Also, do not use the cylinder with fixed at external slider to avoid excessive moment applied to bearing of the cylinder. And, if the cylinder is mounted with axial compressing force applied, the cylinder tube is deflected and operating failure may be caused.
Do not service machinery/equipment or attempt to remove component until safety is confirmed. 1) Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 3-12-6
Do not allow repeated bending or stretching forces to be applied to lead wires. Wiring arrangements in which repeated bending stress or stretching force is applied to the lead wires can cause broken wires. 1. Do not drop or bump. Do not drop, bump or apply excessive impact (1,000m/s) when handling.
To mount ghl angle lype, be cedain 10 check that no possible ntefence occurs.
Do not allow repeated bending or stretching forces to be applied to lead wires. Wiring arrangements in which repeated bending stress or stretching force is applied to the lead wires can cause broken wires. 1. Do not drop or bump. Do not drop, bump or apply excessive impact (1,000m/s) when handling.
As the connected actuator will start operating due to this manual operation, be sure to confirm that it is safe to do so beforehand. Ex. 1) Cable length: 300 mm DXT1215T-5W1U-01m(-X1) Symbol for electrical entry MNon-locking push type Push the manual override button all the way down. 2.
) 10% or less (With power supply polarity protection) 55 mA or less (at no load) NPN or PNP open collector output: 1 output 80 mA 30 V (With NPN output) 1 V or less (With load current of 80 mA) 1 s (0.25, 0.5, 2, 3) Yes 1% F.S.
10% or less (With power supply polarity protection) 55 mA or less (at no load) NPN or PNP open collector output: 1 output 80 mA 30 V (With NPN output) 1 V or less (With load current of 80 mA) 1 s (0.25, 0.5, 2, 3) Yes 1% F.S.
Do not use it for mounting. Otherwise, the adjustment at shipment may deviate. 792
e 00 10 20 30 40 50 60 70 80 90 100 110 Vacuum pressure 50 kPa (qwe) = Suction flow (Q1) 31 l/min (ANR).
If the installation is using accurate control, wait until the product has warmed up (approximately 10 to 15 minutes).
Verify the specifications before use. x100 Node ID 10 1 Specifications Assembly and disassembly of the SI unit DIP SW 5 5 5 Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.
Do nol loosen the recessed head screw on the top of the sensitivity adiusting screw because ii is lor prelenting the screw trom slipping otf. @
If operating pressure is over the range then cylinder will be damaged and injury by broken pieces. (4) Do not put your hand into the slit of the body without confirming safety. Injury and Bodily harm will occur with the valve operated when valve is operated valve. (5) Do not remove the Cover Fig.1 29 on the actuating part.
Do not apply excessive force or impact. This will not only damage the product but also decrease its performance and life expectancy. It is not possible to disassemble the bonnet assembly of this product. If the components and assembly are damaged, or damage is expected, exchange the bonnet assembly itself. Do not disassemble the parts that are not explained in this operation manual.
Do not install by directly grasping the cylinder tube, as this could cause a tube to deform and malfunction. 2. Do not install it by directly grasping the piston rod with a pair of electricians pliers. Scratches on the piston rod would cause a bearing or rod seal to get damaged, malfunction, and leak air. 10 12.4 4 15 12.8 20 13.2 16
(inch) Connection thread Model 5 32 1 4 5 16 " " " " 3 8 Male connector KSH 10-32 UNF KQ2 1 8 NPT KQB2 NPT 1 4 KS KX KS KX NPT 3 8 KM Male elbow KSL 10-32 UNF KF NPT 1 8 M NPT 1 4 H/DL L/LL NPT 3 8 KC KK Precautions KK130 Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 13 to 17 for Fittings and Tubing Precautions.
Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. During the zero clear operation, pressure above 10%F.S. has been applied. After 3 s, the mode will reset to the measurement mode. The zero clear range can vary 1 digit with individual product differences.
Function Setting Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Mounting screw Function selection mode Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not remove it and attention should be taken not to deform nor gouge. 14 Other Cautions for Operation 7-1) Environment The piston slider has iron part inside. Keep the cylinder tube away from the water. Do not use in atmosphere or place where might corrode the cylinder. Protect the cylinder with cover where it is exposed to dust and particle, drop of water/oil.