Cylinder component Apply grease to the individual component, shown in the table 10. The following amount is needed per one 100 stroke cylinder. STROKE or 100mm and more Table 10. Grease apply amount 2 125 140 160 Portion to apply 100st 1517 2022 2426 50st Up 3 3 3 For grease, use lithium soap group grease JIS #2 3. Mounting seal 21 - .
400, 450, 500 CA2 Up to 1800 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper -XC5 Heat resistant cylinder (10 to 110C) -XC6 Made of stainless steel*3 *4 Up to 2700 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 -XC7 Tie-rod
Standard Strokes Bore size [mm] Standard stroke [mm] Max. manufacturable stroke 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 45 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 56 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 63 25, 50, 75, 100, 125, 150
Note 1) 5 10 5 10 D-A9 D-A9V D-M9V 5 Note 1) 5 D-M9 10 Note 1) 10 5 Note 2) D-M9W 10 Note 2) 10 5 Note 2) D-M9WV D-M9AV 10 5 Note 2) D-M9A 10 Note 2) 15 15 D-P3DW Note 1) Confirm that it is possible to secure the minimum bending radius of 10 mm of the auto switch lead wire before use.
D-M9W 10 2 pcs. D-M9WV D-M9AV 5 Note 2) 1 pc. 10 2 pcs. 5 Note 2) 1 pc. D-M9A 10 Note 2) 2 pcs. 5 1 pc. D-M9V 5 2 pcs. 5 1 pc. D-A9V 10 2 pcs. 5 1 pc. D-A9 10 2 pcs. 1 pc. 15 D-P3DWA 2 pcs. 15 Note 1) Confirm that it is possible to secure the minimum bending radius of 10 mm of the auto switch lead wire before use.
10, 25, 40, 50, 80, 100, 125, 160, 200 16 20 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 1000 25 Refer to pages 101 to 111 for cylinders with auto switches.
D-A9V D-M9V 5 2 pcs. 10 1 pc. 15 10 5 D-M9 2 pcs. 15 10 1 pc. 15 10 D-M9W 2 pcs. 15 10 1 pc. 10 D-M9WV 2 pcs. 10 1 pc. D-Z7 D-Z80 10 5 2 pcs. 15 10 1 pc. D-Y59 D-Y7P 10 5 2 pcs. 15 10 1 pc. D-Y69 D-Y7PV 5 2 pcs. 5 1 pc.
Bore size (Stroke (mm)) 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 6 8 12 16 20 25 Functional option Standard With buffer With end lock Axial piping type With buffer and end lock With buffer, Axial piping type Nil F R (2) P FR (2) FP Adjuster option Note
Minimum Stroke for Auto Switch Mounting (mm) D-M9 10 D-M9V 5 D-M9W 15 D-M9WV 10 D-A9 10 D-A9V 5 Bore size (mm) 321, 40 502, 63 No. of auto switch mounted With 1 pc. 10 5 15 15 10 10 With 2 pcs. 1 The outline dimensions for 5 mm stroke will be the same as those for 10 mm stroke. 2 The outline dimensions for 10 mm stroke will be the same as those for 15 mm stroke. 10 Prior to Use Auto Switches
1 Auto Switch Guide Reed Switches/Solid State Switches For Rotary Actuators (Air Grippers) Applicable Auto Switch Auto switch mounting Applicable air grippers Applicable rotary actuators Auto switch model Electrical entry Page Type CRB2 Size Size CRBU2 30 50-100 10/15 20-40 10-40 32/40 1/3 7/20 10-200 05/1 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB2 CDRBU2 CDRQ2MRQ
1 Auto Switch Guide Reed Switches/Solid State Switches For Air Grippers (Rotary Actuators) Applicable Auto Switch Auto switch mounting Applicable rotary actuators Applicable air grippers MHZ Auto switch model Electrical entry Size Page Type Size MHF 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ2 MRQ MDSUB
1 Auto Switch Guide Reed Switches/Solid State Switches For Air Grippers (Rotary Actuators) Applicable Auto Switch Auto switch mounting Applicable rotary actuators Applicable air grippers MHZ Auto switch model Electrical entry Size Page Type Size MHF 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ2 MRQ MDSUB
Minimum Stroke for Auto Switch Mounting (mm) D-M9 10 D-M9V 5 D-M9W 15 D-M9WV 10 D-A9 10 D-A9V 5 Number of auto switches mounted Bore size (mm) 32 1, 40 50 2, 63 1 10 5 15 15 10 10 2 1 The outline dimensions for 5 mm stroke will be the same as those for 10 mm stroke. 2 The outline dimensions for 10 mm stroke will be the same as those for 15 mm stroke. 7 Prior to Use Auto Switches Common Specifications
50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200 300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) Allowable side load F(N) 1 N: Approx. 0. 102 kgf F Stroke (mm) Bore size (mm) Model 25 50 75 100 125 150 175 200 MGTM 140 151 162 176 193 212 178 204 63 MGTL 199 212 226 243 170 186 127 143 MGTM 199 213 228 246
It same for mounting bracket {Refer to Table 10 (P30)} Short Long Table 8. Tightening torqueA 1 3 5 Bore size Width across flats Tightening torque[Nm] 32,40 6 5.1 50,63 8 11.0 80,100 10 25.0 2 4 125 12 30.1 Tie rod tightening order. 26 3-2-2. Removal of seals 1) Rod seal Insert a precision screwdriver from the front of the cover to pull out the seal as shown in Fig. 10.
Bore size (Stroke (mm)) 6 8 12 16 20 25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 Applicable Auto Switches/Refer to Best Pneumatics No. 3 for further information on auto switches.
Bore size (mm) Standard stroke (mm) Maximum manufacturable stroke (mm) 10 15, 30, 45, 60, 75, 100, 125, 150 400 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 400 Symbol Specications -XAl Change of rod end shape -XC3 Special port location -XC9 Adjustable stroke cylinder/Adjustable retraction type Note 1) Manufacture of intermediate strokes at 1 mm intervals is possible.
Auto switch model D-M9NV D-M9N D-M9B D-M9BV D-M9PV D-M9P Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular Wiring type 2-wire 3-wire NPN PNP Output type Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 24 VDC (10 to 28 VDC) 28 VDC or less Load
Standard CE marking Lead wires Oilproof heavy-duty vinyl cable: 2.7 x 3.2 ellipse D-M9B(V) 0.15 mm2 x 2 cores D-M9N(V), D-M9P(V) 0.15 mm2 x 3 cores Note 1) Refer to page 10 for solid state switch common specifications. Note 2) Refer to page 10 for lead wire lengths.