Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 100mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 32mm, Port Thread Type: Rc, Stroke: 100mm, Body Option: Rod End Female Threads, Standard, Locking Direction: Extension Locking, By-Pass Piping: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 32mm, Port Thread Type: Rc, Stroke: 50mm, Body Option: Rod End Female Threads, Standard, Locking Direction: Extension Locking, By-Pass Piping: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 32mm, Port Thread Type: Rc, Stroke: 100mm, Body Option: Rod End Male Threads, Locking Direction: Extension Locking, By-Pass Piping: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: Rod End Male Threads, Locking Direction: Extension Locking, By-Pass Piping: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1
D-M9P DC24V DC12V Relay PLC 2-wire D-M9BV D-M9B DC24V DC5V,12V 3-wire (NPN) D-M9NWV D-M9NW DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PWV D-M9PW Yes Grommet DC24V DC12V Relay PLC 2-wire D-M9BWV D-M9BW DC24V DC5V,12V 3-wire (NPN) D-M9NAV D-M9NA DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PAV D-M9PA DC24V DC12V Relay PLC D-M9BAV D-M9BA DC24V 2-wire Isolation resistance i 50M
D-M9P DC24V DC12V Relay PLC 2-wire D-M9BV D-M9B DC24V DC5V,12V 3-wire (NPN) D-M9NWV D-M9NW DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PWV D-M9PW Yes Grommet DC24V DC12V Relay PLC 2-wire D-M9BWV D-M9BW DC24V DC5V,12V 3-wire (NPN) D-M9NAV D-M9NA DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PAV D-M9PA DC24V DC12V Relay PLC D-M9BAV D-M9BA DC24V 2-wire Isolation resistance i 50M
when ON) DC5V,12V D-F59 DC24V 3-wire (NPN) IC circuit Relay PLC 3-wire(PNP) DC5V,12V D-F5P DC24V DC12V D-J59 DC24V Relay PLC 2-wire AC100V D-J51 AC200V DC5V,12V Yes Grommet D-F59W DC24V 3-wire (NPN) IC circuit Relay PLC 3-wire(PNP) DC5V,12V D-F5PW DC24V DC12V D-J59W DC24V Relay PLC 2-wire DC12V D-F5BA DC24V DC5V,12V IC circuit Relay PLC D-F59F DC24V 4-wire (NPN) Isolation resistance i 50M
3m or less 30m or less If the number of connected slave is 16 or less, 50m at max for total stay length is available even specific flat cable.
If driving a load such as a relay that generates a surge voltage, use a switch with a built-in contact protection circuit or use a contact protection box. 1) For an auto switch without a contact protection circuit, use a contact protection box when the wire length is 50m or longer.
with 12 VDC, 600 or less with 24 VDC Power supply voltage 12 to 24 VDC (ripple 10% or less) Current consumption 20 mA or less (without load) Enclosure IP65 Operating temperature range Operating: 0 to 50C, Stored: 25 to 85C in stock (with no condensation and freezing) Environmental resistance Voltage resistance 1000 VAC for 1 min. between external terminals and case Insulation resistance 50M
300 or less with 12VDC, 600 or less with 24VDC Power supply voltage 12 to 24VDC (ripple 10% or less) Current consumption 20mA or less (without load) Enclosure IP65 Operating temperature range Operating: 0 to 50C, Stored: 25 to 85C in stock (no freeze nor condensation) Environmental resistance Voltage resistance 1000VAC for 1 min between external terminals and case Insulation resistance 50M
Install a filter strainer of about 50m on the inlet side of the piping. 4. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. 5. Always tighten threads with the proper tightening torque.
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking), By-Pass Piping: None (Emergency Stop), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking), By-Pass Piping: None (Emergency Stop), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 25mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking), By-Pass Piping: None (Emergency Stop), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 30mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking), By-Pass Piping: None (Emergency Stop), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)