, D-A93, D-A96, D-A90V, D-A93V, D-A96V Stroke B Stroke E Model Operating range A 10 20 30 40 75 100 125 150 10 20 30 125 75 100 40 50 150 50 3.6 (1.1) 3.6 (1.1) 3.6 (1.1) 15.6 (13.1) 21.6 (19.1) MXS6 5.6 5.6 5.6 17.6 23.6 4.5 5.9 45.9 (43.4) 8.9 (6.4) 3.9 (1.4) 4.9 (2.4) 12.9 (10.4) 20.9 (18.4) MXS8 47.9 10.9 5.9 6.9 14.9 22.9 5 7.6 A E CL 39.4 (36.9) 68.4 (65.9) 26.4 (23.9) 16.4 (13.9) 6.4

, D-F9WV D-A9V D-M9, D-F9W D-M9V No. of auto switches mounted 2 pcs. 15 Note) 10 10 5 MK(2) 10 Note) 15 Note) 1 pc. 5 5 Note) Please consult with SMC for shorter stroke length than indicated in the table.

, D-F9WV D-A9V D-M9, D-F9W D-M9V No. of auto switches mounted 2 pcs. 15 Note) 10 10 5 MK(2) 10 Note) 15 Note) 1 pc. 5 5 Note) Please consult with SMC for shorter stroke length than indicated in the table.

Same surface Same surface D-A9 D-M9 D-M9W 10 note) 45 45 + 45 (n-2) D-C7 D-C80 10 50 50 + 45 (n-2) D-H7 D-H7W D-H7BAL/H7NF 60 + 45 (n-2) 10 60 D-C73C D-C80C D-H7C 65 + 50 (n-2) 10 65 D-B5/B64 D-G5/K59 D-B59W 75 + 55 (n-2) 10 75 D-B7/B80 D-G79/K79 50 + 45 (n-2) 10 45 Note) For cylinders with 2 auto switches D-A93/M9/M9W.

Auto Switch Mounting Height [mm] D-F5m D-F5mW D-J59 D-J59W D-F59F D-F5BAL D-F5NTL Auto switch model D-Y59m D-Y7P D-Y7mW D-Y7BAL D-Z7m D-Z80 D-M9mV D-M9mWV D-M9mAV D-A9mV D-M9m D-M9mW D-M9mA D-A9m D-Y69m D-Y7PV D-Y7mWV D-A5m D-A6m D-A59W D-G39 D-K39 D-A3m D-A44 D-P4DW Bore size Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 32 24.5 23 30.5 23 32.5 25 35 24.5 25.5 23 26.5 23 67 27.5

Stopper (mm) Adjustment bolt Model Stroke adjustment range L L CY1H10, CY1H15, 0 to 15 CY1H20 CY1H25, CY1HT25, 0 to 30 CY1HT32 57 58 Series CY1 Auto Switch Specifications Auto switch application table Auto switch part number Cylinder model CY1R CDY1S CY1L CY1H D-A72, D-A73, D-A80 Reed switches Solid state switches D-A72H, D-A73H, D-A76H, D-A80H D-A73C, D-A80C Note 1) D-A90, D-A93, D-A96

Auto Switch Mounting Height [mm] Auto switch model D-F5m D-J59 D-F59F D-F5mW D-J59W D-F5BA D-F5NT D-Y59m D-Y7P D-Y7mW D-Y7BA D-Z7m D-Z80 D-M9m D-M9mW D-M9mA D-A9m D-A9mV D-M9mV D-M9mWV D-M9mAV D-A5m D-A6m D-A59W D-Y69m D-Y7PV D-Y7mWV D-P3DWA D-P4DW D-G39 D-K39 D-A3m D-A44 Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 32 24.5 23 27.5 23 30.5 23 32.5 25 35 24.5 67 27.5 77

15 Auto switch model Bore size (mm) D-A9 A dimension D-M9 B dimension C dimension D dimension D-A9 D-M9 D-A9 D-M9 D-A9 D-M9 21.5 76.5 72.5 56.5 60.5 17.5 15 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 A dimension D-Y5 D-Y6 D-Y7 B dimension C dimension D dimension Auto switch model D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8

case of 15. 25, 32 A dimension D-Y5 D-Y6 D-Y7 B dimension C dimension D dimension Auto switch model D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 Bore size (mm) 25 22 103 103 47 47 78 78 22 32 30.5 117.5 117.5 55.5 55.5 92.5 92.5 30.5 Operating Range Bore size (mm) Auto switch model 32 25 15 D-A9 8 D-M9 3 D-Z7/Z8 9 9 D-Y5/Y6/Y7 6 7 Since this

Auto Switch Mounting Height (mm) Auto switch model Band mounting D-C7m/C80 D-H7m/H7mW D-H7NF D-H7BA D-M9mV D-M9mWV D-M9mAV D-A9mV D-M9m D-M9mW D-M9mA D-A9m D-C73C D-C80C D-H7C D-A7m D-A80 Hs Hs Hs Hs Hs Hs Bore size 10 17 18 17 19.5 20 16.5 16 20.5 21 20.5 23 23.5 19.5 (mm) Auto switch model Rail mounting D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV D-A9m D-A9mV D-A7mH/A80H D-F7m/J79 D-F7mW

-X 663 CE1 Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height D-A9V D-M9V D-M9WV D-M9AV D-A9 D-M9 D-M9W D-M9A 12 to 20 25 U B A 32 to 63 D-A9 D-M9 D-M9W D-M9A D-A9V D-M9V D-M9WV D-M9AV U D-A7 D-A80 D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F79F D-F7NT D-F7BA D-A73C D-A80C D-J79C D-A79W D-F7WV D-J7V D-F7BAV 12 to 20 U B A 32 to 63

CY D-A93 Less than 50 strokes CX D-M9 D-M9W Less than 55 strokes Less than 20 strokes MQ RHC RZQ D-X Individual -X 1037 Series REC Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Reed auto switch Solid state auto switch D-M9 D-M9W D-A9 Hs Hs Auto switch Auto switch 8.5 8.5 A 22 A B B 16.5 16.5 22 (24.5) ( ): For D-A93 type D-C7, C80 D-G5NTL 8.5 12

CY D-A93 Less than 50 strokes CX D-M9 D-M9W Less than 55 strokes Less than 20 strokes MQ RHC RZQ D-X Individual -X 1037 Series REC Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Reed auto switch Solid state auto switch D-M9 D-M9W D-A9 Hs Hs Auto switch Auto switch 8.5 8.5 A 22 A B B 16.5 16.5 22 (24.5) ( ): For D-A93 type D-C7, C80 D-G5NTL 8.5 12

CY D-A93 Less than 50 strokes CX D-M9 D-M9W Less than 55 strokes Less than 20 strokes MQ RHC RZQ D-X Individual -X 1037 Series REC Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Reed auto switch Solid state auto switch D-M9 D-M9W D-A9 Hs Hs Auto switch Auto switch 8.5 8.5 A 22 A B B 16.5 16.5 22 (24.5) ( ): For D-A93 type D-C7, C80 D-G5NTL 8.5 12

However, if there is any problem, use a 3 wire DC style. 3.8-11 Series CXT Auto Switch Mounting Position and Mounting Height Reed switch Solid state switch A B W D-F9NW D-F9PW D-F9BW D-A90 D-A93 D-A96 D-F9N D-F9P D-F9B D-F9BAL 12 A B W 16, 20, 25 W A B 32, 40 (mm) D-A90 D-A93 D-A96 D-F9NW D-F9PW D-F9BW D-F9N D-F9P D-F9B Auto switch model D-F9BAL Symbol A B W A B W A B W Standard stroke 12

D-A93 45 to less than 50 stroke D-M9 D-M9W 45 to less than 55 stroke 15 to less than 20 stroke Operating Range (mm) Auto switch model Bore size (mm) 20 25 32 40 D-A9 D-M9/M9W 6 6 6 6 3.5 3 3.5 3 D-C7/C80 D-C73C/C80C 7 8 8 8 D-B5/B64 D-B59W 8 8 9 9 12 12 13 13 D-H7/H7W D-G5NTL/H7NF 4 4 4.5 5 D-H7C 7 8.5 9 10 Since the operating range is provided as a guideline including hysteresis, it cannot

Applicable models: D-A73, A73H, D-A93, A93V 2) Note however, that in the case of 2 color indicator type auto switches (D-A79W), if the wiring is reversed, the the switch will be in a normally ON condition.

B D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Parallel electrical entry B A A D Reed Switch D-A90(V), D-A93(V), D-A96(V) Reed Switch D-A90(V), D-A93(V), D-A96(V) Set screw (included to auto switch) (mm) Stroke (mm) 20 45 25 51 31 Stroke (mm) 10 34.5 35.5

Individual -X 81 Series MXS Auto Switch Proper Mounting Position (Detection at Stroke End) Reed Auto Switch: D-A90, D-A93, D-A96, D-A90V, D-A93V, D-A96V Stroke B Stroke E Model A 10 40 10 20 30 125 40 50 150 100 75 75 20 50 100 30 150 125 MXS6 MXS8 MXS12 MXS16 MXS20 MXS25 3.6 (1.1) 8.9 (6.4) 26.4 (23.9) 26.7 (24.2) 30.6 (28.1) 35.5 (33) 3.6 (1.1) 3.9 (1.4) 16.4 (13.9) 16.7 (14.2) 20.6 (18.1