48 VAC, DC: 40 mA 100 VAC, DC: 20 mA IS10M-20-A IS10M-30-A IS10M-40-A IS10M-50-A Maximum operating current Separate spacers are required for modular unit.
), 0.5 W DC (21 mA) 12 VDC 1 W DC (83 mA), 0.5 W DC (42 mA) Power consumption (Current) VQD 100 VAC Inrush 0.5 VA (5 mA), Holding 0.5 VA (5 mA) 110 VAC Inrush 0.55 VA (5 mA), Holding 0.55 VA (5 mA) 200 VAC Inrush 1.0 VA (5 mA), Holding 1.0 VA (5 mA) 220 VAC Inrush 1.1 VA (5 mA), Holding 1.1 VA (5 mA) Model Response time (ms) (1) Weight (g) Flow characteristics 1 4/2 (P A/B) (2) Standard
Model: 7 (VP700), Body: 44 (Base Mounted), Pilot: R (External Pilot), Valve Electrical Entry: Y (DIN Terminal w/Connector, w/Pitch 8mm Standard), Port: 04 (1/2, VP700), Thread: N (NPT), Bracket: None, Switch Electrical Entry: M (M12 Connector, OMRON), Check Valve, External Pilot Only: None
Model: VP700, Body: Base Mounted, Pilot: External Pilot, Valve Electrical Entry: DIN Terminal w/Connector, w/Pitch 8mm Standard, Port: 1/2, VP700, Thread: NPT, Bracket: None, Switch Electrical Entry: M12 Connector, OMRON, Check Valve, External Pilot Only: None
Note 4) At the atmospheric pressure, 1 VDC or 4 mA is output. 5 VDC or 20 mA is output at the rated pressure. Note 5) Please contact SMC regarding indication with other units of pressure. 0 25 50 75 100 Input signal (% F.S.)
a CHM A MA a Cushion adjustment screw Air release R (max.)
(Option ) Multi-connector Socket side only Plug side only DMK6-23 DMK6S-23 DMK6P-23 6 DMK-C-6 DMK6-04 DMK6S-04 DMK6P-04 DMK12-23 DMK12S-23 DMK12P-23 12 DMK-C-12 DMK12-04 DMK12S-04 DMK12P-04 Specifications Applicable tubing materials Nylon, Soft nylon, Polyurethane Applicable tubing O.D.
Auto switch models Bore size (mm) 40 50 63 80 100 D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-F5/J59 D-F5W/J59W D-F5BA/F59F/F5NT D-A5/A6/A59W D-Z7/Z80 BS5-125 BMB5-032 BA7-040 BA7-040 BA7-063 CHQ CHK BT-12 BT-03 BT-04 BT-04 BT-06 CHN BS4-125 BMB4-032 BA4-040 BA4-040 BA4-063 Note 1) D-A5/A6/A59W cannot be mounted to 40, 50.
), 1.5 W DC (63 mA) (3), 0.5 W DC (21 mA) (4) 24 VDC 1 W DC (83 mA), 1.5 W DC (125 mA) (3), 0.5 W DC (42 mA) (4) 12 VDC 100 VAC Inrush 0.75 VA (7.5 mA), Holding 0.75 VA (7.5 mA) Power consumption (Current) Rubber seal 110 VAC Inrush 0.83 VA (7.5 mA), Holding 0.83 VA (7.5 mA) 200 VAC Inrush 1.0 VA (5 mA), Holding 1.0 VA (5 mA) 3 position closed center 220 VAC Inrush 1.1 VA (5 mA), Holding
-06 02 03 04 06 E400E500-06 Piping adapter Note 5) E20001 02 03 E30002 03 04 E30002 03 04 02 03 04 06 IS1000E-40 Pressure switch with piping adapter Note 5) IS1000E-20 01 02 03 IS1000E-30 02 03 04 IS1000E-30 02 03 04 Cross interface Note 5) Y2401 02 Y3401 02 Y3401 02 Y4402 03 Y5403 04 Note 1) in part number for the round pressure gauge indicates a type of connection thread.
6 mA 20 mA (PF3W511) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W521-12/14) A B C 1 V 1.8 V 5 V 4 mA 7.2 mA 20 mA (PF3W521-U30) A B C 1 V 1.48 V 5 V 4 mA 5.92 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521-12/14 50 250 PF3W521-U30 30 250 () A B C D 0.6 V 1 V 5 V 5.4 V -40No.PF-OMN0009CN-F PF3W504/520/540/511 2X A AA B DD E F G H J K L N P PF3W504 3/
The voltage and the amperage capacity of the switch or the PLC to be connected are 24 VDC, 10 mA or higher. Internal circuit RE A B REC 3. Output circuit CX There are two outputs, the NPN open collector and the PNP open collector. The maximum rating is 30 VDC, 50 mA. Operating the controller by exceeding this voltage and amperage could damage the electric circuit.
The voltage and the amperage capacity of the switch or the PLC to be connected are 24 VDC, 10 mA or higher. +V CEP1 Internal circuit 3. Output circuit There are two outputs, the NPN open collector and the PNP open collector. The maximum rating is 30 VDC, 50 mA. Operating the controller by exceeding this voltage and amperage could damage the electric circuit.
The voltage and the amperage capacity of the switch or the PLC to be connected are 24 VDC, 10 mA or higher. Internal circuit RE A B REC 3. Output circuit CX There are two outputs, the NPN open collector and the PNP open collector. The maximum rating is 30 VDC, 50 mA. Operating the controller by exceeding this voltage and amperage could damage the electric circuit.
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
V9 FN258L-16/07 Three-phase 480V 16A 0.8 mA 440VAC/50Hz 200 V Note: RoHS-compliant models are not available.
Flow Rate and Sonic Conductance Model AS1002F-mA AS2002F-mA AS2052F-mA AS3002F-mA AS4002F-mA Tubing O.D.
Current consumption 55 mA or less Protection Polarity protection Power supply voltage for sensor 1 Power supply voltage: 1.5 V Power supply current for sensor 2 Max.110 mA (However, the total power supply current of 4 input is 440 mA or less maximum) The total power supply current when used as an IO-Link device is 200 mA or less maximum Display accuracy (Linearity) 5.0%F.S.
16 IP CODE 24VDC/60 mA/IP65 24VDC/60 mA/IP65 24VDC/60 mA/IP65 24VDC/60 mA/IP65 24VDC/60 mA/IP65 24VDC/60 mA/IP65 24VDC/60 mA/IP65 24VDC/60 mA/IP65 R TYPE 1 TYPE 1 TYPE 1 TYPE 1 TYPE 1 TYPE 1 TYPE 1 TYPE 1 TYPE1 US C R C US US C R R R R R R R US C US C US C US C US C US C SERIAL NO.
+21.00 mA 0.00 to +21.00 mA 4..20 mA +3.00 to +20.90 mA +3.10 to +21.00 mA +3.00 to +21.00 mA -50No.EX-OMO0027-A Analogue I/O unit parameters (1) Parameter setting No.