Return 0.5 0.4 0.2 0 0 Out -0.2 -0.4 -0.5 -0.6 -0.8 0 25 50 75 -1 1 2 3 4 -1 100 5 Input signal % F.S.
The AREA 1 and AREA 2 in the setting items define this output range. The input condition is that the AREA 1 and AREA 2 should be both in the actuators operating range, and AREA 1 < AREA 2. < [B] In position> This is the condition that turns on the [INP] (in position) output signal.
N L1 L2 Weight (g) Port B Min. port size L3 L4 L5 L6 P Q1 Q2 M KM12-03-35-10 KM12-03-35-6 6 87 10 40 67 5 32 1 4 18 29.5 19.5 29 10.6 12 16 6 17.46 10 110 6 95 10 121 6 102 10 61.5 75 KM12-07-35-10 KM12-07-35-6 48 84 10 19.5 31.5 21.5 31.25 13 7 13.2 17 17.46 1 4 1 4 73.5 96 KM12-09-36-10 KM12-09-36-6 52.8 100 12.7 37.5 23.7 37.7 25 15 9.5 15.2 18.5 5 16 3 8 22.22 83 117 132 Metric Thread
1 Specifications 6 1 IDX-OM-X004 Heatless Air Dryer 6 References 6-2 Externals dimensional drawing Tube Size related to installation Bracket connection Model A B C D E Part No.
69 M4 x 0.7 6 4.5 67 M5 x 0.8 25 60 105 48 45 23 13 18 69 32 17 2.5 118 CYP32 8.6 115 M6 x 1 8 7.5 90 Rc 1/8 50 100 138 87 79.5 29 17 22 115 46 27 3.5 155 Note 1) These dimension drawings indicate the case of piping port position "Nil".
Option Part no. 1 Bracket A ZS24A With 2 pcs. of mounting screws 1 Bracket D ZS24D With 2 pcs. of mounting screws 1 Panel mount ZS24E 1 ZS24F Panel mount + Front protection cover 1 For General Fluids High Precision Digital Pressure Switch Series ZSE50F/ISE50 Specifications ZSE50F (Compound pressure) 100 to 100kPa 100 to 100kPa 500kPa 0.1 0.001 0.001 0.02 1 0.1 ISE50 (Positive pressure)
Model Selection 1 Obtain the correction factor for the temperature from data A or B and the correction factor for the air pressure from data C. Temperature Data A or B = Series IDUS: Data A Series IDFS: Data B Air pressure Data C = 3 2 Calculate corrected air flow by using A or B and C.
When 1 digit = 1 kPa, the pressure is given with an increment Digit (Min. setting unit) of 1 kPa, e.g., 1, 2, 3,, 99, 100. E Energy saving automatic control Indicate that the vacuum pressure during adsorption is monitored and ON and OFF of the ejector is automatically controlled.
0 e New PFA q Body New PFA w Sensor Super PFA e Tube PPS r Housing A PPS t Housing B PPS y Housing C POM u Bushing PPS i Cap FKM o Gasket FKM !0 O-ring Stainless steel 304 !1 Thread PVC !2 Lead wire !1 q t i PF2D540 o !0 u !0 !2ywr e !
L1 L2 XMD-25 50 123 48 1 40 26 41 16 7.5 XMD-40 65 170 66 2 55 70 41 63 20 15 P.C.D 58.7 6x6.6 XMD-50 70 183 79 2 75 52 68 20 17.5 XMD-63 88 217 100 3 87 95 114 70 72 20 19.5 P.C.D 92.1 8x 8.4 XMD-80 90 256 117 3 114 110 83 98 20 26.5 D G C C K J H B Fd (K Flange) 45 Fn (KF Flange) A E Unit: mm Model A B C D E Fn Fd G H J K XYD-25 100.2 86.7 48 1 23.5 40 26 66 16 7.5 XYD-40 130 114 66 2 38
Note 2) The wiring specification is positive common only. 1 Series VV061 Unit Manifold Specifications Fluid Air Operating pressure range (MPa) Standard 0 to 0.7 High flow type 0 to 0.3 1(P) port 3(R) port Vacuum specification (MPa) Standard 100 kPa to 0.6 100 kPa to 0 High flow type 100 kPa to 0.2 100 kPa to 0 Ambient and fluid temperature (C) 10 to 50 (No freezing) Response speed (ms) Note
Fig. a Fig. b Double Single Double Double Double Single Double Double 1 No. 0 2 4 6 Side A No. 5 Side A 0 2 3 Input block SI unit Tie-rod (2 pcs.) accessory 3 4 Station Station 1 2 3 4 1 2 3 4 7 2 No. 1 3 5 7 Side B No. 1 4 6 Side B Bus cable and termination resistors The cables, connectors, and termination resistors used in CANopen networks shall meet the requirements defined in ISO 11898
Node address SW1 SW2 SW3 SW4 Node address SW1 SW2 SW3 SW4 0 0 0 0 0 8 0 0 0 1 1 1 0 0 0 9 1 0 0 1 2 0 1 0 0 10 0 1 0 1 3 1 1 0 0 11 1 1 0 1 4 0 0 1 0 12 0 0 1 1 5 1 0 1 0 13 1 0 1 1 6 0 1 1 0 14 0 1 1 1 7 1 1 1 0 15 1 1 1 1 0: OFF 1: ON Set the node address so that it does not duplicate the node address of other slaves.
Setting using System Manager 1. Copy the XML file *1 for this unit to the following folder: C:TwinCATloEtherCAT (this path is valid only when the default setting is kept.) Start up the TwinCAT System Manager after copying. 1: The XML file for this product can be found on the SMC website (URL http://www.smcworld.com). 2. Network setting 2-1. Off-line manual configuration method 2-1-1.
370 440 100 120 130 160 180 210 246 290 ITVX 1 4, 3 8, 1 2 1 4, 3 8, 1 2 1 2, 3 4 1 2, 3 4 PVQ 3 4, 1 3 4, 1 VY1 Adapter Assembly Installation Procedure Accessory/Compact Pressure Switch: IS10-01 For details, refer to Best Pneumatics No. 8.
s b l t h g i e W ) 7 . 0 ( 4 5 . 1 ) 1 . 1 ( 3 4 . 2 ) 5 . 2 ( 1 5 . 5 ) 5 . 4 ( 2 9 . 9 t e k c a r B P 4 2 B P 5 2 B e g u a G 5 2 O R A N . d t S ) g i s p 0 6 1 ~ 0 ( n o i t p O K50A-MP1.0-N02M K50A-MP2.0-N02M 5 3 O R A N . d t S ) g i s p 0 3 ~ 0 ( How To Order N R NAR 4 25 02 B Body size Option 4 1/2 6 1 8 11/2 9 2 Nil None R IN-OUT Reversal (RightLeft) Pressure regulating range
(mm) (Nm) 6 7.3 0.02 100 10 6.0 0.05 100 15 4.5 0.15 200 20 3.7 0.20 300 25 3.7 0.25 300 32 3.1 0.40 400 Fig.6-2 Non-rotation accuracy direction 40 2.8 0.62 400 50 2.4 1.00 500 63 2.2 1.37 500 Note 1) Avoid usage where max. allowable moment is exceeded. In that case, use external guide together.
When 1 digit = 1 kPa, the pressure is given with an increment of 1 kPa, e.g., 1, 2, 3, , 99, 100. Digit (Min. setting unit) E One of the switch output types, and means the operation in which a switch is turned on when pressure equal to the switch output set value or less is detected.
Example wiring is shown in the figure b. : Bit status 0 and 1 in the data corresponds to solenoid valve status OFF and ON (0: OFF, 1: ON), and the output number starts at zero from LSB (least significant bit). -19No.EX-OMM0008-D Mounting of Objects This SI unit covers the CompoNetTM object classes below.