Cylinder ports (1) N1 N3 N7 N9 N11 M5 01 02 Symbol NM External pilot port 3/8 1/8 5/32 1/4 5/16 Mix Applicable tube O.D.(Inch) M5 1/8 1/4 M5x0.8 VQZ1000 V V V V V Cylinder port VQZ2000 V V V V V VQZ3000 V V V V V Note 1) Mixing One-touch fittings and thread types is impossible.
(The SI unit type is provided for use in Japan.) 01 02 03 04 06 10 1/8 V 1/4 V V V 3/8 V V 1/2 V 3/4 V V 1 V 17 Series AC Spacers and Brackets Accessories Spacer (X) D Center of F.R.L. body C 1 X-X B X RELEASE 2 Y200 Y400 X Applicable model A 6 3 4 5 5 B 27 35.5 47 57 61 C 15 18.5 26 31 33 D 33 48 59 65 70 Model Y100 Y200 Y300 Y400 Y500 Seal AC10, AC10A, AC10B AC20 AC25, AC30 AC40 AC40-
For DC voltages other than 12 V and 24 V, incorrect wiring will case damage to the surge suppressor circuit. Applied voltage 24 V 0 V Standard With power saving circuit 0.4 W 0.1 W 0 W 62 ms 1-5-76 77 Series SYJ3000/5000/7000 Specific Product Precautions 4 Be sure to read before handling.
A B 24 A B P R 42.1 16.9 39[41.2] G: Approx. 300 H: Approx. 600 (Lead wire length) 103.2[107.6] (Light/surge voltage suppressor) 50.1[57.1] + 45 34.7 21.5 6 6 17 17 15 8.5 1/8 (P, R port) 32 24 45.5 L plug connector (L): 10-SYJ5 43-L-01 3 4 5 M plug connector (M): 10-SYJ5 43-M-01 3 4 5 DIN Terminal (D): 10-SYJ5 43-D-01 3 4 5 M8 connector (WO): 10-SYJ5 43-WO-01 3 4 5 Applicable cable O.D.
V 200 V 110 V 220 V 240 V 48 V 230 V 24 V 12 V 02 (1/4) 03 (3/8) 02 (1/4) 03 (3/8) AC Note) Note) Note) The orifice diameter shown above are for the supply pressure side/ vacuum side port.
(Element life check) Max. contact capacity: 10 VA AC, 10 W DC Rated contact voltage (max. operating current): 125 V AC (0.08 A), 30 V DC (0.33 A) Max. contact capacity: 10 W DC Rated contact voltage (max. operating current): 30 V DC (0.33 A) Pressure drop 0.1 MPa Symbol V: Degreasing wash, white vaseline Reed switch Reed switch Body/housing is degreasing washed.
Example) AW30K-03BE-2N-D-X406 0.4 MPa Setting Long Bowl Symbol Description V q V q Body size Body size 20 30 40 60 20 30 40 60 V w With backflow function Nil Without backflow function V V V V V V V V K1 With backflow function V V V V V V V V + V e Pipe thread type Nil Rc V V V V V V V V N NPT V V V V V V V V F G V V V V V V V V + 01 1/8 V V 02 1/4 V V V V V V 03 3/8 V V V V 04 1/2
1 to 5 V, 0 to 5 V 0 to 20 mA, 4 to 20 mA 12 bit resolution Input signal range 10 to 10 V, 5 to 5 V 20 to 20 mA 16 bit resolution EX600-AXA 15 V 22 mA Note 2) Max. rated input signal 50 100 k Input impedance 0.05% F .S.
US1 LED . 6-6 US1 LED US1 OFF US1 OFF , (17 V ) US1 (17 V 20.4 V) ON US1 ON 21.6 V 6.4.6. US2 LED . 6-7 US2 LED US2 OFF US2 OFF , (17 V ) US2 (17 V 21.6 V) ON US2 ON 22.8 V 49 No.EX-OMU0020CN 6.5.
F.S. = 5[V] 1[V] = 4[V] 3[%F.S.] = 4 X 0.03 = 0.12[V] Detection Analog output voltage [V] Pressure indication [kPa] Switch The output error induced by the temperature change can be as much as 0.12[V]. 1.12 1 0.88 P3 0 Vacuum Pressure Rated pressure P1 P2 103 100 97 Pressure display = 100[kPa] Temperature characteristic = 3[%F.S.]
DIN terminal Closed center: VFR2310Exhaust center: VFR2410Pressure center: VFR2510L plug connector Closed center: VFR2310-LExhaust center: VFR2410-LPressure center: VFR2510-LM plug connector Closed center: VFR2310-MExhaust center: VFR2410-MPressure center: VFR2510-M01 02 01 02 01 02 01 02 01 02 01 02 01 02 D Y 01 02 D Y 01 02 D Y Applicable cable O.D. 6 to 8 [4.5 to 7] Light/Surge voltage
1 to 5 V, 0 to 5 V 0 to 20 mA, 4 to 20 mA 12 bit resolution Input signal range 10 to 10 V, 5 to 5 V 20 to 20 mA 16 bit resolution EX600-AXA 15 V 22 mA Note 2) Max. rated input signal 50 100 k Input impedance 0.05% F .S.
-02 03 3-port valve for residual pressure release Note 7) VHS40-06 01 E200-02 03 02 E300-03 04 E600-06 10 E500-06 Piping adapter Note 7) E100-M5 02 IS1000E-3003 04 01 IS1000E-2002 03 Pressure switch with piping adapter Note 7) Y54-03 04 Y24-01 02 Y34-01 02 Cross spacer Note 7) Y14-M5 Note 1) in part numbers for a round pressure gauge indicates a type of connection thread.
ADDRESS 4632 4632 4632 1 1 1 9 9 9 PW LRUN ON POWER ALARM COMM Name of terminal block, LED Note Cable wiring 2 2 2 1 ON 8 8 8 O N 3 3 3 7 7 7 4632 4 4 4 6 6 6 SD RD LERR. 5 5 5 POWER SEND x 10 x 1 1 2 3 4 5 6 7 8 OFF DG 24 V 0 V D G D G 0 V 24 V 24 V 0 V A B SG FG 0 V 24 V 24 V 0 V +24V 24G DA DB FG Description LED ON for SI unit power supply input Description LED Description LED POWER COMM
-04-12 AS1301FG-M5-23 AS2301FG-01-23 AS1301FG-M5-04 AS2301FG-01-04 -02-04 AS1301FG-M5-06 AS2301FG-01-06 -02-06 AS3301FG-02-06 -03-06 AS2301FG-01-08 -02-08 AS3301FG-02-08 -03-08 AS1211FG-M5-23 AS2211FG-01-23 AS1211FG-M5-04 AS2211FG-01-04 -02-04 AS1211FG-M5-06 AS2211FG-01-06 -02-06 AS3211FG-02-06 -03-06 AS2211FG-01-08 -02-08 AS3211FG-02-08 -03-08 AS2211FG-01-10 -02-10 AS3211FG-02-10 -03-10
(M): SY3140(R)-M-01-Q VQ5 VQZ VQD VFS VS VS7 VQ7 1.2-33 Base Mounted Type Series SY3000 Dimensions Note)< >: Values with surge voltage suppressor 2 position double Grommet (G), (H): SY3240(R)-01-Q Scale: 35% G H With interface regulator 141 15 68.5 65.6 68 32.5 24.5 With plug (12.5) (37) 41 L type plug connector (L): SY3240(R)-L-01-Q M type plug connector (M): SY3240(R)-M-01-Q 1.2-34 Base
SY100-82-3-05 SY100-82-3-06 SY100-82-2-01 SY100-82-2-02 SY100-82-2-03 SY100-82-2-04 Rated voltage 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC (115 VAC) 220 VAC (230 VAC) Voltage symbol 24 V 12 V 100 V 200 V 110 V 220 V Circuit diagram with light AC circuit DC circuit 1 2 1 2 NL: Neon light R: Resistor LED: Light emitting diode R: Resistor NL R R LED Fitting and Silencer Part No. for P, R Ports
D-A90(V)/D-A93(V)/D-A96(V) Direct Mounting Style .
01) and oilfree air supplied to the pilot port. 8. M a n i f o l d m o u n t e d v e r s i o n s o f t h e V YH y r e g a r e a v a i l a b l e .