AC, DC C.O. 7.5 55 6 45 50 42 18 60 37 12 AC Cv converted Av x 10 6 (m 2 ) VX32 AC (Full wave rectification) 50/60 10 8.5 60 1 3 5 0.08 1.5 1.0 0.6 220 1.9 VX311 -00 DC 8.5 60 11 60 9.5 50 1 3 5 0.16 0.5 0.3 220 3.8 VX312 -00 50 55 22 60 47 18 AC 0.6 370 VX3225-00 2.2 0.19 4.6 VX33 1.0 530 VX3325-00 AC (Full wave rectification) 50/60 14 11.5 60 1 3 5 0.24 DC 11.5 60 0.3 0.2 5.8 220 1.0
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Spanner spout, hexagon Model Port size P Rc A B C D E F With bracket Port size G H I J 1 8 1 4 1 4 3 8 10 VXA21 VXA22 , , 18 21 9 10.5 40 45 21 27 55 62 64 71 11 13 36 46 46 56 11.5 Dimensions (Orifice Size: 8 mm, 10 mm) VXA225/VXA226 Thread fixed: (VXA2262
Frequency (Hz) 50 20 11 60 17 7 Model Power source AC VXR21 50 40 18 60 35 12 DC AC VXR22 50 50 21 60 45 17 DC AC VXR23 DC Operating Fluid and Ambient Temperature Operating fluid temperature (C) Ambient temperature (C) Temperature conditions Power source Water (Standard) Oil (Standard) High temperature water (2) (D) High temperature oil (2) (D) 80 80 AC DC AC/DC 60 40 1 60 40 40 60 Maximum
Frequency (Hz) 50 60(53) 18 60 51(44) 12 Model Power source VX3 7.5 6 8 11 9.5 11.5 AC VXZ22 VXA DC 50 80 21 60 67 17 AC VXZ23 VN DC LVC JIS Symbol LVA OUT LVH IN LVD N.O.
Station L1 L2 2 33.5 27.5 11 128 122 12 13 149 143 14 15 170 164 16 17 191 185 18 19 212 206 3 44 38 20 4 54.5 48.5 5 65 59 6 75.5 69.5 7 86 80 8 96.5 90.5 9 107 101 10 117.5 138.5 159.5 180.5 201.5 222.5 111.5 132.5 153.5 174.5 195.5 216.5 2.1-14 Series SY Made to Order (Contact SMC for further specifications, dimensions and delivery lead time.)
R E E B A H 2-P Port size 2-P A 2-M Thread depth N B H Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G1/2 E B A H D 2-P Port size (S) 2-M Thread depth N L K (mm) Electrical entry P Port size Model Grommet: G Conduit: C Conduit terminal: T M L K H F E D C B N A U S R Q R Q R Q M4 12.8 14 28 12.5 6.5 31 64 28 4.5 13.5 83 66 50 99 50 44 59 22 1/8 VCB21 M4 12.8 18
01 ( ) 1 8 02 ( ) 02 ( ) VXA223l VXA224l VXA225l VXA226l VX070-022 1 4 1 4 03 ( ) 3 8 04 ( ) 1 2 VX070-029 Ordering Example (Example) Series VXA21, Orifice size 4.5mm, Normal closed, Rc(PT)1/4 (Part number)VXA2130-02 4.1-59 VXA21/22 Dimensions (Orifice size 3 mm, 4.5 mm, 6 mm) VXA212m, VXA213m, VXA223m, VXA224m Model Port size P Rc(PT) A B C D E F With bracket G H I J VXA21 VXA22 , , 18
ZF ZFA100 Port size Symbol Model A B 18 20 28 ZFA200 1 8 1 4 ZP Manifold ZCU AMJ Misc.
ZU Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 18 ZL ZY ZQ (mm) Model A 40 ZPT40H-B8 C M8 x 1.25 40 ZPT40H-B10 42 M10 x 1.5 B 42 ZF (mm) B 42 50 ZPT50H-A14 52 Model A 40 ZPT40H-A14 ZP 50 ZPT50H-B8 52 M8 x 1.25 50 ZPT50H-B10 52 M10 x 1.5 ZCU AMJ 63 80 ZPT H-B
Addilionally, reter lo the page 18 tor the set pressure lange by units of slandard measured pressure Additionally, reler lo page 18 as maximum set pressure differs on unit ol standard measure. Note 2) 2-wirc type 4 to 20 mA is not available. Power supply voltage (24 VDC or '12 lo 15 VDC) is rcquired Note 3) Selecl either analog oulpul or swtch outpul.
pa9e 4 & 5 Product Variations .pa9e 6 & 7 Specifications/Construction/Parts List .page B Selection Chart & Duty Ratio .page 9 Kinetic Moment Allowance &Table Deflection ,.page 10 Criteria of Accelerating Speed . .page 11 How To Order. .pages 12 & 13 How to Mount .Page 14 Dimensions. ."...pa9es 15 & 16 Specifications/Construction/Parts List . ...page 17 Selection Chart & Duty Ratio ..,.page 18
InoluO3 OoOy and C) locklng pln3 I xTol9 xT1{13.4 3 I xmiGtS xT106-5 AFPSI6E{18 ARPt6&119 1 Soool A Sb're A6'y. 6 1 Spacer xr019192 xr@l.r2 Gaskst-Solgnold Covor xTo133't-2 NXTO3OS 1 Covr a$mbly-Ac. solonold. Can3isls of covr, rcBsd non.locklng filanuel oosralor ard {4) 6tall 1A E Coyr BBmbly-A.C. soloold, wltnod msnual opdEtor, and with op.at'.. rbuntlno hol6 oluood.
PB 0103 1 5 Gasket Subplate Buna N AXT 33112-2 18 Screws Pilot Cover (4) AXT 334.1G1 B o E G H K il N 127) 0.63 (161 1.42 {36) 0,91 123) 0.al (15.5) 1.24 (32) 6.10 (155) 2.4e (63) (62) 2.O5 <52) ?.o1 (51) l2B 1.06 1 7 Hold Down 8olls {8.32 x 1 9'61(2) NXT 333,17.5 Mi(tne ln Parenlhess NVSA45l4 DETAIL REF. 0EscRrPTtol{ MATERIAL PAB' NO. 1 Body Alum.
2.92 MECHANICAL VALVES SERIES (N)VM800 3/2 MECHANICAL VALVE 18 (N)VM800 SERIES 32 Normally Open or Normally Closed Valve A Variety Of Actuator Types Available Robust Design T E C H N I C A L SPECIFICATIONS Fluid Air Operating Pressure 0 ~ 9.9 Bar / 0 ~ 144PSI Ambient and Fluid Temperature 5 ~ 60C / 41 ~ 140F Effective Orifice (Cv Ffactor) 6mm2(0.33) Recommended Lubricant Turbine Oil #1 (ISO
#1 #2 #3 4 3 4 3 4 Product image/Pin assignment 1 3 1 2 1 2 Plug Plug Plug Number of functional poles M8: 3 poles M12: 4 poles Key type A-coded (Normal key) Cable O.D. 3.0 to 5.0 mm 3.5 to 6.0 mm 4.0 to 8.0 mm Applicable cable Wiring1 Wire gauge (Stranded wire cross section) 0.14 to 0.25 mm2/AWG26 to 24 0.25 to 0.34 mm2/AWG24 to 22 0.14 to 0.34 mm2/AWG26 to 22 0.34 to 0.75 mm2/AWG22 to 18
1 q t i 385 PF2D Series Dimensions: Remote Type Sensor Unit PF2D504-11/520-13 60 70 176 40 15 A Model PF2D504 PF2D520 9.52 12.7 62 52 42 A 4 x 4.5 52 1 18 PF2D540-19 Internal Circuits and Wiring Examples 78 86 186 -1/2 Analog voltage output Analog current output 56 15 Sensor Monitor PF2D3 Black Output for PF2D3 4 8 Switch output Main circuit Main circuit Main circuit Main circuit 3 7 U DC
13.6 PFMC7202 Rc3/4, NPT3/4, G3/4 90 35 66.1 46.7 17.5 24 31 28 16.8 PFMC7501/7102 G1/2 76 30 60.6 41.2 15 14 26 18 13.6 Symbol Model Bracket dimensions S T U V W PFMC7501/7102 24 22 32 40 50 PFMC7202 30 30 42 48 58 Lead wire and M8 connector ZS-40-A Cable Specifications 2 (White) (Black) 4 4 Conductor Nominal cross section AWG23 10 (Blue) 3 1 (Brown) Outside diameter Approx. 0.7 mm (15)
Item CH2 measured value: 16-bit signed integer Bit offset 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 Item CH32 measured value: 16-bit signed integer Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Item CH4 measured value: 16-bit signed integer Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Error diagnosis CH4 diagnosis CH3 diagnosis CH2 diagnosis CH1 diagnosis Reservation
A Applicable absorber B SR Dimensions RBC08C RBC10C RBC14C RBC20C RBC27C RJ08U 6.5 6.8 6 RJ10U 9 8.7 7.5 X RJ14U 12.5 12 10 16 18 20 RJ2015U 21 25 25 RJ2725U H B T 2 x D MM L Part no.
Especially, rust may be generated in an environment where water drops are likely to adhere due to condensation etc. 18 These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.