SMC Corporation of America
Elite Part Number Search
Search Results "VV5FS3-01FU-061-03-AP5"

Base Mounted Wiring: 01T (Base Mounted Plug-in w/Terminal Blocks), Stations: 4 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 03 (3/8), Thread: T (NPTF), Control Unit: AP (Air Filter w/Auto Drain, Regulator, Air Release Valve,Pressure Switch), Release Valve Rated Voltage: 5 (24VDC)

Base Mounted Wiring: 01T (Base Mounted Plug-in w/Terminal Blocks), Stations: 9 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 03 (3/8), Thread: T (NPTF), Control Unit: AP (Air Filter w/Auto Drain, Regulator, Air Release Valve,Pressure Switch), Release Valve Rated Voltage: 5 (24VDC)

Base Mounted Wiring: Base Mounted Non Plug-in Individual Lead Wire Entry, Stations: 3 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 1/4, Thread: Rc, Control Unit: Air Filter w/Auto Drain, Regulator, Air Release Valve,Pressure Switch, Release Valve Rated Voltage: 24VDC

Base Mounted Wiring: Base Mounted Plug-in w/Terminal Blocks, Stations: 4 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 1/4, Thread: Rc, Control Unit: Air Filter w/Auto Drain, Regulator, Air Release Valve,Pressure Switch, Release Valve Rated Voltage: 24VDC

Base Mounted Wiring: Base Mounted Plug-in w/Terminal Blocks, Stations: 4 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 3/8, Thread: NPTF, Control Unit: Air Filter w/Auto Drain, Regulator, Air Release Valve,Pressure Switch, Release Valve Rated Voltage: 24VDC

Base Mounted Wiring: Base Mounted Plug-in w/Terminal Blocks, Stations: 9 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 3/8, Thread: NPTF, Control Unit: Air Filter w/Auto Drain, Regulator, Air Release Valve,Pressure Switch, Release Valve Rated Voltage: 24VDC

Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 6 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 01 (1/8), Thread: Rc, Control Unit: AP (Air Filter w/Auto Drain, Regulator, Air Release Valve,Pressure Switch), Voltage of Air Release

Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Pilot Type: Internal Pilot or None, Junction Cover: 1 (One-piece Junction Cover), Stations: 6 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 02 (1/4), Thread: T (NPTF), Control Unit: AP (Air Filter w/Auto Drain, Regulator, Air Release Valve,Pressure Switch), Voltage of Air Release Valve

Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 6 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 02 (1/4), Thread: T (NPTF), Control Unit: AP (Air Filter w/Auto Drain, Regulator, Air Release Valve,Pressure Switch), Voltage of Air Release Valve

Base Mounted Wiring: Non Plug-in Individual Lead Wire Entry, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 6 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: Rc, Control Unit: Air Filter w/Auto Drain, Regulator, Air Release Valve,Pressure Switch, Voltage of Air Release Valve: 24VDC

Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: One-piece Junction Cover, Stations: 6 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: NPTF, Control Unit: Air Filter w/Auto Drain, Regulator, Air Release Valve,Pressure Switch, Voltage of Air Release Valve: 24VDC, Q: -

(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals) Alarm _Comment _061 (01-061) (1) Make sure that the Movement MOD in the step data is not 3D B RESET "Blank (Disabled)" and that numbers [1(ABS)] or [2(INC)] are input in the numerical instruction operation. (2) Set the interval time between

(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals) Alarm _Comment _061 (01-061) (1) Make sure that the Movement MOD in the step data is not 3D B RESET "Blank (Disabled)" and that numbers [1(ABS)] or [2(INC)] are input in the numerical instruction operation. (2) Set the interval time between

(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals) (1) Make sure that the Movement MOD in the step data is not Alarm _Comment _061 (01-061) 3D B RESET "Blank (Disabled)" and that numbers [1(ABS)] or [2(INC)] are input in the numerical instruction operation. (2) Set the interval time between

B RESET >+JOG (01-052) >+B RESET 65 - 112 12 0 2 3 4 5 6 7 Alarm _Comment _058 (01-058) 3A B RESET No.base PLC <> 1 1ABS 2INC 2PLC 2 14.2[2] (P.54) Alarm _Comment _061 (01-061) 3D B RESET <>+ <>+Alarm _Comment _062 (01-062) 3E B RESET <> (01-096) C RESET <> (01-097) <> C RESET <> <>OFF JOG OFF (01-098) OFF DRV C RESET <>ON SVRE ON DRIVE ON (01-099) <> SET OFF

(PLC ) Alarm _Comment _061 (01-061) <> (1) ()1(ABS)2(INC) (2)PLC 15ms(30ms) 13.2[2](P.53) 3D B RESET (+)(-) Alarm _Comment _062 (01-062) (+)(-) 3E B RESET <> (01-096) C RESET <> -64- (01-097) <> C RESET <> <>OFF JOG OFF (01-098) OFF DRV C RESET <>ON (SVRE ON) DRIVE ON (01-099) <> SET OFF DRV C RESET <> <>12 (01-103) C RESET 1 [] A [a ] 2 [SW] [] A [a ] <> <>

Electric circuit diagram 5Electric circuit diagram HAA7-061 HAA7-062 HAA15-101 HAA15-103 HAA22-143 HAA37-143 HAA Series 8 5. Electric circuit diagram ATX-OM-F004E Air-Cooled Aftercooler 6. Installation 6.

This is a legacy product, and replaced byVV5FR4-01T-061-04T, MFLD,NVFR4*00 SERIES,SIDE PORT, VALVE, VV*FR* MANIFOLD VFR SERIES, RM, VV*FR* BASE MT 1/2, .00000 lb

Six station manifrcld ass'y: sta. 1-4) NVF'I'10-5G-017 sta. 5-6) NVF1 10-3G-017 NW3F1 -30-061-017 No. ot Stgliorg I l 5 I F Mounting Brackets tPoding 01 ,d' NPIF DltrlENSlON D E F G H J x ll ta o P n s T u w x z AA BB 3.78 (96) 3.41 1.77 (,r5)0.39 (10) o.59 (15) 0.20 (5) 0.63 (16) 1.O2 (28t 3.50 (89) 1 . 1 8 (30) 0.59 (15) 2.76 (70) o.87 (21) o_20 {5) 1 . 1 8 {30} 0.67 ltTl 0.59 (ls) o.32