and 12E) Insulation resistance Symbol Specifications 33.3 Hz 6.8 G

Nil R Left to right Right to left 110 to 120 VAC (50/60 Hz) Note) The grommet type can have a surge voltage suppressor (direct coupling type lead wire), but without indicator light. 220 VAC (50/60 Hz) 24 VDC 12 VDC Manual override 240 VAC (50/60 Hz) Non-locking push type (Flush type) Locking type (Tool required) Locking type (Lever type) Nil B C TV approved product Conforms to standards necessary

50 mA Resolution 0.1 mm/pulse Accuracy 0.2 mm Note) Model Series Type Action Bore size (mm) Lock action Output type Open collector (Max. 35 VDC, 80 mA) Note) CE2 Non-lube Double acting 40, 50, 63 80, 100 Spring and pneumatic lock Output signal A/B phase difference output Insulation resistance 50 MW or more (500 VDC measured via megohmmeter) (between case and 12E) Vibration resistance 33.3

Rated voltage 5 6 24 VDC 12 VDC For lead wire lengths other than 300 mm, refer to the plug connector lead wire (page 5). Applicable Auto Switches / Refer to pages 14 through to 16 for detailed auto switch specifications.

156 k/625 k/ 2.5 M/5 M/10 Mbps 125 k/250 k/ 500 kbps Communication speed 4-branch input Specified file Note 2) EDS file GSD file 64/64 Possible to change depending on the switch setting 96/96 (3 stations, remote device station) Possible to change depending on the switch setting Occupied area (Number of inputs/outputs) 4-branch output Not applicable Applicable Terminal resistor 11 to 25 VDC

P 24 VDC, Positive common PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins) P12 12 VDC, Positive common N 24 VDC, Negative common LOCK FREE LOCK FREE N12 12 VDC, Negative common Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors SUP/EXH block fitting type Pilot type Straight Nil Nil Internal pilot Elbow (Upward) L

, 600 or less with 24 VDC output Power supply voltage 12 to 24 VDC 10% Current consumption 20 mA or less (without load) Enclosure Environmental resistance IP65 Operating: 0 to 50C, Stored: 25 to 85C in stock (with no condensation and freezing) Operating temperature range Voltage resistance 1000 VAC for 1 min. between external terminals and case Insulation resistance 50 M or more (500 VDC

Step Motor (Servo/24 VDC) Electric Rotary Table How to Order LER10, 30, 50 Series LER RoHS LER 10 1 1 S K 6N q w e r t y u i o !

Compact Electro-Pneumatic Regulator Series ITV0 RoHS How to Order For single unit and single unit for manifold ITV00 1 0 0 N Pressure range 0.1 MPa 0.5 MPa 0.9 MPa Cable connector (Option) 1 3 5 Power supply voltage Without cable connector Straight type 3 m Right angle type 2 m N S L 24 VDC 10% 12 to 15 VDC 0 1 Input signal Current type 4 to 20 mA DC (Sink type) Current type 0 to 20 mA DC

IR Power supply voltage IRV 0 24 VDC Cable connector type VEX Straight type 3 m Input signal 0 Current type 4 to 20 mA DC 1 Current type 0 to 20 mA DC 2 Voltage type 0 to 5 VDC 3 Voltage type 0 to 10 VDC 40 4 points preset input type SRH S SRP SRF Right angle type 3 m ITV Monitor output Nil None (Preset input only) 1 Analog output 1 to 5 VDC 2 Switch output/NPN output 3 Switch output/PNP

Set pressure range 3 0.01 to 3.0 MPa Cable connector type Straight type 3 m Power supply voltage 0 24 VDC S Input signal Current type 4 to 20 mA DC (Sink type) 0 Right angle type 3 m Current type 0 to 20 mA DC (Sink type) 1 2 3 L Voltage type 0 to 5 VDC Voltage type 0 to 10 VDC Monitor output N Without cable connector 1 2 3 4 Analog output 1 to 5 VDC Switch output/NPN output Switch output

Micro switch type Min. applicable load Model Piping method Rc 1/4 thread Gasket piping Rc 1/4 thread Gasket piping IS3000-02 IS3100 IS3010-02 IS3110 Standard 5 VDC 160 mA Micro load 5 VDC 1 mA Easy electrical wiring Wide space for wiring. Fixed wiring possible with G 1/2 connector.

Types S, Z 24 VDC: 7 to +10 %, 12 VDC: 4 to +10 % Type T 24 VDC: 8 to +10 %, 12 VDC: 6 to +10 % Note 1) Impact resistance: Made to Order Specifications (For details, refer to pages 1847.) Symbol Specifications No malfunction resulted from the impact test using a drop impact tester.

Compatible motor Actuator part number P Step motor (Servo/24 VDC) (Except cable specifications and actuator options) Example: Enter LEMB25T-300 for the LEMB25T-300W-S12N1.

VQC 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 3 Electrical entry VQZ 110 to 120 VAC, 50/60 Hz G: Grommet E: Grommet terminal T: Conduit terminal D, Y: DIN terminal 4 3 position exhaust center 220 VAC, 50/60 Hz 5 6 24 VDC 12 VDC SQ 4 7 240 VAC, 50/60 Hz Note) VFS 9 Other 3 position pressure center Option Note) L and M plug connectors: Max. 220 VAC VFR 5 L: L plug connector M: M plug