Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)

The ISE/ZSE20B, ISE/ZSE20C, ISE/ZSE40A, and ISE/ZSE80 series digital pressure switches feature an IP65 enclosure. The ISE/ZSE20B series (for air pressure) catalog can be found here.

Nozzle Diameter: 10 (ø1.0mm), Vacuum Pressure: L (-48 kPa), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8)

Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8)

Nozzle Diameter: 05 (ø0.5mm), Vacuum Pressure: L (-48 kPa), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)], Operation Manual: T (w/o Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: T (w/o Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only), Piping Specification: 01 (R1/8)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)