C, prevent water droplets from entering the inlet port. (No freezing of the fluid) * Note 2. ANR indicates the flow rate converted to the value at 20 deg. C, under the atmospheric pressure and the state of relative humidity 65%. * Note 3.
Body Assembly B Manifold mounting parts IZN10 ES 2 10 A002 01 06 Number of manifold Mounting pitch ES 17mm 2 2 stations 3 3 stations 4 4 stations Nozzle shape NIL 01 02 11 Piping female Note 1) Rc1/8 Large flow nozzle Type Energy saving charge elimination nozzle Electrode needle cleaning kit/IZS30-M2 Piping diameter 06 f6: metric 07 f6.351/4"): inch 16 f6: metric (elbow) 17 f6.351/4"): inch
Confirm there is air leakage. 1-2) Caught gasket Replace with new gasket. 1-3) Intrusion of foreign matter To remove foreign matter by air blow of piping and when a gasket damaged, replace with new gasket. 2. Air leaks through One-touch fitting 2-1) Tube is not inserted enough deeply. 2-2) Tube has a flaw. 2-3) Tube is cut diagonally.
Self-diagnosis: 5% F.S. or less Linearity 1% F.S. or less Hysteresis 1% F.S. or less Repeatability 1% F.S. or less Sensitivity 1% F.S. or less Temperature characteristics 0.12% F.S. or less/C Output pressure display Accuracy 2% F.S. or less 1 digit 2 Output pressure [MPa] This range is outside of the control (output). 0.2 MPa Minimum unit Note 4) MPa: 0.01, kgf/cm2: 0.1, bar: 0.1, psi: 1
11.5 Width across flats 14 With end lock 3 119.5 + Stroke 137.5 + Stroke Basic type With end lock Accessories SMTS20, #1 (#1 + #2) SMTS20, #2 (#2 + #4) SMTS20, #3 7 Precision Cylinder Series MTS Dimensions/25 MTS25 Basic type 12 10 53.5 51.5 2-cushion needle Width across flats 11 7.5 6 Rod cross section 7 6 2-M5 x 0.8 (port size) 28 0.2 16.5 15 M6 x 1.0 4.5 4-4.5 through 2 x 4-7.5, counter
Furthermore, when mounting supply/exhaust block assemblies on both sides of type B with a 2 to 10 station manifold, calculate the weight W using the formula for 11 to 16 stations.
6 t Zinc chromated w Electroless nickel plated Black zinc chromated Accessory Accessory IN 2 Series ARJ310 Dimensions ARJ310-01 ARJ310F-01 Approx. 31 Approx. 56 Approx. 56 Approx. 35 32 22 M12 x 1 Panel fitting dimensions 12.5/Panel thickness: 4 or less Approx. 27 19 2 2 -5.5 Approx. 57.2 8.5 Approx. 82.5 15 Applicable tube O.D. 4, 6, 5/32, 1/4 Port size Rc, NPT 1/8 2 2 1 1 Pressure gauge
Table of contents P 1 2. How to order P 2 3. Specifications P 2 4. External dimensions drawing P 3,4 5. How to mount a nozzle P 5,6 6. Safety Instructions P 710 -1- 2. How to Order IBG1 0 02 Adjuster Symbol Type 0 Without adjuster 1 With adjuster Supply port Nozzle (Refer to page 4 for details.)
OUT2 setting/(CH1 only) MPa or kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE Normally Open Normally Closed SET SET 16-3-11 11 Series PSE530/200 Operation 1: Initial Setting 4 Response time setting MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE 5 ms 20 ms 160 ms 640 ms SET Press SET button.
Sensor connector port 4 3 2 1 Power supply/Output connector 2. Connecting power supply/output connection cable To connect the power supply/output connection cable to the controller, insert the cable connector with the C part facing down until it clicks. C 2m 21 Series PSE Specific Product Precautions 3 Be sure to read before handling.
Non-locking push type Slotted locking type, Knob locking type Note 2) Manual override 2 to 10 stations: W = 26n + 172 11 to 16 stations: W = 26n + 199 2 to 10 stations: W = 54n + 227 11 to 16 stations: W = 54n + 264 Note 3) SY3000 Weight W (g) n: Stations (D-sub connector) Main valve/pilot valve common exhaust type Internal pilot External pilot Pilot exhaust type Pilot valve individual exhaust
3 Port Air Operated Valve Series VZA200/400 Fluid Air 1 2 1 2 VZA4 2, 4 4 1 2 1 2 VZA2 2, 2 4 1 2 1 2 VZA4 2, 4 4 1 2 1 2 Operating pressure range (MPa) 0.1 to 1.0 0.15 to 1.0 VZA2 2, 2 4 0.1 to 1.0 0.15 to 1.0 Pilot pressure range (MPa) Impact/Vibration resistance (m/s2) Note) 150/50 Operating pressure Pilot pressure Note) Impact resistance: No malfunction from test using drop impact tester
Brown Brown Load Load Switch 1 Switch 1 Blue Blue Brown Brown Switch 2 Switch 2 Blue Blue Leakage current Load Impendance x 2 pcs. x Power supply voltage Residual voltage x 2 pcs.
Left Right 1 2 1 2 1 2 Left Right 1 2 1 2 1 2 ZSE30 ISE30 ZSE40 ISE40 MPa MPa MPa MPa MPa MPa ZSE10 ISE10 ISE70 With n stations, the bracket is mounted on the first and n th sensor from the left. ZSE80 ISE80 1 2 n 1 2 n ZSE ISE ZSP PS MPa MPa MPa ISA2 ISA2 PSE Addition of Manifold Stations IS 1. Loosen the screws and remove the 2 mounting brackets on the front and back side. 2.
M2 M3 m2 m3 m4 10 15 25 1 2 1 2 2 2 1.4 CY1F 1.5 3 1.5 5 5 5 2 14 20 14 12 12 12 12 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.
Outlet pressure (MPa) Outlet pressure (MPa) Set point Set point Flow rate (L/min (ANR)) Inlet pressure (MPa) 688 Regulator with Mist Separator AMR3000 to 6000 Series Dimensions AMR4000/5000/6000 M N H ARJ E AR425 to 935 G D ARX F 2 x V 2 x V AMR AMR AMR3000 R A Compact pressure switch ARM (Option) S Bracket ARP Adapter assembly (Option) T IR-A B J B L P C K PT elbow IR 2 x U IRV VEX SRH SRP
R 1/2 R 3/4 R 11/4 R 2 R 1 Accessory (2) Rc 1/2 Valve for drainage (1 pc.) Pressure gauge (1 pc.) R 3/8 x 100 M16 x l 250 M16 x l 300 M24 x l 500 M16 x l 500 Anchor bolt (4 pcs.) Note 1) Manufactured upon receipt of order Note 2) The accessories should be mounted by user.
Fittings & Tubing Air Cylinders Rotary Actuators Bracket (Option) Bracket (Option) R R V Q V Q IN OUT B C IN OUT Clearance for maintenance G B C 2 x P (Port size) 2 x P (Port size) Hexagon width across flats 14 1/8 Drain Hexagon width across flats 17 1/4 E A Clearance for maintenance G Drain A AF50/60-A 1021J D M U S N T Bracket (Option) R V Q C B IN OUT 2 x P (Port size) Hexagon width across
Body Needle V seal Lock nut Adjustment handle Insert bushing Nut Collar A 1 2 3 4 5 6 7 8 PFA PCTFE PTFE PVDF PVDF PFA PFA PFA Body class 2 y u y u B Dimensions A (B) (max.S) D H Port A 2 x G SMC (J) SMC C E F K Port B E A B C D E F G H J K S Model 48 60 72 LVN20 LVN30 LVN40 24 30 36 12 18 22 88 110 124 34.5 43 52 6 9 11 4 5 6 14 25 25 20 26 33 18 24 30 2.4 7.5 8.0 940 LQ1/LQ3/LVN/LQHB Series
SMC CORPORATION Contents Chapter 1: Read Before Use 1 Chapter 2: Product Summary 5 2-1. System Configuration 5 2-2. How to Order 5 2-2-1. Precision MONOSASHI-KUN 5 2-2-2. Applicable Auto-Switch Models 5 2-2-3. Options 6 2-3. Precautions on Selection 6 Chapter 3: Specifications 3-1. Cylinder Specifications 7 3-2. Sensor Specifications 7 Chapter 4: Wiring 4-1.