<br>Max. operating temperature of the TL/TIL, TLM/TILM, and TD/TID series (fixed use) <br>Air/inert gases: 260°C<br>Water: 100°C <br>Max. operating temperature of the TH/TIH series (fixed use) <br>Air/inert gases: 200°C <br>Water: 100°C<br>

<br>EX126: IP67 enclosure<br>EX250: I/O compatible (sensors and external devices can be connected), IP67 enclosure<br>EX260: Compact, Space saving, Transition wiring between manifolds is possible, IP67 enclosure (The D-sub is IP40)<br>EX500: Gateway unit, IP67 enclosure<br>EX600: Fieldbus communication allows for increased expansion, I/O compatible, IP67 enclosure<br><br>For further details

Internal pilot type (standard):<br>This type supplies pilot pressure for driving the main valve from the SUP port of the valve.<br><br>External pilot type (semi-standard):<br>This type supplies pilot pressure for driving the main valve from the external pilot port (X port).

<br><br>① The basic type, flange type, and foot type are interchangeable with the new products. However, the overall length is 6 to 9.5 mm shorter.<br>Note 1) For bore sizes ø6 and ø10, the piping port size has been changed from M5 to M3.

<br><br>Special order part number suffix “-XC92”: For fine powder (30 μm or less) <br>These cylinders are ideal for use in environments where fine powders such as ceramic powder, toner powder, paper powder, and metal powder (excluding welding spatter) are airborne.

<br>Note) The MXS is smaller in terms of the amount of deflection (displacement) of the table. Select the new MXQ-Z, existing MXQ, or MXS series air slide table that best suits the application. <br><br>The MXQ-Z series catalog can be found here.

<br>MHF2-8D: 2.5 mm<br>MHF2-12D: 2.5 mm<br>MHF2-16D: 2.5 mm<br>MHF2-20D: 3.0 mm<br>Note 1) The operating range value is the value per finger. Double the value in relation to the workpiece diameter. <br>Note 2) This value is to be used as a guide, not a guaranteed value. <br>Note 3) The actual value may vary by up to 30% depending on the operating environment.

<br><br>Internal circuit and wiring example 1: NPN output type, NPN open collector 1 output, Max. applied voltage 26.4 V, Max. load current 80 mA, Residual voltage 2 V or less <br><br>Internal circuit and wiring example 2: PNP output type, PNP open collector 1 output, Max. load current 80 mA, Residual voltage 2 V or less<br><br>

<br>When the release valve is turned ON (energized), vacuum release air is generated until the valve is turned OFF (de-energized).<br>Set the energization time for each solenoid valve with a PLC or other master device.<br><br>