Precautions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate or set with wet hands. This may lead to an electric shock. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate or set with wet hands. This may lead to an electric shock. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
Do not use the monitor in a place where temperature suddenly changes even if it stays within the specified range. Do not expose the monitor to heat radiation from a heat source located nearby. It can cause malfunction. Adjustment and Operation Do not short-circuit the load. The monitor indicates the error status when a load is short-circuited.
Do not use in a place where water, oil or chemicals splashes. Otherwise it can cause failure or malfunction. Do not use the Pressure switch nearby a place where electric surges are generated.
They do not guarantee an actual fixed range (expect approximately 30% dispersion).
Do not drop or bump. Do not drop, bump or apply excessive impacts (300m/s or more for reed switches and 1000m/s or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.
Hold/Release success: default output DO[101] Hold/Release failure: default output DO[102] * Digital output port can be selected within DO[101] to DO[112] * you select the same digital output port for different status signals, a warning message will be displayed. 2. Test run The manual operation of the magnet gripper unit can be checked.
Warning (1) Do not use in an environment where corrosive gases, chemicals, sea water, water or steam are present. (2) If using in a location directly exposed to sunlight, shade the product from the sunlight. (3) Do not mount the product in locations where it is exposed to radiant heat. (4) Do not use the product in a place where static electricity is a problem.
Do not expose the product to direct sunlight for an extended period of time. 3. Do not use in a place subject to heavy vibrations and/or shocks. 4. Do not mount the product in locations where it is exposed to radiant heat.
Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not apply excessive lateral load to the piston rod.
Do not use a cable longer than 100 m. For long wire lengths, we recommend a ferrite core should be attached to both ends of the cable, to reduce noise. (2) Do not use a load which generates a surge voltage.
Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not use in direct sunlight. 10. Do not mount the product in locations where it is exposed to radiant heat. 11. Take appropriate measures against the lightning surge on the equipment side as the auto switches do not have any lightning surge resistance specified in the CE/UKCA marking. 12. Do not use in environments subject to radiation stress.
Do not torque it more than required in case to operate a lock type manual.
Do not use in environments where there is a danger of corrosion. 2. Do not use in direct sunlight. 3. Do not operate in a location subject to vibration or impact. 4. When using auto switches do not operate in an environment with strong magnetic fields. 5. Grease base oil can decrease depending on external environment and operating conditions.
Do not drop or bump. 5. Do not allow short circuit of loads.
Do not drop or bump. Do not drop, bump or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.
M5 11.5 1/8 34 (8) Do not use this product in such a way that Body A rotates at any time. Also, do not use it in such a way that moment loads act on it. Body A or the joint may be damaged.