Type: Block and Plate for Connection, Type: Air Supply / Exhaust End Block Assembly (Tie-Rod Base) SV4000, Number of Inputs/Outputs: -, Connector: -, Mounting Method: Direct mounting, Port pipe connection port diameter: ø12 single-action pipe fitting, Rated Voltage: -, Specification: External Pilot Specifications, Thread standard: -, Dimension: -, Applicable valve: -, Pressure reduction
Type: Block and Plate for Connection, Type: Air Supply / Exhaust End Block Assembly (Tie-Rod Base) SV4000, Number of Inputs/Outputs: -, Connector: -, Mounting Method: Direct mounting, Port pipe connection port diameter: ø12 single-action pipe fitting, Rated Voltage: -, Specification: External Pilot Specifications, Silencer Built-in, Thread standard: -, Dimension: -, Applicable valve
Type: Block and Plate for Connection, Type: Air Supply / Exhaust End Block Assembly (Tie-Rod Base) SV4000, Number of Inputs/Outputs: -, Connector: -, Mounting Method: Direct mounting, Port pipe connection port diameter: ø12 single-action pipe fitting, Rated Voltage: -, Specification: Internal Pilot Specifications, Silencer Built-in, Thread standard: -, Dimension: -, Applicable valve
Response time (ms) (0.5 MPa) Type of actuation 52-SY5000 26 or less 22 or less 38 or less 52-SY7000 38 or less 30 or less 56 or less 52-SY9000 50 or less 50 or less 70 or less 2-position single 2-position double 3-position Note 1) According to dynamic performance test JIS B8375-1981. Note 2) Response time when barriers were combined with a valve.
With auto switch Basic/CS1BQ (mm) Bore (mm) 125 140 160 Stroke range (mm) S A H AL ZZ lB lC D E F G J K KA M MM N P 1/ 2 to 1000 98 50 110 47 235 145 115 36 90 43 16 M14 X 1.5 15 31 27 M30 X 1.5 35 1/ 2 to 1000 98 50 110 47 235 161 128 36 90 43 16 M14 X 1.5 15 31 27 M30 X 1.5 35 3/ 4 256.5 to 1200 106 56 120 53 182 144 40 90 43 18.5 M16 X 1.5 17 36 30.5 M36 X 1.5 39 CS1BQ125SCS1125, #1 CS1BQ140SCS1140
The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation, SV4000 NO SIZE RATING, VALVE, SV4000 SOLENOID VALVE, 2E, SV4000 NO SIZE RATING, 1.46975 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation SV4000 SOLENOID VALVE. SV4000 NO SIZE RATING. VALVE. SV4000 NO SIZE RATING. 1.76369 lb. 2I.
The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation SV4000 SOLENOID VALVE. SV4000 NO SIZE RATING. VALVE. SV4000 NO SIZE RATING. 1.32277 lb. 2E.
The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation SV4000 SOLENOID VALVE. SV4000 NO SIZE RATING. VALVE. SV4000 NO SIZE RATING. 1.32277 lb. 2E.
The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation SV4000 SOLENOID VALVE. SV4000 NO SIZE RATING. VALVE. SV4000 NO SIZE RATING. 1.22797 lb. 2I.
/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz External pilot Nil VT N.C.
-64-1A 1NA SX5000-64-1A 1NA t-1 SX3000-64-26 2A 2NA SX5000-64-26 2A 2NA t-2 Note) 24 VDC -2A: +COM. -2NA: COM. 2A 2NA SX3000-64-20 2A 2NA SX5000-64-20 t-3 2A 2NA SX3000-64-10 2A 2NA SX5000-64-10 t-4 t-5 SX5000-64-3A SX3000-64-3A In common between +COM and COM.
(V) 24, 6, 12, 48 15 to +10% of rated voltage 1.8 (With indicator light 2.1) [24 VDC: 75 (With indicator light 87.5)] Allowable voltage fluctuation (%) Note) Power consumption (W) [Current mA] DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Note) Inrush Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz
, 400, 415 VAC (50 Hz) 380 to 420 VAC (60 Hz) 420, 440, 480 VAC (50 Hz) 420 to 520 VAC (60 Hz) 220 VAC (50 Hz) 220 to 240 VAC (60 Hz) 380, 400, 415 VAC (50 Hz) 380 to 400, 400 to 415, 415 to 440 VAC (60 Hz) 440, 460 VAC (50 Hz) 440 to 460, 460 to 500 VAC (60 Hz) Outlet voltage Symbol 500 1 500 VA 100 VAC (50 Hz) 100, 110 VAC (60 Hz) 1000 2 1 kVA Singlephase 2000 2 kVA 3 4 9 200 VAC (50 Hz
.1 1-1 EDB 2A.2 1-2 EDB 2A.3 1-3 EDB 2A.4 1-4 EDB 2A 1 2A.5 1-5 EDB 2A.6 1-6 EDB 2A.7 1-7 EDB 2A.8 1-8 EDB 2B 2B.1 1 EDB 2B.2 2 EDB 30.1 DB (1) (1) (1) 30.2 DB 30 (1) (1) (1) (1) 30.3 DB (1) (1) (1) 31 31.1 / SD 8 3 8.
connector LO 110 VAC 50/60Hz 5000mm 50 3 With lead wire M [115 VAC 50/60Hz] M plug connector Without lead wire MN 220 VAC 50/60Hz 4 Without connector MO [230 VAC 50/60Hz] Without connector cable WO M8 connector For type "W", DC voltage is only available.
Please contact us for the latest version.sales@ocaire.com, MANIFOLD BLOCK ASSY, VALVE, SS5V4 MANIFOLD SV4000, 21, SS5V4 NO SIZE RATING, 0.4356 lb
40 85 20 20KJlD 25 17 45 70 Single knuckle joint Accessory Data GKM20 10 50 100 Double knuckle joint JA-Floating joint 20 10 50 70 Rubber cushion Air cushion ( ): In the case of air cushion Calculation: (Example) C85N10-50, C85F10 Basic weight 49 (10)g Additional weight 3.2/10 mm of stroke Cylinder stroke 50 mm Mounting bracket 12g 49 + 3.2 x 50/10 = 65g 65 +12 = 77g Non-rotating rod: Double
N.O. 13.5 SYA 12 NC 26.2 65.2 58.2 3R 58.2 27 50 50.1 65.2 SYJA 1P 26.2 NO 12 VZA 1/4 1(P), 3(R) port 1/8 (Pitch) P = 27.5 12(PA) port 28 M5 x 0.8 (Breathing hole) VFA 7.5 L2 L1 VFRA (Station n) (Station 1) 1/8 12(PA) port VPA4 12 SYJA 73.5 54 VZA 37.5 11 2A 2A VTA 1/4 2(A) port (Pitch) P = 27.5 28 VGA 2 stations 83.5 68.5 111 96 138.5 123.5 166 151 193.5 178.5 221 206 248.5 233.5 276 261
SY100-30-3AS Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length U Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.