The VXZ series is a 2 port, pilot operated solenoid valve capable of operating at higher differential pressures by maintaining a zero differential pressure on the seat.
Part Number Description: GUIDE UNIT SLIDE BEARING Product Line: A Product Line Description: ACTUATOR Family Code: 408 Family Description: C95 TIE-ROD CYLINDER Class Code: L2 Part Code: 2 Reference Code: E This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number, GUIDE UNIT, SLIDE BEARING, ACTUATOR
Part Number Description: GUIDE UNIT SLIDE BEARING Product Line: A Product Line Description: ACTUATOR Family Code: 408 Family Description: C95 TIE-ROD CYLINDER Class Code: L2 Part Code: 2 Reference Code: E This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number, GUIDE UNIT, SLIDE BEARING, ACTUATOR
In-line Type Applicable tubing O.D. d Inch Size Metric Size Applicable tubing O.D. d Applicable tubing O.D. d Model Weight D1 D2 L1 L2 M1 L3 Max. Min. (g) Model Weight D1 D2 L1 L2 M1 L3 Max. Min.
, L2, 32MM C95/CP95 ACCESSORY
-L1) Width at closing (mm) (L1) Width at opening (mm) (L2) Weight (g) Model 11221122112211221122112211221122112211221122112211221122112211221122112260 72 94 112 84 126 92 134 172 114 186 340 405 485 660 870 20 40 60 30 60 MHL2-10D MHL2-10D1 MHL2-10D2 MHL2-16D MHL2-16D1 10 40 60 L1 16 40 L2 146 98 158 178 116 226 138 238 278 166 1010 1175 1645 1840 1850 80 40 80 100 50 MHL2-16D2 MHL2-20D MHL2
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 4.
For installation and removal, use an appropriate pair of pliers (tool for installing a type C snap ring). 2. Even if a proper plier (tool for installing type C snap ring) is used, it is likely to inflict damage to a human body or peripheral equipment, as a snap ring may be flown out of the tip of a plier (tool for installing a type C snap ring).
D-A59W Bore size (mm) A B A B A B A B A B A B A B A B A B A B A B 40 50 63 80 9 9 5 5 2.5 2.5 4.5 4.5 2 2 5.5 5.5 3 3 10.5 10.5 0 0 1 1 0 0 9.5 8.5 5.5 4.5 3 2 5 4 2.5 1.5 6 5 3.5 2.5 11 10 0 0 1.5 0.5 0 0 12.5 11.5 8.5 7.5 6 5 3 2.5 5.5 4.5 9 8 6.5 5.5 14 13 2.5 1.5 4.5 3.5 3 2 16.5 13.5 12.5 9.5 10 7 7.5 4 9.5 6.5 13 10 10.5 7.5 18 15 6.5 3.5 8.5 5.5 7 4 100 18 16 14 12 11.5 9.5 9 6.5 11
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
IDX-OM-V022-H Original Instructions PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDF60-20-A,C,L,R,T,V IDF60-30-A,C,L,R,T,V IDF70-20-A,C,L,R,T,V IDF70-30-A,C,L,R,T,V IDF80-20-A,C,L,R,T,V IDF80-30-A,C,L,R,T,V IDF90-20-A,C,L,R,T,V IDF90-30-A,C,L,R,T,V This manual is intended to explain the installation and operation of the product.
Install a power supply transformer or use a different power supply to provide appropriate voltage.
Displacement Use in a strong light source. Check that the Card Motor is not exposed to a strong light source such as direct sunlight. Install a light shielding plate as a cover.
CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution : WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning : DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Do not connect the earth to a water pipe, a gas pipe, or a lightening rod. Do not plug too many leads into a single socket. That causes exothermic heat or fire. Do not modify the internal electrical wiring of the product. 10.2 Specifications An earth leakage breaker is installed in the product.
Devise a safe system so that if a person engages the emergency stop or if a safety device is tripped during a system malfunction,such as a power outage, the operation of the magnet gripper will not cause a hazard to humans or damage the equipment. 7. Consider the action when operation is restarted after an emergency or abnormal stop.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.