ISA-2-1 ISA-2-2 ISA-2-3 ISA-2-4 ISA-2-5 ISA-2-6 ISA-2-7 ISAl-1 ISAl-2/ISAl-1 ISAl-3/ISAl-2 ISAl-4/ISAl-3 ISAl-5/ISAl-4 ISAl-6/ISAl-5 ISAl-6 No.

(See Figure on page 59) Switch output NPN or PNP open collector output: 1 output NPN or PNP open collector output: 2 outputs Max. load current 80 mA Max. applied voltage 28 V (NPN output) Residual voltage 1 V or less (at 80 mA load current) 4 ms or less (with anti-chatter function: 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms, 10 s, 30 s or 60 s selected) Delay time Short circuit protection Provided

NEW ZEALAND SMC Pneumatics (N.2.) Ltd.

Eack (white) lead wire: connecl lo load (to lhe inpul of squence conlroller and outlel 3 wire sltlsn (l44ren povt sqroe lor s* bh and bsd is n01 conmofll Brown^{Red) I Pm]ffie,'e-| ' Elue.IBlack)L.: . Blue (Black) l6ad wire: Connecl lo the power source O. 2 wire system -Brown (RedE-@ I l ' : L o a d L _ o I L Bl!%(9!csiL -re o Series NCDX2 Switch Circuit cD-P12 D-A73, D-A73H.

Specification NOTE The direct current power supply to be used should be UL approved as follows : Circuit (of class 2) which is of maximum 30Vrms (42.4V peak) or less, with UL 1310 class 2 power supply unit or UL 1585 class 2 transformer. The Pressure switch is a approved product only if it has a mark on the body.

to 92.7 4 to 186 8 to 371 Instantaneous CFM x 10-2 CFM x 10-2 CFM x 10-2 CFM x 10-2 Setting/Display flow range flow CO2 0.8 to 18.5 1.8 to 46.3 4 to 93 8 to 185 CFM x 10-2 CFM x 10-2 CFM x 10-2 CFM x 10-2 Min. setting/display unit 0.1 CFM x 10-2 0.1 CFM x 10-2 1 CFM x 10-2 1 CFM x 10-2 Accumulated Setting/Display flow range 0.0 to 9.0 0.0 to 9.9 0 to 9 0 to 9 ft3 x 10-1 ft3 x 10-1 ft3 x

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: S (Bracket for w/Flow Adjustment Valve)

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: V (Panel Mount Adapter for w/Flow Adjustment

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: V (Panel Mount Adapter for w/Flow Adjustment Valve)

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Panel Mount Adapter for w/Flow Adjustment Valve

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Panel Mount Adapter for w/Flow Adjustment Valve

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -

6) 7) 20 No.ZL3-OM00801-A 9. 9.1 ZL3 ZL3M ZL3H [mm] 1.9 1.5 [MPa] 0.35 0.50 *1 -91 -93 [MPa] 280 [L/min(ANR)] + *2 300 [L/min(ANR)] 150 135 [MPa] 0.20.6 [] -550() 2] *2 20 [m/s 2] *3 100 [m /s *1 *22 2/V *310500Hz XYZ 2 *4XYZ 3 ZL6 ZL6M ZL6H [mm] 1.9x2 1.5x2 0.35 0.50 [MPa] 0.37 0.52 *1 -91 -93 [MPa] 580 [L/min(ANR)] + *2 600 [L/min(ANR)] 300 270 [MPa] 0.20.6 [] -550() 2] *

If a sealant tape is used, leave 1.5 to 2 threads exposed. 2 Wrap this way. Leave 2 threads. Sealant tape Handling Caution (1) Do not apply force when transferring, mounting and dropping the regulator with a pressure gauge.

-P10-N01 Blanking plate kit 136114A 136214A (plate, screws, and o-ring) Manifold base, 13612-*-N 13622-*-N Common IN (A1, A2) Manifold base, 13613-*-N 13623-*-N Individual IN (B1, B2) * Denotes number of stations: 2~10 available. 10 10 station NARM2000-4B2 Note1) In case of A1 and B1, a pressure gauge or a plug is mounted at the body side, while in case of A2 and B2, at the manifold side.

Note 2) Operation is possible with a valve with small Cv value when the operation cycle is small. 12 How to Order P B 1 3 1 3 A S Female thread / Tube extension P B 1 3 1 3 A S With nut Port size Material of diaphragm Symbol Main fluid Pilot air Symbol Material of diaphragm connection size connection size Female thread 1 PTFE 01 Rc 1/8 N01 NPT 1/8 F01 G 1/8 Actuation Tube extension Symbol