7 23 A B Hs 11.5 Hs CJ1 8.5 CJP 1 D-A7H D-A80H 7 22 A B Hs 10.2 A 36.7 B 16 D-C73C D-C80C CJ2 Hs CM2 8.5 10 13.3 13.3 CG1 A B 24 D-A73C D-A80C Hs 18.6 16 A 29 B MB D-H7 D-H7W D-H7BAL D-H7NF Hs MB1 CA2 8.5 1 7 23.5 A B D-A79W CS1 Hs 14 16 A 38.2 B D-H7C C76 C85 D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F 8.5 23 A B 1 C95 Hs 11 CP95 Auto Switch Mounting Position (mm) D-C7 D-C80 D-C73C D-C80C D-A73
RHC RZQ D-X Individual -X 961 Series REAS Auto Switch Proper Mounting Position (Detection at Stroke End) B A (mm) A dimension B dimension Auto switch model D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/F7WV D-F7BA D-F79F D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/FWV D-F7BA D-F79F D-F7NTL D-A73/A80 D-F7NTL D-A73/A80 Bore size (mm) 10 35 35.5 45 44.5 40.5
/A80 D-F7NTL D-A73/A80 D-F7NTL CY Bore size (mm) MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10 58 58.5 45 44.5 63.5 39.5 15 RHC 65 65.5 47 46.5 70.5 41.5 20 76 76.5 54 53.5 81.5 48.5 MK(2) 25 76 76.5 54 53.5 81.5 48.5 32 92 92.5 57 56.5 97.5 51.5 RS Q G
South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B 24 D-A73C D-A80C Hs 18.6 16 A 29 B MB D-H7 D-H7W D-H7BAL D-H7NF Hs MB1 CA2 8.5 1 7 23.5 A B D-A79W CS1 Hs 14 16 A 38.2 B D-H7C C76 C85 D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F 8.5 23 A B 1 C95 Hs 11 CP95 Auto Switch Mounting Position (mm) D-C7 D-C80 D-C73C D-C80C D-A73
Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy
CV/MVG wIf switches with an indicator light such as DA93(V) or D-A73(H, C) are used under a DC load, their polarities must be observed. The brown lead wire is positive (+) and the blue lead wire is negative (). The switches will operate even if the wires are reversed, but their LEDs will not illuminate.
Note 1) Lead wire length: Z (5m) applicable auto switches Reed: D-B53, D-B54, D-C73(C), D-C80C, D-A53, D-A54, D-A73(C)(H), D-A80C, D-Z73 Solid state: All types are produced upon receipt of order.
Applicable models: D-A73, A73H, A73C, C73, C73C, D-97, 93A, A93, A93V, D-A33A, A34A, A44A, D-B53, B54 2) However, in the case of a 2 color indicator type auto switch (D-A79W, B59W), note that the switch will be in a normally ON condition if connections are reversed. Never carry a cylinder by its lead wires.
Auto Switch Specifications Grommet Electrical entry: Perpendicular PLC: Programmable Logic Controller D-A7 (With indicator light) Auto switch model Applicable load Load voltage Load current range (3) D-A72 Relay, PLC 200 VAC 5 to 10 mA D-A73 Relay, PLC 24 VDC (4) 100 VAC 5 to 20 mA 5 to 40 mA e None 2.4 V or less Red LED illuminates when turned ON.
Auto switch type Model Features Electrical entry (Direction) Applicable bore size D-A72 D-A73 Grommet (Perpendicular) Without indicator light D-A80 D-A79W Diagnostic indication (2-color indication) Reed D-A73C Connector (Perpendicular) D-A80C Without indicator light D-A72H D-A73H, A76H Grommet (In-line) D-A80H Without indicator light 12 to 100 125 to 160 D-F7NV, F7PV, F7BV D-F7NWV, F7BWV
A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F P5DW 200 V A72 A73 A73C A79W F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV Grommet Yes 100 V 12 V Relay, PLC 2-wire 24 V Connector 12 V Diagnostic indication (2-color indication) Grommet 3-wire (NPN) 5 V, 12 V IC circuit 3-wire (PNP) Grommet 2-wire 12 V Connector Relay, PLC Yes 24 V 3-wire (NPN) IC circuit 5 V, 12 V Diagnostic output
Lead Wire Length Lead wire length designation (example) D-A73 L Lead wire length Nil L Z NNote) 0.5m 3m 5m None Note) Applies only to D C type connector switches.
Shock Absorber Seal Kits 6 NRB37-025 6 CY2S6-PS 10 NRB37-025 10 CY2S10-PS 15 NRB50-030 15 CY2S15-PS 25 NRB56-045 25 CY2S25-PS 32 NRB75-045 32 CY2S32-PS 40 NRB75-045 40 CY2S40-PS Note: Pre-wired Switches with 3/4 Pin Connectors available ACCESSORIES SERIES NCY2 A U T O S W I T C H E S Model Type Load Voltage Max Load Current and Load Current Range (mA) D-A72, D-A72H Reed 200VAC 5 ~10 mA D-A73
Applicable models: D-A93, A73(H)(C), A79W
D-J51: 5ms or less MHZ2 Lead Wire Length MHZJ2 How to specify lead wire length MHQ (Example) MHL2 L D-A73 MHR Lead wire length 0.5m 3m L 5m Z N MHK MHS None Applicable to only connector type switch D-C MHC2 Note 1) Lead wire length Z: 5m Applicable to Reed switch: D-B53/B54, D-C73 (C)/C80C, D-A73 (C) (H)/A80C MHT2 Solid state switch: Made to order (Except D-F9, F9lV, F7lWV) D-A53/A54, D-Z73
www.stevenengineering.com I FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N340 1.129 LINEAR ACTUATOR: SLIDE UNIT SERIES NCX2 ACCESSORIES AUTO SWITCHES ACCESSORIES APPLICABLE SHOCK ABSORBERS SERIES NCX2 Note: Pre-wired Switches with 3/4 Pin Connectors available, please consult SMC Customer Service Model Type Operating Voltage Maximum Current D-A73 200VAC 5 ~ 10mA
Bore size (mm) D-A73/A80 D-F7NTL Electrical entry (Fetching direction) D-F7NTL Solid state auto switch Type Model Features With timer Grommet (In-line) A B A B A B With pre-wired connector is available for D-F7NTL type, too.
angle projection] (Band mounting type) (Rail Mounting type) D-C7 D-C80 D-A7 D-A80 ( ): In case of D-A72 D-A7H D-A80H D-C73C D-C80C D-H7 D-H7W D-H7BAL D-H7NF D-A73C D-A80C D-H7C D-A79W D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F D-J79C Auto Switch Mounting Position (mm) D-A7H/A80H/A72 D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C/F7BAL D-F79F D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7 D-C80 D-C73C D-C80C D-A73
/Mounting Method Applicable cylinder -X2321/-X2322 -X2321/-X2322 -X2321/-X2322 Applicable auto switches D-P3DWAl D-M9lV/M9lWV D-A73/A79W Bore size [mm] 32 32 32 Auto switch mounting bracket part no.
Auto switch D-A73 CRB2 CRBU2 CRB1 23 (Perpendicular electrical entry) 8-M5 x 0.8 depth 6 (Opposite side 4 locations) MSU CRJ CRA1 Port size CRQ2 MSQ MRQ A port B port D20Foot style: CDRA1LW30 Mounting hole Auto switch D-A73 A port B port ( ) are the dimensions for rotation of 180.