Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 30mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking), By-Pass Piping: None (Emergency Stop), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking), By-Pass Piping: None (Emergency Stop), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: Rod End Female Threads, Standard, Locking Direction: Extension Locking, By-Pass Piping: None (Emergency Stop), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 32mm, Port Thread Type: Rc, Stroke: 25mm, Body Option: Rod End Female Threads, Standard, Locking Direction: Extension Locking, By-Pass Piping: None (Emergency Stop), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,
roll available for all color types Series Table : 100m roll : 20m roll Tube size Metric size (Series TU) Inch size (Series TIUB) Model TU0425 TU0604 TU0805 TU1065 TU1208 TIUB01 TIUB05 TIUB07 TIUB11 TIUB13 Tube O.D.
Series Table : 20m roll : 100m roll Model TAS3222 TAS1208 TAS0425 TAS0604 TAS0805 TAS1065 3.2 12 Tube O.D. (mm) 4 6 8 10 8 2.2 Tube l.D.
(TPH0806, TPH1075, TPH1209) -20 0 0 20 40 60 80 Operating temperature C 10 Soft Polyolefin Tubing Series TPS Clean Tubing Series 20m bundle 100m bundle Designation TPS0425 TPS0604 TPS0805 TPS1065 TPS1208 O.D. mm 4 6 8 10 12 I.D. mm 2.5 4 5 6.5 8 White (W) Black (B) Red (R) Blue (BU) Yellow (Y) Green (G) Specifications Air, Nitrogen gas, Water (pure water) Note 1) Fluid Maximum operating
Specific flat cable SCA1-4F10 (100m) 6-4 Wiring to power supply This SI unit is multi power supply type slave and has two power ports for communication and solenoid valve. (1) Power supply for communication If VCTF is used in communication line, power is supplied for SI unit by different cable.
Operating Pressure MPa 2 TH0425 TH0806/TH1075/TH1209 How to Order TH0604 Metric size TH0604 N 20 1 TH1008/TH1210 0.5 Indication of tubing model Length per roll Roll size 20m roll 100m roll Symbol 20 100 Color indication 0 -20 0 20 40 60 80 100120140160180200 Color Symbol N R BU B Note) Translucent Red (Translucent) Blue (Translucent) Black (Opaque) Note) 100m roll is available with translucent
The TRB series is available in a variety of colors. 100m roll is available for all color types. FR double layer polyurethane tubing, Flame resistant, Equivalent to UL-94 standard V-0, 20m bundle and 100m reels available, Several color options available, TUBING, CONNECTORS, TR FLAME RESIST TUBING, LX, TR 12MM, 32.64479 lb, ModelInner tubing O.D. (mm)Inner tubing I.D.
The TRB series is available in a variety of colors. 100m roll is available for all color types. Double layer nylon tubing, Flame resistant, Equivalent to UL-94 standard V-0, Suitable for air and water piping, TUBING,FIRE RESIST,WHITE, 100M, CONNECTORS, TR FLAME RESIST TUBING, JX, TR 10MM, 21.12414 lb
Coolant (aqueous type/ oil based) Main applicable fluids Alkalescent cleaning agent, industrial water Maximum operating pressure 0.5MPa Maximum operating temperature 80 Condition: Fluid Water, Initial Body pressure drop 7kPa, Nominal filtration 100m (Refer to the flow characteristics in the catalog for other conditions.)