) 24VDC (10%) 24VDC (10%) 100 to 240VAC (10%) 100 to 240VAC (10%) 100 to 240VAC (10%) 24VDC (10%) 100 to 240VAC (10%) Power consumption 20VA or less 10W or less 20VA or less 10W or less 20VA or less 10W or less 10W or less 20VA or less Between case and AC line: 1500VAC for 1 min.
4, 2 5, 3 (A, B EA, EB) Bore size Positions C 10 12 10 12 10 11 10 11 10 13 7.2 7.2 b 0.18 0.24 0.18 0.24 0.28 0.25 0.16 0.26 0.26 0.27 Cv 2.4 3.0 2.4 3.0 2.4 2.8 2.4 2.8 2.4 3.3 b 0.24 0.27 0.24 0.27 0.24 0.27 0.20 0.27 0.25 0.29 Cv 3.0 3.3 3.0 3.3 2.4 2.8 2.4 3.3 2.8 3.0 C 12 13 12 13 10 11 10 13 11 12 7.0 7.0 Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal
1 1 1 2 Rc G NPT NPTF T N F Nil Thread type Double solenoid Single solenoid 81 80 Type of actuation Port size (IN, OUT port) VP3145 VP3165 VP3185 Port size Symbol 03 04 3 8 1 2 06 3 4 Passage, Type of actuation 10 12 1 1 4 1 14 1 2 1 NC NO B A 20 2 In the case of -X80, only N.C. is available.
Size 1 2 1 2 3 1 2 1 2 A B C A B A B A B 2 2 3 3 3 4 4 5 5 2 2 2 3 3 4 4 5 5 1/4" x 5/32" 3/16" x 1/8" 1/8" x 0.086" 3/8" x 1/4" 1/4" x 5/32" 1/2" x 3/8" 3/8" x 1/4" 3/4" x 5/8" 1/2" x 3/8" 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 19 x 16 12 x 10 SMC SMC P U Panel mount union Union SMC SMC With reducer Basic size Note) Select the fittings of the same size as the one at the valve side
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V Selects the analogue input range. (AXB cannot select the following ranges. -10..10 V/ -5..5 V/ -20..20 mA) -5..5 V -10..10 V -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.
rate Nil None (Standard) Symbol Flow rate by size Outlet air flow rate (L/min [ANR]) Standard dew point B With bracket (Except IDG1) (oC) 1 3 5 10 20 60 75 100 Note) When symbol B is indicated, a Nil 20 10 25 50 100 200 600 750 1000 bracket assembly with a part number shown in the table left below is included as an accessory.
PART NUMBER ORIFICE SIZE 1/16 X 10-32 1/8 X 10-32 .003 B-062-003 B-125-003 .004 B-062-004 B-125-004 SPECIFICATIONS .005 B-062-005 B-125-005 ACCURACY: See "Precision Orifices" MATERIAL: FDA Approved Polysulfone/Polycarbonate MAX.
10 14 14 22 22 14 14 20 20 30 30 CZ ZZ + Stroke 6 Series MB1 Cushion Bracket/Double Clevis Mounting Bracket Models Bore size MB32 MB40 MB50 MB63 MB80 MB100 Description Double clevis mounting bracket MB-B03 MB-B05 MB-B08 Double clevis mounting bracket Z + Stroke B DX DB DD B 90 4-DT B A DH DA DL DU DU 4-DR DE DC DO DO DS Without air cushion (mm) B Bore size (mm) No.
For detailed specifications, refer to page 10-20-1. Electrical entry (Fetching direction) D-Z80 Reed switch Grommet (In-line) Type Model Features Without indicator light Normally closed (NC = b contact), solid state switch (D-Y7G/Y7H type) are also available. For details, refer to page 10-20-41. 10-16-20
LEFT RIGHT 35.5 A : B : C : D : t : 10 sec or more required 80 4 56 DOWN 2.5 sec or more required SEL.
RS M W V T2 Applicable mounting bracket Bore size (mm) Weight (g) Joint 2D through 2O counter bore T1 B E J A type mounting bracket B type mounting bracket 32, 40 YU-03 YA-03 YB-03 25 50, 63 YU-05 YA-05 YB-05 40 Material: Carbon steel (nickel plated) mm 80 YU-08 YA-08 YB-08 90 100 YU-10 YA-10 YB-10 160 Bore size (mm) Part no.
(Assuming approximately 30% dispersion) There may be the case to change substantially depending on an ambient environment. 4 4 4.5 5 6 6.5 6.5 7 8 10 9 10 10 11 D8 10 9 10 10 11 5 5 5.5 6 7 7.5 7.5 8 11 11 13 13 14 14 14 17 35 40 40 45 45 45 45 50 16 18 -X 8 10 9 10 10 11 Individual -X 387 Series MGG Auto Switch Mounting Bracket: Part No.
set unit Note 1) Accumulated pulse flow rate exchange value (Pulse width: 50 ms) Note 1) 0.1 l/pulse 0.5 l/pulse 1 l/pulse 2 l/pulse 5 l/pulse l/min, CFM x 10-2 l, ft3 x 10-2 l/min, CFM x 10-1 l, ft3 x 10-1 Display units Real-time flow rate Accumulated flow Note 1, 2) 0 to 9 l, 0 to 9 ft3 x 10-2 0 to 9 l, 0 to 9 ft3 x 10-1 Accumulated flow range Note 1) Power supply voltage Current consumption
B 15 CJP 10 H4 Made to Order Refer to the table below. Pin cylinder Mounting Rod end thread B S Panel mount type Embedded type Nil B With thread Without thread Bore size Hose nipple (Applicable to the mounting type B panel mount type (6 to 15) only.) 4 6 10 15 4 mm 6 mm 10 mm 15 mm (Hose nipple is not attached to embedded style.)
A at the station with the smaller number in the above figure and the B side solenoid to SOL. A at the next station. 1 2 3 4 5 6 7 8 9 10 Terminal no. (Looking it by the double solenoid valve) SOL. () A B () () A B A B A B A B Note) Types with 10, 16, or 20 pin are also available. For details, refer to page 2-4-28.
4-4.5 (For mounting) 9 + 45.6 13.4 + + 2.5 2.5 12.5 15.2 2 123 [127.4] 107 [111.4] 10 18.5 23.5 One-touch fitting 6, 1/4" (A, B port) R P R R P R 16.5 16.5 A B A B A B A B A B 77.6 [79.8] 45 49 77 [79.2] 65 Applicable tubing O.D.: 4, 5/32", 6, 1/4" 82.8 16.5 + + + + + (3.2) Triangle mark 52.8 1/8 (P, R port) (Pitch) P = 17.5 21 (Station 1) (Station n) (Light/surge voltage suppressor) 48.6
Terminal LE CP B Cable colour Terminal number number Brown 2 A B-1 Red 1 A A-1 Cable length [L] Orange 6 B B-2 Yellow 5 B A-2 8 8mNote) Green 3 COM-A/COM B-3 Blue 4 COM-B/ A-3 A 10mNote) (c) Shield B 15mNote) Cable colour Terminal number Brown 12 Vcc B-4 C 20mNote) Black 13 GND A-4 Red 7 A B-5 Note) Produced upon receipt Black 6 A A-5 Orange 9 B B-6 of order Black 8 B A-6 (Only "Robotic
(mm) CD hole H10 Shaft d9 CL CD CT CU CW CX CZ L A B 63 107 55 30 to 100 93 14 8 20 30 22 44 8 80 129.5 63.5 40 to 100 111.5 18 10 27 38 28 56 10 100 155 76 L CU CW RR 40 to 100 133 22 13 31 45 32 64 12 +0.4 +0.2 0.1 0.3 CX CZ B + Stroke CL + Stroke A + Stroke Bore size (mm) Stroke range (mm) 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75, 100 L1 N RR Rod end male thread 63 33.5 M10 x 1.5
10 Reserved Remote DY#B (Unit 0) (Wireless channel 002) byte 11 Reserved Reserved byte 12 DX#D (Unit 1) byte 13 Remote (Wireless channel 002) byte 14 DX#B (Unit 2) byte 15 Reserved Total 16 byte 12 byte Diagnostic allocation: Simple Input data Output data Module name Unit name Module name Unit name DY#B (Unit 0) byte 0 System diagnosis 1 byte 1 System diagnosis 2 EX600-WPN# (Unit 2) Base