SMC Corporation of America
Elite Part Number Search
Search Results "RDLQA32TF-50M-F"

Set value correction by auto shift function Supply pressure normal Supply pressure drop Supply pressure increase F Reset function P-1 C-5 C-5 (P-3) (Differential) Pressure This function clears and resets the zero value on the display of measured (differential) pressure within 7%F.S. of the factory adjusted value.

SW RESET RUN2 RUN1 OV INPUT 6 7 5 8 4 + 9 3 SET UP A 2 B 1 0 C D 1 E F 0 to 10V V R 1 OUTPUT SET UP BALANCE CONTROLLER VYU5-D 2 V R 2 OV ERR.

How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)

Size, Body, Valve Type: 50M (Size: 2; Body Mat'l: Resin; Port Size ø10 One-touch Fitting; Orifice Dia: 7, N.O.), Voltage and Electrical Entry: F (24VDC; Grommet w/Surge Voltage Suppressor)

Mounting clearance (mm) Bore size (mm) 40 20 46 25 56 32 Clearance 6 Series CU Auto Switch Specifications Auto Switch Common Specifications Type Reed switch Solid state switch Leakage current None 3-wire: 100A or less; 2-wire: 0.8mA or less Operating time 1.2ms 1ms or less Impact resistance 300m/s 50M or more at 500VDC (between lead wire and case) 1000m/s Insulation resistance 1500VAC for

Developed to be combined with our extensive line of fittings, the addition of the TILM tube provides a complete solution for your piping equipment needs., FLUOROPOLYMER,TUBING NAT 50M, TUBING, FLUORO. TL/TIL, TD/TID, TH/TIH, H09, 9.64 lb

(Example) D-Y7NWL Impact resistance . 1,000m/s (102G) Insulation resistance . 50M or more at 500VDC (between lead wire and case) Withstand voltage . 1000VAC for 1 min. (between lead wire and case) Ambient temperature ... 10 to 60C (14 to 140F) Enclosure .

(Example) D-Y7NWL Impact resistance . 1,000m/s (102G) Insulation resistance . 50M or more at 500VDC (between lead wire and case) Withstand voltage . 1000VAC for 1 min. (between lead wire and case) Ambient temperature ... 10 to 60C (14 to 140F) Enclosure .

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: TF (G), Stroke: 75mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: TF (G), Stroke: 100mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: TF (G), Stroke: 75mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: TF (G), Stroke: 40mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 32mm, Port Thread Type: G, Stroke: 75mm, Body Option: Rod End Female Threads, Standard, Locking Direction: Extension Locking, By-Pass Piping: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 32mm, Port Thread Type: G, Stroke: 100mm, Body Option: Rod End Male Threads, Locking Direction: Extension Locking, By-Pass Piping: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 32mm, Port Thread Type: G, Stroke: 40mm, Body Option: Rod End Male Threads, Locking Direction: Extension Locking, By-Pass Piping: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,

D-M9P DC24V DC12V Relay PLC 2-wire D-M9BV D-M9B DC24V DC5V,12V 3-wire (NPN) D-M9NWV D-M9NW DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PWV D-M9PW Yes Grommet DC24V DC12V Relay PLC 2-wire D-M9BWV D-M9BW DC24V DC5V,12V 3-wire (NPN) D-M9NAV D-M9NA DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PAV D-M9PA DC24V DC12V Relay PLC D-M9BAV D-M9BA DC24V 2-wire Isolation resistance i 50M

D-M9P DC24V DC12V Relay PLC 2-wire D-M9BV D-M9B DC24V DC5V,12V 3-wire (NPN) D-M9NWV D-M9NW DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PWV D-M9PW Yes Grommet DC24V DC12V Relay PLC 2-wire D-M9BWV D-M9BW DC24V DC5V,12V 3-wire (NPN) D-M9NAV D-M9NA DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PAV D-M9PA DC24V DC12V Relay PLC D-M9BAV D-M9BA DC24V 2-wire Isolation resistance i 50M

when ON) DC5V,12V D-F59 DC24V 3-wire (NPN) IC circuit Relay PLC 3-wire(PNP) DC5V,12V D-F5P DC24V DC12V D-J59 DC24V Relay PLC 2-wire AC100V D-J51 AC200V DC5V,12V Yes Grommet D-F59W DC24V 3-wire (NPN) IC circuit Relay PLC 3-wire(PNP) DC5V,12V D-F5PW DC24V DC12V D-J59W DC24V Relay PLC 2-wire DC12V D-F5BA DC24V DC5V,12V IC circuit Relay PLC D-F59F DC24V 4-wire (NPN) Isolation resistance i 50M