SMC Corporation of America
Elite Part Number Search
Search Results "HRS012-AN-10-BM"

Do not use in an atmosphere of corrosive gases, chemicals, sea water, water or water vapor or in an environment where such substances may adhere. 2. Provide shading in an environment where the product is exposed to the sunlight. 3. Do not use in an environment where a heat source is at a close distance. 4. Do not use in an environment where static electricity is a problem.

8 16 10 12 12 8 10 10 41 5 8 31 25 to 300 15.5 25 22 17 32 12 10 16 10 12 12 8 10 10 46 6 8 34 25 to 400 19.5 32 24 22 38 16 14 19 11 13 13 8 10 10 53 8 9 40 25 to 500 21 40 24 24 41 18 16 21 12 17 17 11 16 16 54 10 11 48 25 to 500 21 (mm) Bore size (mm) K NN P S T V W ZZ MM NB IA NA -0.020 -0.053 -0.020 -0.053 -0.025 -0.064 -0.025 -0.064 20 5 M22 x 1.5 1/8 81 9.5 4.5 6.5 138 M8 x 1.25 15

Internal hold External hold MHR2-10/MDHR2-10 MHR2-10/MDHR2-10 20 20 Pressure 0.6MPa Pressure 15 15 Holding force (N) 0.6MPa Holding force (N) 0.5MPa 0.5MPa External hold 10 10 0.4MPa 0.4MPa 0.3MPa 0.3MPa 5 5 0.2MPa 0.2MPa 0 10 20 30 40 50 0 10 20 30 40 50 L L Holding point L (mm) Holding point L (mm) MHR2-15/MDHR2-15 MHR2-15/MDHR2-15 Pressure 0.6MPa 30 30 Internal hold Pressure 0.6MPa 0.5MPa

D-M9W 10 2 pcs. D-M9WV D-M9AV 5 Note 2) 1 pc. 10 2 pcs. 5 Note 2) 1 pc. D-M9A 10 Note 2) 2 pcs. 5 1 pc. D-M9V 5 2 pcs. 5 1 pc. D-A9V 10 2 pcs. 5 1 pc. D-A9 10 2 pcs. 1 pc. 15 D-P3DWA 2 pcs. 15 Note 1) Confirm that it is possible to secure the minimum bending radius of 10 mm of the auto switch lead wire before use.

14 10 14 12 16 20 24 27 38 41 51 37 41 50 41 45 57 42 43 53 72 78 KA 4 2.5 1.8 1.6 10 8 13.5 5 4 3 KQG2 2.3 2.6 Applicable tubing L1 M 6 4 6 10 10 15 5.8 3.3 KG H1 12 d 8 6 KFG2 KFG2 5.3 12 14 17.4 6.6 16 22.2 A L2 23 H2 MS 25.6 10 7.5 6.8 26 Connection thread 27.5 15 17 20.9 7.6 KKA 27 25.6 10 8 7.3 30 KP 27.5 27 25.6 12 9 8 LQ 35 27.5 16 17 23.5 8.5 34 MQR 25.6 12 10 9 44 27.5 31 32.9

(102) 90 (102) 108 (122) 108 (122) 8 10 12 16 20 20 25 30 13 17 17 19 27 27 32 41 24 29 18 22 22 30 35 35 40 40 15.5 35 40 40 50 58 58 71 71 M4 X 0.7 Depth 7 5 5.5 5.5 6 7 7 10 10 1/8 1/8 1/8 1/8 1/4 1/4 3/8 1/2 11 11 11 12 13 13 201 to 350 10 (12) 19.5 16.5 20 26 32 38 50 60 M5 X 0.8 Depth 7.5 301 to 400 10 (12) 19.5 27 32 32 37 37 M5 X 0.8 Depth 8 35.5 44 55 69 80 301 to 450 10 (13)

DS STROKE Bore E B1 B2 B3 TG1 T L1 L3 I1 I2 FL H d1 d2 d3 CN XD 32 45 14 34 3.3 32.5 3 11.5 41 5 5.5 22 10 30 10.5 6.6 10 142 40 55 16 40 4.3 38 4 12 48 5 5.5 25 10 35 11 6.6 12 160 50 65 21 45 4.3 46.5 4 14 54 5 6.5 27 10 40 15 9 16 170 63 75 21 51 4.3 56.5 4 14 60 5 6.5 32 12 45 15 9 16 190 80 95 25 65 4.3 72 4 16 75 5 10 36 16 45 18 11 20 210 100 115 25 75 6.3 89 4 16 85 5 10 41 16 55

M6 x 1 Depth 7.5 39 50 0 77 74 59 155 128 143 3/4, 1 74 46 06 10 06 10 90 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 107 06 10 94 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 111 5 Soft Start-up Valve AV2000/3000/4000/5000 Modular F.R.L.

Order Made Non-Grease Specifications 5 1 Clean Room Specifications Assembly is performed in an ordinary environment without using grease. However, since parts are not washed they are not completely oil-free. Standard part number 10 Note) Contact SMC if equipped with pressure gauge.

Note 5) Air is normally being discharged to the atmosphere from a bleed hole or an exhaust port.

volume Mass 4500 psig (30.7 MPa) 10 psig (69 MPa) 40 to 160F (40 to 71C) (No freezing) 2) 0.09 1 x 10-10 Pam3/sec NPT female, Compression 0.38 pisg (0.0026 MPa) rise in delivery pressure per 100 psig (0.7 MPa) source pressure drop Bottom mount (Option: panel mount) 0.49 in3 (8 cm3) 2.4 lbs (1.09 kg) 3) 1) Max 300 psig (2.1 MPa) for PTFE seat. 2) 14 to 194F (10 to 90C) for Vespel and PEEK

32A VEX9-32A VEX1-18-2A VEX1-18-2A F Foot (With bolt and washer) G27-10-R1-X207 G27-10-01 G36-10-01 G46-10-01 G Pressure gauge AN120-M5 N Silencer for breed port (PE) The optional parts are shipped in the same package.

MU-D02 MU-D03 MU-D04 MU-D05 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.070 0 8 10 10 14 8 10 10 14 Applicable pin no. CD-MU02 CD-MU03 CD-MU04 CD-MU05 DZ 8 10 10 14 CZ 8 10 10 14 DY 9 11 13 16 CX 9 11 13 16 DX 18 22 26 32 CT 9.5 11 14 17 DT 9.5 11 14 17 CR 5.3 6.4 8.4 10.5 DR 5.3 6.4 8.4 10.5 CL 26 42 54 64 DL 26 42 54 64 Part no.

, 13, 15 For nozzle size 18, 20 For nozzle size 10, 13, 15 For nozzle size 18, 20 e r t For nozzle size 10, 13, 15 [For ZSE4 spec.]

Minimum Stroke for Auto Switch Mounting [mm] Auto switch model Number of auto switches Bore size 12 (10 x 2) 16 (12 x 2) 20 (16 x 2) 25 (20 x 2) 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) D-M9V 1 5 2 5 D-M9 1 51 5 2 101 10 D-M9W 1 52 2 102 10 D-M9WV D-M9AV 1 52 2 10 D-M9A 1 52 2 102 1 Confirm that it is possible to secure the min. bending radius of 10 mm of the

An injury or failure can result. Yellow flashing Bus IN side: Link, Activity(10 Mbps) 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.

A L D VQZ D KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 VQD Color: White VZS VFS EXH port silencer VS 63 Silencer is installed in the EXH port.

10 10 90 42 27 45 31 49 190 10 10 80 35 35 62 39 66 190 10 10 65 30 39 68 43 72 190 10 10 50 24 49 83 53 87 Operating angle m: Value of the operating range Lm of a single auto switch converted to an axial rotation angle.

An injury can result. If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident. Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.

Spare elements and O-rings for the cover are sold in sets of 10 pieces each.