} 1.6 (20) 15 EB P EA 2 x 2.2 (Positioning for manifold gasket) 27.2 (45) L plug connector with cover (LL) 3 52-SY5420-LL-01 (-F2) 5 L 156 (Lead wire length) Insulation: Red (+) Insulation: Black () 5.9 4.1 14.7 12 0.3 mm2 84.3 Cable type (TT) 3 52-SY5420-TT-01 (-F2) 5 Max.10 L (Lead wire length) 189.6 Lead wire marking No.1 (+), No.2 () 0.75 mm2 101.1 7 ATEX Compliant Body Ported Type Series
4 4 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [oC] Circulating fluid temperature [oC] 50Hz 60Hz Fig. 8-6 Cooling capacity(HRS150-A-20/40/46/46-) 8.4 Cooling capacity HRS Series 8-12 HRX-OM-S004 Chapter 8 Documents : Facility water temperature 32 oC 8.4.3 HRS100-W-20/40/46: Facility water temperature 40 oC 14 14 12 12 10 10 Cooling capacity [kW] Cooling
Threshold for alarm generation generation and other settings Code Alarm name A.RUN P.RUN A.STP Display Default Settable OFF Display range AL39 Internal unit fan stoppage Set time AL40 Dust-proof filter maintenance 500 h 1 to 9 h 12 AL41 Power stoppage AL42 Compressor standby AL43 12 Fan breaker trip AL44 12 Fan inverter error AL45 Compressor breaker trip 13 AL46 Compressor inverter error
-23ST 13.5 12 1/4" 3.2 8.4 12.7 AS221F-N01-01ST AS221F-01-04ST 1/8" 8.4 4 20.4 27.5 9.3 5/32" 9.3 20.4 27.5 12.7 14.3 AS221F-N01-03ST AS221F-01-06ST 13.5 12 R 1/8 14.2 7 35.6 1.5 31.6 6 11.6 3/16" 11.4 23.1 30.2 14.3 16.5 AS221F-N01-05ST AS221F-01-08ST NPT 1/8 12.7 14.2 7 35.6 1.5 31.6 25.3 32.4 18.5 8 15.2 AS221F-N01-07ST AS221F-01-10ST 1/4" 13.2 23.9 31 18.5 33.1 40.2 15 21 10 18.5 AS221F-N01
-23SD AS121F-U10/32-07D 13.5 1/4" 12 3.2 8.4 12.7 AS221F-01-04SD AS221F-N01-01SD 1/8" 8.4 4 9.3 27.5 20.4 5/32" 9.3 20.4 27.5 12.7 14.3 AS221F-01-06SD AS221F-N01-03SD 6 11.6 13.5 35.6 R 1/8 14.2 7.2 1.2 31.6 12 3/16" 11.4 23.1 30.2 14.3 16.5 AS221F-01-08SD AS221F-N01-05SD NPT 1/8 12.7 14.2 7.2 35.6 1.2 31.6 8 15.2 18.5 32.4 25.3 AS221F-01-10SD AS221F-N01-07SD 1/4" 13.2 23.9 31 18.5 10 18.5
'AC Only t[ounllng Style Valve unlt only Manifold mounled Foot mounting, plpe tap in body Portlng 00 = Maniiold Mounting (N\6 3114, see pg 7) 01 = 1/8" NPIF (Cv 0.8) 02 = 1/4" NPTF (Cv 1.1) Solanold Type = 24 VAG 60Hz = 115/120 V60Hz or 100/110V 50Hz = 230/240 V60Hz ot 2OOl220 vso Hz = 12 VAC 50 Hz = 12 VDC = 24YDC' available for "D" and "O" teatu.es. 07 1 0 49 52 HOWTOORDER Thls modelnumbr
A A1 MM U1 L1 RR1 A1 L1 E1 MM RR1 U1 0.4 0.2 + 0.2 + 0 0.2 0.4 0.2 0.4 10 12 16 20 +0.002 0 5 6.4 8 10 0.2 0.4 0.1 0.3 0.2 0.4 0.2 0.4 +0.002 0 5 6.5 8 10 #8-32UNC 10 12 16 20 12 16 20 25 10 12 16 20 14.6 16.6 21 25.6 RCS-01 RCS-015 RCS-02 RCS-025 RCD-01 RCD-015 RCD-02 RCD-025 21.5 32 34 41 6 6 6 8 16 25 25 30 #8-32UNC #8-32UNC #10-32UNF 1/4-28UNF 6.3 12 10.3 18 7 14 11.5 14
1 station Rc Q CE-compliant Nil CE-compliant F N T G 20 20 stations NPT NPTF A port: M5 x 0.8 B port: M5 x 0.8 Note) Applicable only for DIN terminal type How to Order Type 41: Base mounted (A, B port side ported) Applicable solenoid valve VK3140-(-Q) VK334-(-Q) Type VK3140 VV5K3 M5 05 41 Type VK334 Solenoid direction Valve stations Applicable blanking plate assembly VK3000-7-1A 01 1 station
COIL NO. 6 7.8 8.5 12 14 5.4 7 7.7 11 13 3 3.8 4.4 6 7 5C-103-A24 5C-104-A24 5C-105-A24 5C-106-A24 5C-107-A24 5C-3-K24 5C-4-K24 5C-5-K24 5C-6-K24 5C-7-K24 18.5 24 32 39 45 17 22 29 35 41 9 12 16 20 23 5C-108-A24 5C-109-A24 5C-110A24 5C-111-A24 5C-112-A24 5C-8-K24 5C-9-K24 5C-10-K24 5C-11-K24 5C-12-K24 48 54 94 120 153 43 48 85 110 138 24 28 47 60 76 5C-113-A24 5C-114-A24 5C-115-A24 5C-116
VK300-82-2-01 VK300-82-2-03 110 VAC 110V 200 VAC 200V VK300-82-2-02 VK300-82-2-04 220 VAC 220V VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD 3-2-11
Terminal no.12 Switch Terminal no. 12 11 Recommended accessory cable dia. is 0.14 to 1.5mm2 9 10 Terminal no.1 Fig. 3-7 Wiring of contact for remote signal inputsExample 3.3 Installation HRS Series 3-12 HRX-OM-M090 Chapter 3 Transport and Setting Up 3. Plug the prepared connector in to the contact input/output connector that is on the back of the thermo-chiller.
Model AS1ll1FS-M5l AS2ll1FS-01 AS2ll1FS-02 AS3ll1FS AS4ll1FS Metric size 2 3.2 4 6 3.2 4 6 8 10 3.2 4 6 8 10 6 8 10 12 10 12 16 Tubing O.D.
Model AS1ll1FSGl-M5 AS2ll1FSGl-01 AS2ll1FSGl-02 AS3ll1FSGl AS4ll1FSGl Metric size 2 3.2 4 6 3.2 4 6 8 10 3.2 4 6 8 10 6 8 10 12 10 12 16 Tubing O.D.
Terminal no.12 Switch Terminal no. 12 11 Recommended accessory cable dia. is 0.14 to 1.5mm2 9 10 Terminal no.1 Fig. 3-8 Wiring of contact for remote signal inputsExample 3.3 Installation HRS Series 3-12 HRX-OM-R005 Chapter 3 Transport and Setting Up 3. Plug the prepared connector in to the contact input/output connector that is on the back of the thermo-chiller.
Terminal no.12 Switch Terminal no. 12 11 Recommended accessory cable dia. is 0.14 to 1.5mm2 9 10 Terminal no.1 Fig. 3-7 Wiring of contact for remote signal inputsExample 3.3 Installation HRS Series 3-12 HRX-OM-R016 Chapter 3 Transport and Setting Up 3. Plug the prepared connector in to the contact input/output connector that is on the back of the thermo-chiller.
Centigrade(oC) Fahrenheit(oF) 5.13 12 Changing pressure unit Pressure unit can be changed.
Centigrade(oC) Fahrenheit(oF) 5.13 12 Changing pressure unit Pressure unit can be changed.
Setting of the selected alarm Setting range: AL.01 to AL.51 to 63. Press the [MENU] key once. Returns to the main display (which shows the circulating fluid temperature).
C 1. ##0016 ## 00 01 1 02 2 03 3 04 4 05 5 06 6 07 7 08 8 09 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 2. **No. 3.
X A 2 10 24 1 P 3 R Manual override 34 41 3.5 (Lead wire length) 38.5 300 Cover diameter 1.4 Cross sectional area 0.2mm2 SMC 35.5 A port PE 16 12 7.5 7.5 14.5 7 7.5 1/8 NPTF P,A,R port M5 x 0.8 PE port L type plug connector (L): VQZ115(R)L -01T M type plug connector (M): VQZ115(R)M -01T 51.5 300 (Lead wire length) 60.5 300 (Lead wire length) Cover diameter 1.5 Cross sectional area 0.23mm2