SMC Corporation of America
Elite Part Number Search
Search Results "LEFS25EA-800B-RA"

Mounting: B (Basic Style), Bore Size: 40mm, Thread: TN (NPT), Stroke: 800mm, Stroke Adjustment: B (0 to 50), Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, LED, Lead Wire or Prewired Connector: Z (5m), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC8 (Adjustable Stroke, Extension Type)

Bearing Type: Ball Bushing Bearing, Stroke: 800mm, Motor Option: w/Lock, Actuator Cable Type: Standard Cable, Actuator Cable Length, m: 5, Controller Type: LECP6, Step Data Input Type, NPN, I/O Cable Length, m: 5, Communication Plug Connector: None, Controller Mounting: Screw Mounting, Made to Order: Magnet/Switch Rail

Mounting: Basic Style, Bore Size: 40mm, Thread: NPT, Stroke: 800mm, Stroke Adjustment: 0 to 50, Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, LED, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Adjustable Stroke, Extension Type

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Mounting: Basic Style, Bore Size: 40mm, Thread: Rc, Stroke: 800mm, Stroke Adjustment: 0 to 50, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Adjustable Stroke, Retraction Type

Magnet: Built-In, Mounting: Axial Foot, Style: Non-lube Air Cushion, Bore Size: 50mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 800mm, Stroke Adjust Symbol: 0 to 50mm, Rod Boot: None, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case

Series: Clean Series Ball Screw Drive, Accuracy: Basic Type, Size: 40, Motor Type: Step Motor (Servo/24 VDC), Lead: LEFS16, 5mm; LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm, Stroke: 800mm, Motor Option: w/Lock, Vacuum Port: Left, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: Standard Cable, Actuator Cable Length: 3m, Controller Type: -, I/O Cable Length: -, Protocol: -, Suffix:

Series: 25A-LEFS, Accuracy: Basic Type, Size: 32, Motor Mounting Position: In-line, Motor Type: 200W Output, Incremental Encoder, LECSA, Lead Screw: LEFS25: 6mm, LEFS32: 8mm, LEFS40: 10mm, Stroke: 800mm, Motor Option: w/Lock, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: Standard Cable, Cable Length: 2m

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: L3 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: 02 (Rc1/4), Output Specification: A (Out 1: NPN; Out 2: NPN), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate), Made

Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: L3 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: N7 (1/4), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate),

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: N7 (1/4), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration

Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: N7 (1/4), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate), Made to

Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch.  Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility.  Designed to work with fluids up to 90ºC

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: A (Calibration Certificate), Made to Order:

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: A

Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: A (Calibration Certificate), Made to Order