SMC Corporation of America
Elite Part Number Search
Search Results "VXR2260-10N-5C"

Size, Body, Valve Type: 10N (Size: 1; Body Mat'l: Resin; Port Size ø8 One-touch Fitting; Orifice Dia: 5, N.C.), Voltage and Electrical Entry: G (24VDC; DIN Terminal w/Surge Voltage Suppressor)

Size, Body, Valve Type: 10N (Size: 1; Body Mat'l: Resin; Port Size ø8 One-touch Fitting; Orifice Dia: 5, N.C.), Voltage and Electrical Entry: F (24VDC; Grommet w/Surge Voltage Suppressor)

Size, Body, Valve Type: 10N (Size: 1; Body Mat'l: Resin; Port Size ø8 One-touch Fitting; Orifice Dia: 5, N.C.), Voltage and Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 1S (12VDC; Conduit w/Surge Voltage Suppressor)

Size, Body, Valve Type: 10N (Size: 1; Body Mat'l: Resin; Port Size ø8 One-touch Fitting; Orifice Dia: 5, N.C.), Voltage and Electrical Entry: A (24VDC; Grommet), Other Voltages and Electrical Options: None, Other Options: H (Low Concentration Ozone Resistant, FKM Seal, Oil-free, Rc Thread)

Size, Body, Valve Type: 10N (Size: 1; Body Mat'l: Resin; Port Size ø8 One-touch Fitting; Orifice Dia: 5, N.C.), Voltage and Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 1B (220VAC; Grommet w/Surge Voltage Suppressor)

Stroke (mm) Pulling force Bore size (mm) 40, 50, 63 80, 100 Thread size 3 10N M3 x 0.5 x 30l or more 3 24.5N M5 x 0.8 x 40lor more Remove the bolt for normal operation. It can cause lock malfunction or faulty release. Rubber cap wManual release lock type Push the M/O knob and turn it 90 counterclockwise.

Pump automatic running and stopping is repeated to prevent freezing by maintaining circulating fluid temperature at 3C to 5C. Pump automatically starts operating if the circulating fluid temperature drops below 3C. Circulating fluid is heated by the pump power generated by pump operation.

. 3) Exhaust from other equipment Use the air consumption specified for each piece of equipment as a standard. 839 Clean Exhaust Filter SFE Series RoHS How to Order SFE 11 Size/Port size Male thread type Plug-in type Symbol Port size Max. flow capacity L/min (ANR) 11 M5 x 0.8 3 42 R1/8 65 52 R1/8 130 53 R1/4 130 73 R1/4 200 Symbol Port size Max. flow capacity L/min (ANR) 3A 4 30 4B 6 65 5C

If the fluid temperature is less than 5C, the moisture in the circuit could freeze, causing damage to the seals and leading to equipment malfunction. Therefore, take appropriate measures to prevent freezing. Maintenance Operating environment Warning Warning 1. Follow the procedures given in the operation manual to perform a maintenance inspection.

Take measures to prevent freezing fluid when below 5C, since this may cause damage to the switch and lead to a malfunction. Never use the switch in an environment where there are drastic temperature changes even when these temperatures fall within the specified temperature range. Wiring Warning 1. Verify the color and terminal number when wiring.

Since moisture in the fluid can freeze when used at 5C or below, causing damage and malfunction of switches, consider measures to prevent freezing. The installation of an air dryer is recommended to remove drainage and moisture from circuits.

Take measures to prevent freezing fluid when below 5C, since this may cause damage to the switch and lead to a malfunction. Never use the switch in an environment where there are drastic temperature changes even when these temperatures fall within the specified temperature range.

Take measures to prevent moisture from freezing in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.

Temperature conditions Water (Standard) Air (Standard) Oil (Standard) Vacuum (3) (V, M) Maximum Minimum 40 1 60 5(1) 40 5 40 40 5 5(2) Pilot port Note 1) Dew point: 5C or less Note 2) 500 cSt or less Note 3) V, M in parentheses are option symbols.

When the ambient temperature is 20C 5C and rated voltage is applied. Changing coils from AC to DC and vice versa is impossible, because of different core shapes. VXD21 0, 22 0, 23 0 are possible to exchange coil from AC to DC, but impossible from DC to AC. (Hum sound may generate because of no shading coil for DC.)

When the ambient temperature is 20C 5C and rated voltage is applied. Changing coils from AC to DC and vice versa is impossible, because of different core shapes. VXP21 0, 22 0, 23 0 are possible to exchange coil from AC to DC, but impossible from DC to AC. (Hum sound may generate because of no shading coil for DC.

When the ambient temperature is 20C 5C and rated voltage is applied. Changing coils from AC to DC and vice versa is impossible, because of different core shapes.

Moisture in circuits can freeze at 5C or below, causing damage to Orings, and malfunction. Consider measures to prevent freezing. The installation of an air dryer is recommended to remove drainage and moisture from circuits. Furthermore, even though the ambient temperature range remains within specifications, do not operate in locations where there are abrupt temperature changes. 2.

Min. 60 5 (1) 40 5 40 40 5 5 (2) Note 1) Dew point: 5C or less Note 2) 500cSt or less Note 3) "V" in the parenthesis is option symbol. Options Material Tightness of Valve(Leakage) No. Description Standard Brass (Base is aluminum.)

Take measures to prevent the fluid from freezing when it is below 5C, since this may damage the switch and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensation and moisture. Never use the switch in an environment where there are drastic temperature changes even when these temperatures are within the specification. [For water] 7.