output P PNP open collector 1 output Symbol Description Nil Unit selection function1 M SI unit only2 P Unit selection function (Initial value psi)1 1 Under the New Measurement Act, switches with the unit selection function are not permitted for use in Japan. 2 Fixed unit: kPa, MPa y Option 2 t Option 1 r Piping specification Symbol Description Nil None Symbol Description Symbol Description
(Inch) 1/8" x 0.086" 1/8" 1/8" x 1/16" 3/16" 3/16" x 1/8" 1/2" 1/2" x 3/8" 3/8" 3/8" x 1/4" 1/4" 1/4" x 5/32" Refer to Best Pneumatics No. 7 for further details. 13 Series PB Applicable Fluids Material and Fluid Compatibility Check List for Process Pumps The data below is prepared based on data provided by the material manufacturers.
Dimensions 4 EXH port 1/8 Input signal port( PIL ) R port Supply pressure exhaust port 2 x 1/8 Output port 2( A ) Supply port on the other side 1( P ) 2 x M6 x 1 thread depth 8 (Panel mounting screw) Panel mounted Bracket mounted 2 x 6.5 hole (Mounting screw M6 x 1 x 12) Handle side 4 x M6 screw 4 x 7 hole on the bracket side Bracket plate thickness t = 2 Panel plate thickness t = 3 or less
B (3) (MPa) 3 OFF 1)4 1) OUT 0.7 0.6 VM1 VM1 () 0.5 0.4 0.3 0.2 ,0.6MPa VM2 VM2 0.1 ,0.3MPa 2 0 1 2 3 4 5 6 7 8 9 10 (m) 4 11 7. 4 (EXH) 1/8 (PIL) R 3 (R) 21/8 2 (A) 1 (P) 2M61 8 () 2x6.5 M6x1x12 4xM6 4X7 t=2 t=3 12 Revision history DVM VM100-A E (JIS) 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com
X201 R 1/8 NPT 1/8 None With seal Lead wire length 3 m Regulating pressure range 0.1 to 0.6 MPa Nil S X202 Lead wire length 3 m Regulating pressure range 0.1 to 0.6 MPa X215 16-9-1 2 Series IS1000 Construction 5 500 50 20 t u 0.1 0.2 y 0.3 0.4 i 58.5 MPa q Component Parts !
1 !2 t Component Parts Aluminum alloy NBR Note No. !0 Description Material No. PBT ADC Material Note q Description Black zinc chromated Metallic plated Pilot body Body Piston guide B Valve Metallic plated !1 !2 w e Return spring Cushion Cushion Valve spring Return spring Piston B Head cover r Stainless steel Spool/sleeve Stainless steel ZDC !3 Rubber t POM End cover !
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C4 [ø4 (5/32") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: T (Panel Mount Adapter for w/o Flow Adjustment Valve)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: T (Panel Mount Adapter for w/o Flow Adjustment Valve)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C4 [ø4 (5/32") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Panel Mount Adapter for w/o Flow Adjustment Valve
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Panel Mount Adapter for w/o Flow Adjustment Valve
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Lead Wire w/Connector (2 m), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: R (Bracket for w/o Flow Adjustment
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M)
25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication also on the sensor., Fast response: either 50 ms, 0.5s, 1,
(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: -, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence,
(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: -, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence,
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -