. 90 Drive unit 3 Basic type MSUB 7 Double vane D-R73, D-T79 D-R80, D-S79, S7P 180 20 Double vane is available with 90 rotation setting only. 11-5-2 11-5-3 3 Series MSU Precautions Be sure to read before handling.
1 LEF LEJ A A LEL B D-D #3 LEM LEM LEY !6 @3 @3 @5 @4 @7 @2 @4 @5 @1 LES #1 #0 u #2 i y LEPY LEPS !3 C-C A-A LER !8 @6 @8 @9 B w !2 C !7 D LEH LEY -X5 D #4 #4 11LEFS C o !0 !5 11LEJS Motor option: With lock 25A!1 LEC !2 LEC S !3 LEC SS-T @0 LEC Y !9 Motorless LAT Component Parts Component Parts LZ No. Description Material Note 1 Body Aluminum alloy Anodized No.
P D M 8 A L 4.2 D H Connection threads Straight Union: KPQH, KPGH Effective area mm D Model L Applicable tubing O.D. mm Note 1) 2-Applicable tubing Weight g M TPH TPS 4 KPQH04-00 KPGH04-00 10.4 37.4 18 4 4 4 D D 6 KPQH06-00 KPGH06-00 12.8 39.6 19.5 10 10 6 M M L 8 KPQH08-00 KPGH08-00 15.2 44.4 21.5 26 18 10 10 KPQH10-00 KPGH10-00 18.5 48.6 24 41 29 15 12 KPQH12-00 KPGH12-00 20.9 50.6 25 58
P D M 8 A L 4.2 D H Connection threads Straight Union: KPQH, KPGH Effective area mm D Model L Applicable tubing O.D. mm Note 1) 2-Applicable tubing Weight g M TPH TPS 4 KPQH04-00 KPGH04-00 10.4 37.4 18 4 4 4 D D 6 KPQH06-00 KPGH06-00 12.8 39.6 19.5 10 10 6 M M L 8 KPQH08-00 KPGH08-00 15.2 44.4 21.5 26 18 10 10 KPQH10-00 KPGH10-00 18.5 48.6 24 41 29 15 12 KPQH12-00 KPGH12-00 20.9 50.6 25 58
44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.
D 32 9 6 5 10 6 15 6 20 7.5 25 8 D-A9/A9V D-F9W D-F9WV 4.5 2.5 3 3 5 5 5 D-F9BAL D-M9, D-M9V 2.5 3.5 3.5 5 5 2 2.5 3 4 4 4 MX The operating ranges are provided as guidelines including hystereses and are not guaranteed values (assuming approximately 30% variations).
Cylinder specifications 1-2. Lock specifications 1-3. Stop accuracy 1-4. Precautions on model selection P. 6 2. Installation and Handing P. 10 2-1. Air supply 2-2. Design 2-3. Mounting 2-4. Operating environment 2-5. Speed control 2-6. Cushion 2-7. Directional control 2-8. Pneumatic circuit 2-9. Adjustment and Operation 3. How to use P. 17 3-1. Usage 3-2. Lock release mechanism 3-3.
B + First-stage stroke U MK(2) RS Q G RS H A U Mounted on different side in case of a full stroke of 25 mm or less RZQ MI W S B A CEP1 CE1 CE2 [mm] Proper Mounting Position D-A7H,A80H D-A73C,A80C D-F7,J79,J79W D-F7V,J79C D-F7W,F7WV D-F7BAL,F7BAVL D-F79F ML2B D-M9 D-M9V D-F9W D-F9WV D-A79W D-A9 D-A9V C J G5-S D-A7,A80 D-F9BAL D-P5DWL Bore size (mm) CV B A B A B A B A B A B A B A MVGQ 32 27
P. 2-3-44 P. 2-3-46 P. 2-3-47 P. 2-3-48 C6 L6 P R D side SMC AN200 U side Individual EXH spacer SSQ1000-R-3Special wiring specifications (-K) Back pressure check valve (-B) SSQ1000-BP Built-in silencer (-S) P. 2-3-49 P. 2-3-45 P. 2-3-46 P. 2-3-47 C6 L6 D-sub connector Terminal no.
a r t n o P a r t n a m e 0ty A A F M 2 O P _ O 6 O A S t r | o m o n t 7 B A F D 2 O P t ) 6 O A S E I e m e n t 7 C L C J T _ \ , c a s e a s s e m D t y 2 D AD27 -C A u t o d r a i n ?
C D UJB F8N Number of auto switches Nil S 2 pcs. 1 pc.
F G H SUP. 3 1 2 q Body size Description Symbol C D E 20 30 40 Key can be mounted when residual pressure is released.
Note RQB20-PS RQB25-PS RQB32-PS RQB40-PS RQB50-PS RQB63-PS RQB80-PS RQB100-PS D-F7, J79 D-F7V D-J79C D-F7W, J79W D-F7WV D-F7BAL D-F7BAVL D-F79F D-F7NTL Kits consist of piston seal, rod seal and gasket RQ Switch mounting screw (M3 x 0.5 x 10l) Switch spacer Switch mounting nut D-A7, A80 D-A73C, A80C D-A7H, A80H D-A79W 32, 40, 50, 63, 80, 100 BQ-2 CUJ CU [Stainless steel mounting screw kit]
10 2 10 15 20 CXT 32 40 5 15 10 5 1 10 10 20 (mm) D-F7W D-J79W D-F7BAL D-F7NT D-F79F Auto switch model D-A7 D-A8 D-A73C D-A80C D-A7H D-A80H D-F7 D-J79 D-F7V D-J79C D-F7WV D-F7BAVL D-A79W Application No. of auto switches mounted 2 5 10 15 15 20 20 CXT 32 40 1 5 5 10 15 15 20 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.
switch D-F9BA 2-wire Auto Switch Specifications D-F9BAL Auto switch part no.
O e b u t ) h c n i ( . n i M e l o h . a i d t h g i e W ) g ( d a e r h T ) T P ( R . o N t r a P H ) . x e H ( D 1 D 2 L1 L2 * A M R(PT) 6 1 / 3 8 / 1 S 1 0 5 0 T 2 Q K 0 1 4 . 1 1 0 1 5 . 9 1 5 . 2 2 4 2 5 . 6 1 6 2 1 4 / 1 S 2 0 5 0 T 2 Q K 4 1 5 . 6 2 6 2 1 2 8 / 1 S 1 0 7 0 T 2 Q K 0 1 2 . 3 1 0 1 5 . 0 2 5 . 3 2 6 2 7 1 6 . 4 2 1 4 / 1 4 / 1 S 2 0 7 0 T 2 Q K 4 1 5 . 7 2 8 2 2 2
) 3-wire (Reed switch, NPN) 2-wire (Reed switch) Brown Brown Brown Indicator circuit Load 2-Color indication circuit Load 2-Color indication circuit Black Load Contact protection box Contact protection circuit Blue Blue Blue Contact Protection Box/CD-P11, CD-P12
Caution
Note 2) Only non-magnetic material is permitted as the mounting surface of a 20 cylinder. 25, 32, 40 (mm) Applicable switch model Bore size (mm) D-Z7, Z80, Y59, D-Y7P, Y7W A B C D 25 18 99 43 74 32 21.5 108.5 46.5 83.5 40 23.5 124.5 48.5 99.5 Note 1) 50mm is the minimum stroke available with 2 auto switches mounted. Note 2) The above dimensions are given as reference dimensions.
3.2 D-M9B (2-wire) OUT Black Most sensitive position 6 DC(-) Blue 22 D-M9B OUT(+) Brown OUT(-) Blue 18