100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Nil A B Non-locking push type Non-locking extended type Locking slotted type 1 2 3 4 5 6 7 9 1 2 3 4 5 6 7 9 Electrical entry Grommet Conduit Conduit terminal DIN terminal DIN terminal with indicator light Option G C T Note) D DL Option Option Option Note) When the electrical entry
Specifications Model MGP-Z MGP-AZ Basic type With air cushion Action Double acting Fluid Air Proof pressure 1.5MPa Maximum operating pressure 1.0MPa Minimum operating pressure 12, 16 0.12MPa 16 0.15MPa 20 to 100 0.1MPa 20 to 100 0.12MPa Ambient and fluid temperature -10 to 60 (No freezing 12 to 63 50 to 500mm/s 16 to 63 50 to 500mm/s Piston speed 80, 100 50 to 400mm/s 80, 100 50
L L H Holding point Holding point H MHF2-12D MHF2-8D 80 50 Pressure 0.2MPa 40 60 0.5MPa 0.5MPa Pressure 0.2MPa 0.6MPa 0.6MPa Overhang Hmm Overhang Hmm 0.7MPa 30 0.7MPa 0.3MPa 0.3MPa 40 0.4MPa 0.4MPa 20 20 10 40 20 80 60 40 20 0 0 50 30 10 Gripping point L mm Gripping point L mm MHF2-20D MHF2-16D 100 0.5MPa 100 Pressure 0.2MPa Pressure 0.2MPa 80 0.5MPa 0.6MPa 80 0.6MPa Overhang Hmm Overhang
Coil rated voltage (V) 24, 6, 12, 48 Allowable voltage fluctuation (%) Power consumption (W) [Current mA] 15 to +10% of rated voltage 1.8 (With indicator light 2.1) [24 VDC: 75 (With indicator light 87.5)] Note) DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Inrush Note) Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200
S, Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% Operating pressure (MPa) Bore size (mm) 0.3 Operating direction 0.5 0.7 181 IN 302 422 32 241 OUT 402 563 Standard Stroke 317 IN 528 739 40 (mm) Bore size (mm) Standard stroke 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 377 OUT 628 880 IN 495 825 1150 32 1 50 OUT 589 982 1370 40 50 2 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15,
Default settings Function Default settings Page [rEF] Reference condition [Anr] Standard condition [F 0] [rEF] page 29 [Uni] Unit selection function 1 [ L] L/min [oU1] Output mode of OUT1 [HYS] Hysteresis mode [1ot] Switch operation of OUT1 [1_P] Normal output [P_1] Set value of OUT1 [100] 100 L/min [F 1] [oU1] page 31 [H_1] Hysteresis of OUT1 [ 10] 10 L/min [CoL] Display colour of OUT1
, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C.
CVS1K 40, 50 63, 80 100 J Standard 10-15-67 Double acting DNonrotating rod 40, 50 63 10-15-78 -X Series MVGQ 2012, 16 20, 25 32, 40 50, 63 80, 100 Data 10-16-1 Double acting 10-15-1 Series CV Valve Mounted Cylinder Precautions Be sure to read before handling.
CVS1K 40, 50 63, 80 100 J Standard 10-15-67 Double acting DNonrotating rod 40, 50 63 10-15-78 -X Series MVGQ 2012, 16 20, 25 32, 40 50, 63 80, 100 Data 10-16-1 Double acting 10-15-1 Series CV Valve Mounted Cylinder Precautions Be sure to read before handling.
Item Decimal Common Format "Data-INT" "Data-SINT" Input 100 100 Output 150 150 Configuration 130 130 (5) Size: Perform setting as shown below.
32 37.8 43 50 90 100 110 122 1.08 1.09 1.00 1.00 1.00 1.04 1.04 SF 0.82 0.83 1.00 1.07 0.66 0.46 0.98 1.09 SFD 1.13 1.18 LLB 1.22 1.24 AD GD Data D: Air Flow Capacity Air flow capacity SCFM (m3/h (ANR)) Model IDFB11E IDFB3E IDFB4E IDFB6E IDFB8E IDFB15E IDFB22E IDFB37E IDFB75E IDFB55E 37F (2.8C) 10 (17) 15 (25) 25 (43) 41 (70) 59 (100) 71 (120) 107 (182) 161 (273) 226 (384) 300 (510) Outlet
Table 8-1 Quality standard for fresh water (tap water) Item Product Standard value For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Sulfuric acid ion [mg/L] 50 or less 200 or less Standard item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness
PF2A30 series PF2A31 series 1 to 10 L/min type (PF2A510) 5 to 50 L/min type (PF2A550) [11L]: [21L]: [51L]: 10 to 100 L/min type (PF2A511) 20 to 200 L/min type (PF2A521) 50 to 500 L/min type (PF2A551) [10L]: [50L]: PF2W30 series PF2W33 series [11L]: 10 to 100 L/min type (PF2W511) 0.5 to 4 L/min type (PF2W504) [04L]: [20L]: [40L]: 2 to 16 L/min type (PF2W520) 5 to 40 L/min type (PF2W540) PF2D30
) 114 VXA 53 VN 43 63 LVC LVA LVH LVD LQ-GM LQ-GL LVQ LQ 50 LVN 50 207 85 TI/ TIL 342 85 LQ-GL 40 28 PA SET POS. 40 28 LQ-GM 4-R3 SET POS. 6 6 4-R3 6 6 PAX 4-R3 4-R3 (Max. 91) 325 PB (Max. 91) 191 87 60 87 60 112 112 17-5-37 35 Series LV Fitting Assembly Procedure Assemble fittings following the procedure shown below.
H4 Initial power / 100 VAC 200/40 200/50 400/100 600/150 Power Symbol 200 VAC 800/40 800/50 1600/100 2400/150 consumption (W) Heater assembly number XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-2 XL1A25-60S-3 XL1A25-60S-2 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs.
(ANR)] Consumption flow rate [L/min (ANR)] 250 100 160 ZP3 200 80 120/150 120 150 60 ZP3E 40/60/80 80 100 40 ZP2 40 50 20 ZP2V 0 0 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 Supply pressure (MPa) 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 Supply pressure (MPa) 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 Supply pressure (MPa) ZP ZPT ZPR XT661 XT661 739 XT661 Series Lifting ForceDistance
Bore size Cylinder stroke (mm) Refer to the standard stroke table on page 265. 20 25 32 40 50 63 80 100 20 mm 25 mm 32 mm 40 mm 50 mm 63 mm 80 mm 100 mm Port thread type Built-in Magnet Cylinder Model Nil Rc NPT If a built-in magnet cylinder without auto switch is required, there is no need to enter the symbol for the auto switch.
ISO Standard Hydraulic Cylinder 40, 50, 63, 80, 100 CHSD Series 10 MPa CHQ How to Order CHK 100 M9BW CH D SD B 40 CHN Magnet for auto switch Number of auto switches Series type CHM Nil D Without Nil S n 2 pcs. Built-in Symbol D Nominal pressure CHS CHS 1 pc. 10 MPa "n" pcs.
75 100 125 150 175 200 250 300 Reed switches: D-Z7, Z8 Solid state switches: D-Y5, Y6, Y7 Female threads Male threads 180 Single rod Double acting CQ2 200 Double rod New 180 and 200 Compact cylinder variations A wide range of 15 sizes from 12 to 200 Bore size (mm) Compact cylinder series 12 16 20 25 32 40 50 63 80 100 125 140 160 180 200 CQ2 Large bore CQ2 CQS Refer to N320 "CQ2" and CAT.E256
Refer to back page 50 for Safety Instructions and pages 6 to 8 for Air Preparation Equipment Precautions. Air Piping Compressor Air Delivery Caution Caution HAA HAW IDFA55E, 75E Compressed air inlet Compressed air outlet Use an air compressor with an air delivery of 100 L/min or larger with the IDFA3E to 75E series.