Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,
Magnet: Built-in, Mounting: Double Clevis, Bore Size: 40mm, Port Thread Type: Rc, Stroke: 40mm, Body Option: Rod End Male Threads, Locking Direction: Extension Locking, By-Pass Piping: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Double Clevis, Bore Size: 40mm, Port Thread Type: Rc, Stroke: 100mm, Body Option: Rod End Male Threads, Locking Direction: Retraction Locking, By-Pass Piping: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Double Clevis, Bore Size: 40mm, Port Thread Type: Rc, Stroke: 100mm, Body Option: Rod End Female Threads, Standard, Locking Direction: Extension Locking, By-Pass Piping: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,
SQ1000 SQ2000 SSQ1000 4 1A SSQ2000 4 1A Option Option Nil B R None Back pressure check valve External pilot specifications Note) Enter -BR for both options.
Note) Enter "-BR" for both specifications. Nil B R None 16 16 stations Back pressure check valve Note) No symbol required for "F0". External pilot specification Note) Enter "-BR" for both specifications. 53 Series SQ1000/2000 3. Connection method (Refer to page 52 regarding the procedures for adding stations to a manifold block.)
<br><br>Internal pilot type valves<br><br><br>With the solenoid’s electromagnetic force, a small pilot operated valve (direct operated 3-port valve) is switched, and the supply pressure is sent to the main valve, which switches the main valve.
<br>Mounting interchangeability:<br>Mounting screws, brackets, and manifolds for the underside of the valve have not been changed.<br>The main changes are as follows.<br>① The max. allowable operating pressure of old VT307 series valves is 0.9 MPa. While the max. allowable operating pressure of new VT307 series valves (standard) is 0.7 MPa.
<br>Refer to the “How to Order” section in the catalog.<br>The part numbers when replacing only the upper valves for use with the existing sub-plates (pipe section) are “VS4124-00□” and “VS4134-00□.”<br>A gasket and bolt are included. <br>Ex.)
<br>The VS3135 and VS3145 series catalogs can be found here.<br><br>The VS3135 and VS3145 series have been in production for more than 40 years.<br>There are no interchangeable current products, but the following models are listed for reference.
<br>For the VF2□00 series base mounted plug-in type: the VFS2□00 series (Note 1)<br>For the VF2□10 series base mounted non plug-in type: the VFS2□10 series (Note 1)<br>For the VF2□20 and VF2□30 series body ported type: the VFS1□20 and VFS1□30 series <br>*1) For the base mounted type, valves of the VFS2000 series can be mounted on old VF2000 series manifolds and sub-plates.
① Mounting: Body (groove) mounting only<br>② Load voltage: DC or AC<br>③ Switch contact: Reed or solid state<br>④ Wiring: 2-wire or 3-wire<br>⑤ Environment: Improved water resistance<br>⑥ Diagnostic display: 2-color display<br>⑦ Lead wire length: 0.5, 1, 3, or 5 m, etc. should be selected from the switches shown in the catalog. The CUJ/CU/CUK series catalogs can be found here.
<br><br>When using or planning to use a cylinder with a solid state auto switch and ordering only the cylinder, suffix “-X1810” to the end of the part number.<br>Ex.) MY1B10G-300-X1810<br><br>For cylinders ordered with a solid state auto switch, the suffix “-X1810” does not need to be added. Just use the part number “MY1B10G-300-M9BW.”
<br>Note that a grease pack does not come with the seal kits. <br>Order the grease for the standard MGP series product using the part number “GR-S-010.” <br>Be sure to check the part number of the MGP-Z series product before ordering the seal kit. The old MGP series was discontinued in April 2012.
<br>Old product: <br>Rubber bumper: CG1N□-PS <br>Air cushion: CG1A□-PS<br>Refreshed product: <br>Rubber bumper & air cushion: CG1N□Z-PS (the number in the “□” indicates the cylinder I.D.) <br>Note 1) There is no seal kit part number for bore sizes ø50 and larger because the products cannot be disassembled by the customer.
<br>Refreshed MB and MB1 series products have a “Z” after the stroke in the part number. Keep in mind that no changes were made to the mounting dimensions. <br>The features of the MB-Z series can be found here. <br><br>The main changes made to refreshed MB□ series cylinders are as follows.