Size: 4 (40), Body Material: C (Brass), Seal Material: F (FKM), Port Size: 04 (1/2), Thread Type: N (NPT), Rated Voltage: 3 [120 (110) VAC], Electrical Entry: DN (DIN Terminal w/o Connector, w/Surge Voltage Suppressor)
Size: 4 (40), Body Material: S (Stainless Steel), Seal Material: E (EPDM), Port Size: 04 (1/2), Thread Type: F (G), Rated Voltage: 3 [120 (110) VAC], Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor)
Size: 4 (40), Body Material: S (Stainless Steel), Seal Material: E (EPDM), Port Size: 04 (1/2), Thread Type: N (NPT), Rated Voltage: 3 [120 (110) VAC], Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor)
Size: 5 (50), Body Material: C (Brass), Seal Material: F (FKM), Port Size: 06 (3/4), Thread Type: N (NPT), Rated Voltage: 3 [120 (110) VAC], Electrical Entry: DN (DIN Terminal w/o Connector, w/Surge Voltage Suppressor)
Size: 5 (50), Body Material: S (Stainless Steel), Seal Material: N (NBR), Port Size: 06 (3/4), Thread Type: N (NPT), Rated Voltage: 3 [120 (110) VAC], Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor)
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series]
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specification: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series]
Voltage: 3 (110 to 120 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flush, Thread: N (NPT), Solenoid: D (Double Solenoid)
Voltage: 3 (110 to 120 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flush, Thread: F (G), Solenoid: D (Double Solenoid)
Voltage: 3 (110 to 120 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flush, Thread: Rc (PT), Solenoid: D (Double Solenoid)
Voltage: 3 (110 to 120 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Type, Flush, Thread: F (G), Solenoid: Single Solenoid, CE Marking: Q (CE Marked Product)
Function: 2 (2 Position, Double), Model: 0 (Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor)
Function: 1 (2 Position, Single), Model: 0 (Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: E (Grommet Terminal), Surge Suppressor: None, Port Size: 10 (1), Thread: N (NPT)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: None, Port Size: 10 (1), Thread: N (NPT)
Function: 1 (2 Position, Single), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: None, Port Size: 06 (3/4), Thread: N (NPT)
Function: 3 (3 Position Closed Center), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: None, Port Size: 10 (1), Thread: N (NPT)
Function: 1 (2 Position, Single), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: None, Port Size: 06 (3/4), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: None, Port Size: 10 (1), Thread: T (NPTF)
Solenoid: 1 (Single Solenoid), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Electrical Entry: DO (DIN Terminal w/o Connector), Light/Surge Voltage Suppressor: None, Manual Override/Classification: B (Locking Slotted Style-Tool Required), Thread: N (NPT)