Local Area: (800) 258-9200-www.stevenengineering.com Fluid Air/Inert gas VT 1.0 MPa Maximum operating pressure Minimum operating pressure 0.1 MPa VP 1.5 MPa Proof pressure Ambient and fluid temperature 10 to 50C Lubrication Not required Dusproof (5) VG Enclosure Manual override Push type (Safety style), Locking type (Tool required), Locking type (Manual) VP Shock/Vibration resistance (m/s2) 150
/50 m/s2 (2) (A) 4 (B) 2 VF IP65 (Dust/Splashproof type) 12 VDC, 24 VDC 15 to +10% of rated voltage Equivalent to Class B 1.8 W DC (75 mA) 1.8 W DC (150 mA) VFR 1 (P) 5 (R1) 3 (R2) Allowable voltage fluctuation Type of coil insulation Power consumption 24 VDC 12 VDC 3 position closed center VP4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office
Inch size 1/4" 1/8" 5/32" Flow rate (l/min(ANR)) 170 100 120 150 IN OUT Effective area (mm2) 2.6 1.5 1.8 2.3 IN P1 Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20C.
When selecting a converter by its nominal diameter, the converters oil level speed should be 0.2 m/s or less. 25 600 500 400 100 CRA1H100-180 200 20 CRA1H100-90 300 300 100 CRA1H80-180 200 200 150 CRA1H80-90 50 CRA1H63-180 Step (3) Select required function for valve unit 100 100 80 CRA1H63-90 Select a model from data (B),
CQ2 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 Built-in Magnet Cylinder Model Double acting Action D 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 RQ If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch. (Example) CDQSL25-30D 25 For Manufacture of Intermediate Strokes, refer to page 552.
Graph (2) MK50/63 When arms moment of inertia is 3 x 104 kgm2, cylinder speed should be less than MK20/25: 65 mm/s MK32/40: 150 mm/s. For calculating moment of inertia, refer to front matter 1, 2, back page 8. Note) Maximum piston speed is equivalent to approximately 1.6x the average piston speed.
Optimum operating position D-M9A(V) D-M9W(V) Series Variations Standard stroke (mm) Rod end configuration Action Type Size 5 10 15 20 25 30 35 40 45 50 75 100 125 150 175 200 250 300 Single rod 25 32 Double acting 40 Double rod 50 Male thread, Female thread 63 Spring return, Spring extend 25 32 Single acting 40 50 63 Features 1 Series MU Rod End Allowable Load Y axis X axis In case of a plate
M9BW With auto switch CDM3 L 150 40 With auto switch (Built-in magnet) Number of auto switches Rod end thread Nil S n Mounting Bore size 2 pcs. 1 pc. n pcs.
(mm) Maximum suction flow rate (l/min (ANR)) Air consumption (l/min (ANR)) Weight (With bracket) (kg) Model ZR1-W10S ZR1-W13S ZR1-W15S ZR1-W18S ZR1-W20S 0.132 0.134 0.136 0.154 0.156 46 78 95 150 185 22 38 54 62 84 1.0 1.3 1.5 1.8 2.0 ZA ZX Model/Max. Vacuum Pressure 53 kPa (L: Large flow type) ZR Nozzle dia.
(not including sensor accuracy), Response time: 150 ms or less Accuracy (to display value) (25C) 1.0% F.S. or less 1.5% F.S. or less 2.0% F.S. or less 0.5% F.S.
(Not including sensor accuracy), Response time: 150 ms or less Accuracy (To display value) (25C) 1.0% F .S. or less 1.5% F .S. or less 2.0% F .S. or less PF2 0.5% F .S.
180 210.5 226 250 135 140 155 134 146 162.5 20 24 24 VNC5-32F VNC6-40F VNC7-50F 100 105 120 36 42 54 12 12 14 310.5 326 350 278 293.5 317.5 VX Port size: 65F, 80F Flange connection VN VQ Applicable flange 65 80 Model H F E D C B A 1 4 1 4 405.5 441.5 65 80 140 150 204 235 175 185 305.5 341.5 210 240 VNC81 -65F VNC91 -80F 4.2-25 VNC Construction N.C.
I ':"1 6 65 274 1 7 7 1 7 7 6 52 55 -r5 loo . 6 . 202 202 6 8 65 320 227 227 6 47 75 litzs . 70 345 252 252 6 47 150 6 8 370 277 2 7 7 r 1 65 T-slot A dimensions T-slot B dimensions $unies tX$ tilo To 0[dEl' tlect|'ic Acl||at0 AC Servo Motor 100vAc TS45O1N -rslsotl I Nole 1) l Applicable Applicable TarnaFwa Sek I 2OOVAC TS45O1N AppLicable L Applicable 3 -.'
x-cov-450-50 xRAY-450-150 Weld SDatter Covers x-cov-450-r 50 To Mount 6.5mm Prox.
SUP = 0.2 MPa 150 100 50 1 0 2 3 4 5 6 7 Caution Cycle (Hz) 1. These flow characteristics are for fresh water (viscosity 1mPas, specific gravity 1.0). 2. The discharge rate differs greatly depending on properties (viscosity, specific gravity) of the fluid being transferred and operating conditions (density, lifting range, transfer distance).
In general, 80 to 100 mesh (150 to 180 m) filters are recommended. When transferring a coagulable liquid, take measures to prevent it from coagulating in the pump. Flammable fluid cannot be used with the process pump with built-in solenoid valve (PB1011A). Do not use in an environment where flammable fumes are present or where flammable liquid may get stuck to the product.
Pressure characteristics*4 2.5% F.S. (0.1 to 1.0 MPa, 0.5 MPa standard) Pressure Electrical Power supply voltage 24 VDC 10% Current consumption 150 mA or less Protection Polarity protection Display accuracy 3.0% F.S. Analog output accuracy 3.0% F.S. Accuracy Repeatability Switch output/Display: 1.0% F.S. Analog output: 1.0% F.S. Temperature characteristics 5.0% F.S.
screen) Line name Expanded flow range Compact, Space saving Wide range of flow measurement with one product Compared with the current PF2A, Flow ratio 78 % reduction Weight 74% reduction 100:1 Mounting space 1100 g a 240 g Compared with PFMC7202-06 and PF2A703H-10 Rated flow ratio is 10 : 1 for current PF2A. 2000 L type 55 Applicable flow range [L/min] PFMC7202 New 1 2 5 10 20 25 50 100 150
Additional weight 0.23/50 stroke Stroke 100 stroke 0.46 + 100 / 50 X 0.23 = 0.92kg Standard Stroke (mm) Size Standard stroke Max. stroke(mm) 25, 32, 40 50, 63 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 75, 100, 125, 150, 175, 200, 250, 300 300 Contact SMC for any intermediate strokes that are not indicated above, as they will be produced upon receipt of order.
Note 3) For detailed specifications other than the above, refer to the separate technical operation manual that can be downloaded from SMCs website (http://www.smcworld.com/). 10 to 150 Hz with a 0.035 mm amplitude or 4.9 m/s2 in each X, Y, Z direction for 2 hrs (De-energized) 147 m/s2 in each X, Y, Z direction, 3 times (De-energized) Standard CE marking, UL (CSA) Communication connector