SMC Corporation of America
Elite Part Number Search
Search Results "RZQA32-125-30-M9N4"

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50/30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:

Mounting: Both Ends Tapped, Bore Size: 32mm, Thread: Rc, Full Stroke: 75mm, First Stroke: 30mm, Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Mounting: Both Ends Tapped, Bore Size: 32mm, Thread: Rc, Full Stroke: 50mm, First Stroke: 30mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 3 pcs.

Note2) The standard strokes of CKG1 are 50, 75, 100, 125 and 150 mm.

Form w 1 Material e Buffer spec. r Buffer stroke t Vacuum inlet y Connection thread A 10 87 53 23 Width across flats 12 20 125 63 51 30 135 73 40 171 83 77 50 181 93 10 42 26 D C B 10 89.5 55.5 23 20 127.5 65.5 51 30 137.5 75.5 40 173.5 85.5 77 50 183.5 95.5 Width across flats 7 13 14 3 2.5 6 M10 x 1 44.5 28.5 10 91 57 23 20 129 67 51 30 139 77 40 175 87 77 50 185 97 16 46 30 N4 N6 U4 U6

) 100 + 100 (n 2) (n = 2, 3, 4) 95 + 30 (n 2) (n = 2, 3, 4) 105 + 30 (n 2) (n = 2, 3, 4) 105 + 100 (n 2) (n = 2, 3, 4) Different surfaces D-G39 D-K39 D-A3 Note 1) n 100 + 100 (n 2) (n = 2, 3, 4) same surface 1 95 115 105 80 10 35 55 Different surfaces same surface 2 110 100 85 120 35 + 30 (n 2) (n = 2, 3, 4) 85 + 30 (n 2) (n = 2, 3, 4) 100 + 30 (n 2) (n = 2, 3, 4) 110 + 30 (n 2

(A contact) 50 75 100 125 150 50mm 75mm 100mm 125mm 150mm Use a driver with CE marking. N.O.

Bore stroke 32 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 700 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 800 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600, 700, 800 1400 100 25, 50, 80, 100, 125, 160, 200,

12 55 82 4 100 130 7 M22 x 1.5 80 3/8 130 28 17 212 100 to 1500 40 37 41 125 60 30 29 20 71 16 M12 x 1.75 10 26 14 70 83 6 120 160 8 M26 x 1.5 100 1/2 131 30 15 216 110 Foot brackets and plug bolts are installed before shipment from factory.

to 200 59 49.5 201 to 400 76 58 25 20 29 20 to 39 22 36 50 M6 x 1 8.5 5 6 40 to 100 36 43 101 to 124 80 125 to 200 53 51.5 201 to 500 70 60 32 25 30 Note 1) Range within which the rod can move.

1/4 37 114 11 17 15 50 50 73 R0.5 M10 x 1.5 25 9 73 53 20 28 17 17 20 10 22 M16 x 1.5 30 3/8 43 116 11 19 15 63 55 80 R0.5 M10 x 1.5 28 8 80 60 22.4 30 17 17 22 10 25 M18 x 1.5 30 3/8 47 120 11 21 15 80 65 90 R2.5 M12 x 1.75 32 8 100 75 28 32 22 20 26 13 29 M22 x 1.5 35 1/2 57 132 11 26 25 100 80 100 R2.5 M12 x 1.75 38 6.5 118 90 35.5 35 27 19 27 13 34 M27 x 2 35 1/2 66 140 12 34 32 125

LS + Stroke Z (mm) 4 4 4 4 LC 7 7 6 6 LD 30 25 22 20 LH 3 3 3 3 LT 16.5 16 15 15 X 8.5 8 7 7 Y 4 3.5 3.5 3 M B 60 69 69 69 LS 54 44 36 32 LX 187 175 173 163 ZZ 10 10 10 10 W 71 58 49 44 LZ Z Bore size 63.5 53 52 47 38.5 34 40 32 25 20 54.5 45 10 12 55 74 4.5 100 125 5 20 28.5 80 101 6 11 65 74 6 120 150 7 20 30 100 121 6 14 50 63 70.5 5 5 40 45 4.5 4.5 17.5 17.5 75.5 22 22 11 13 5 5 67 67

Centralized wiring and piping directions Specifications Max. number of outputs: 32 (Valve + Ejector) Valve stations: 2 to 24 stations (Max. number of outputs: 30, Depends on whether single or double) Ejector stations: 1 to 8 stations (Max. number of outputs: 16) Wiring and piping for valves and ejectors can be arranged in the same direction.

Bore size/Stroke (mm) 6 10, 20, 30, 40, 50 8 10, 20, 30, 40, 50, 75 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Adjuster option Nil Without adjuster Functional option AS Extension end adjuster AT Retraction end adjuster Nil Standard A Both ends adjuster P Note) Axial piping CS Extension

150 160.5 4 86.5 114.5 137.5 148 3 76 104 125 135.5 2 65.5 93.5 125 135.5 L1 L2 (L3) (L4) Vacuum ejector unit style: Equation L1=10.5n+28.7+(number of ejector units X 26.7) L2=10.5n+56.3+(number of ejector units X 26.7) L4 is L2 plus about 30. 1.10-146 Note) Manifolds with SI unit for Matsushitas MEWNET FP and Allen Bradley Co.s model are the same with L5, L6 and L7 dimensions of dust-proof

Limit switch 10 20 30 Cable entry direction None B contact specification 2 pcs.

x 0.8 M5 x 0.8 Series SYJ3000 20, 30, 40, 50, 75, 100, 125, 150, 175, 200 20 30 M5 x 0.8 M5 x 0.8 M5 x 0.8 10 36 64 17 26 74 47 30 72 2 4 46 52 18 8 13 37 10 60 19 13 MVGQ Note 1) It is possible to manufacture the intermediate strokes other than the standard strokes by means of installing a spacer.

Bore size/Stroke (mm) Data 10 25, 50, 75, 100 16 25, 50, 75, 100, 125, 150, 175, 200 End lock 20 25, 50, 75, 100, 125, 150, 175, 200 25 25, 50, 75, 100, 125, 150, 175, 200 R End lock 32 (25), 50, 75, 100, 125, 150, 175, 200 Nil None Note 1) For (25) stroke, the shock absorber is mounted on a single side of the plate.