Description Material AS800 AS900 y u i JIS B 2401 P-7 JIS B 2401 P-7 AQ O-ring NBR u O-ring O-ring Spring NBR NBR Stainless steel JIS B 2401 P-12 JIS B 2401 G-50 14115 JIS B 2401 P-16 JIS B 2401 G-65 14124 JIS B 2401 P-48 JIS B 2401 P-38 O-ring NBR ASV i AK ASS Dimensions: AS420/500/600 Dimensions: AS800/900 ASR ASF 2-Port size 2-Port size Dimensions Dimensions L1 L2 L4 Min.

B 0.1 Max. panel thickness D (mm) A 3.2 3.2 3.2 B 40 51 64 C 35 41 51 D 3.5 6 8 VH200 VH300 VH400 5-8-13 8 Series VH Dimensions: Panel Mounted VH41-02 to 04 VH41-06 ( ): Long handle type ( ): Long handle type 2 (A) 4 (B) 4 (B) 2 (A) 25 (32) 107.5 19 102 3 (R) 1 (P) 3 (R) 1 (P) 88 102 89 4-6.6 4-6.6 88 81 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370

Note 3) Separate spacers are required for modular unit. 227 Regulator with Built-in Pressure Gauge ARG20(K)/30(K)/40(K) Replacement Procedure is P.431 Construction ARG20/30/40 ARG20K/30K/40K B-B A-A B-B y r IN OUT !0 t o o i u B A A P K U C S O H L to The numbers are the same as the "Construction" of the Best Pneumatics No.5 Series ARG. B *BLUE links will lead to purchase pages.

Note 3) Separate spacers are required for modular unit. 227 Regulator with Built-in Pressure Gauge ARG20(K)/30(K)/40(K) Replacement Procedure is P.431 Construction ARG20/30/40 ARG20K/30K/40K B-B A-A B-B y r IN OUT !0 t o o i u B A A P K U C S O H L to The numbers are the same as the "Construction" of the Best Pneumatics No.5 Series ARG. B *BLUE links will lead to purchase pages.

Also, take measures to prevent ingress of water and foreign matter from the breathing port of the diaphragm. 5-5-10 1 3 Port Air Operated Valve Series VGA342 How to Order SA 04 VGA342 A VA Port size Passage A Normally closed (N.C.) B Normally open (N.O.) Thread type Nil Rc F G N NPT T NPTF 04 1/2 06 3/4 10 1 SA VA JIS Symbol VM N.C. N.O.

When the ambient Continuous monitoring temperature is out of the range between the temperatures set for AS.04 and AS.06, AL.03 or AL.04 may be generated at the same time when the product is turned ON.

A B A A A B A B A B A 163 143 9 9 10 A A A A A A A 42 34.5 80 B B B B B 55.5 SI Unit Please use drip proof plug assembly (AXT100-B04A) with unused conduit port (G1/2). n 1 2 3 4 5 6 7 Stations D side 8 U side 3/4" 3(R) port 1/2" 1(P) port 4 x G1/2 Conduit port 2.6 SMC SMC SMC SMC SMC SMC SMC 101.2 95.5 90.7 55.5 42.7 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 77.3 13 15.7 43.5 20.6 12 4 A 4 A 4 A 4

4 A 62.1 41.7 25.7 39.4 (58) 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 20.9 P 1 P=17.5 94.9 76.2 7.5 One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 4 : 6 : 8 L n Dimensions Formula: L1 = 17.5n + 52, L2 = 17.5n + 106 n: Stations (Maximum 16 stations) 16 332 386 412.5 423 15 314.5 368.5 400 410.5 14 297 351 375 385.5 13 279.5 333.5 362.5 373 12 262 316 337.5 348 11 244.5 298.5 325 335.5

L ZY O L ZF G H F ZP K J SP ZCUK B C E D I A 2 x 4.5 AMJ AMV AEP HEP Related Equipment A B C D E F G H I J K L Model ZFC050-02 ZFC050-23 ZFC050-04 ZFC051-01 ZFC051-03 58.5 12.75 12.75 2 3.2 4 33 25 10 10.5 10.5 12 8.5 13.75 58 12.5 12.5 1/8" 5/32" ZFC100-04 4 ZFC100-06 6 53.2 9.1 14.1 30 10 18 11.6 19.5 23 20 29 ZFC101-03 5/32" ZFC101-07 1/4" ZFC200-06 6 ZFC200-08 8 67 15.5 17.5 34 14 22

Inset the signal cable through the hole and fit the nipple A, nipple B and lock nut. Then fit the cap A, cap B and rubber bushing. Recommended cable diameter: 6 to 13 mm Signal cable entry For option B Signal cable entry Lock nut Nipple A Rubber bush Nipple B Cap B Cap A Fig. 3-9 Mounting to the cable gland Fit the nipple A and nipple B closely until it clicks.

Inset the signal cable through the hole and fit the nipple A, nipple B and lock nut. Then fit the cap A, cap B and rubber bushing. Recommended cable diameter: 6 to 13 mm Signal cable entry For option B Signal cable entry Lock nut Nipple A Rubber bush Nipple B Cap B Cap A Fig. 3-9 Mounting to the cable gland Fit the nipple A and nipple B closely until it clicks.

A B 2-P C L L C A B A B LVA10 2-F B B K LVA60 LVA20 With flow rate adjustment With indicator (Max.

, 06, 07 01, 23, 03, 04, 06, 07 AS-F 06, 07, 08, 09, 10 500 08, 09, 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) 03, 04 TMH 400 200 06, 07 02 01, 23 ASD 300 50 03, 04 100 200 AS 01, 23 100 AS-FE 0 0 0 KE 5 0 10 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Number of needle rotations AS-FG AS-FG Note) -U10/32 has the same specification as M5

D1 Port B min. port size Weight (g) D2 L1 L2 L3 L4 P Q1 Q2 M1 M2 4 4 6 KM16-06-06-3 12.8 4 6 KM16-04-04-3 16 17 17 KM16-04-06-3 6 16 16 17 19 18 3 4.5 18 4.5 12.8 68 20.9 16 11 14.5 50 10.5 65

(Refer to CAT.E501-B "Air Fittings and Tubing" pages 143 and 144 for details.)

Description Material Auto switch model 40 50 63 80 100 NBR NBR NBR NBR NBR NBR NBR NBR Piston seal Rod seal A Rod seal B Brake piston seal Cushion seal Tube gasket Cushion valve seal Piston gasket #6 #7 #8 #9 $0 $1 $2 $3 D-A5/A6/A59W D-F5/J5/F5W/J59W D-F5NTL, F5BAL, F59F D-A3/A44/G39/K39 D-B5/B6/B59W D-G5/K59/G5W/K59W D-G5BAL/G59F/G5NTL D-A3C/A44C/G39C/K39C BT-04 BT-04 BT-06 BT-08 BT-08 BD1